Advertisement

Quick Links

■HOW TO OPERATE

◆H-75
①Loosen Knob and pull out Wire. (Do not pull out Wire any more if you find "red mark" on Wire.)
②Insert Wire to the pipe slowly and when Head reaches the blockage or Head cannot be inserted due to an
acute bend of the pipe, tighten Knob to hold Wire.
③Holding Grip by right hand, rotate Handle clockwise to clean the pipe.
④In case of heavy blockage, repeat to move Wire for and backward with rotating Handle clockwise and counter-
clockwise.
⑤When finished cleaning the pipe, pull back Wire to Wire Case with washing and spraying Wire with
anticorrosive oil.
(Optional Accessory : Rowonal R72142)
◆H-150
①Loosen Knob, pull up Chuck Handle to release Wire and pull out Wire. (Do not pull out Wire any more if you
find "red mark" on wire.)
②Insert Wire to the pipe slowly and when Head reaches the blockage or Head cannot be inserted due to an
acute bend of the pipe, push down Chuck Handle to hold Wire. Tighten Knob also when Wire cannot be held
by Chuck Handle.
③In case of heavy blockage, repeat to move Wire for and backward with rotating Handle clockwise and counter-
clockwise.
④When finished cleaning the pipe, pull back Wire to Wire Case with washing and spraying Wire with
anticorrosive oil.
(Optional Accessory : Rowonal R72142)

■HOW TO OPEN WIRE CASE

Wire Case can be opened when Wire is twisted in Wire Case or to clean the inside of Wire Case.
◆How to open
Loosen 4 pcs. of Stop Bolt A (Fig.1) and loosen 4 pcs. of Stop Bolt fixing Wire Case.
(Wire Case for H-75 is fixed with 3 pcs. of Stop Bolt.)
■HOW TO FIX HANDLE (H-150)
Insert Handle and tighten Stop Bolt with the attached
Allen Wrench.
Allen Wrench can be used to open Wire Case.
Stop Bolt
Handle
Fig.1
INSTRUCTION MANUAL
DRAIN CLEANER H-75
①Wire Case
②Knob
③Wire
④Grip
⑤Handle
CLASSIFICATION OF CAUTIONS
Warning : Indicates a potentially hazardous situation which, if not avoided, could result in death or serious
injury.
Caution : Indicates a potentially hazardous situation which, if not avoided, may result in minor or moderate
injury or damage to the machine.
IM801
DRAIN CLEANER H-150
①Wire Case
②Knob
③Head
④Chuck Handle
⑤Handle

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the H-75 and is the answer not in the manual?

Questions and answers

Subscribe to Our Youtube Channel

Summary of Contents for Asada H-75

  • Page 1 Loosen 4 pcs. of Stop Bolt A (Fig.1) and loosen 4 pcs. of Stop Bolt fixing Wire Case. ④Grip ④Chuck Handle (Wire Case for H-75 is fixed with 3 pcs. of Stop Bolt.) ⑤Handle ⑤Handle ■HOW TO FIX HANDLE (H-150)...
  • Page 2 ■SPECIFICATIONS 70135 Wire Key ● Code No. Item Capacity Length of Wire Weight ■SUITABLE SIZE OF HEAD (H-150) *For reference only DH75B Drain Cleaner H-75 Bulb 20~75mm φ8mm×8m(Bulb Head) 2.8kg Head 1”~ 1.1/4”~ 1.1/2”~ 2”~ 2.1/2”~ 3”~ DH75D Drain Cleaner H-75 Drop 20~75mm...

This manual is also suitable for:

H-150

Table of Contents