Download Print this page

Technical Data; Scope Of Delivery - PHYWE Cobra SMARTsense Oxygen Quick Start Manual

Advertisement

re and atmospheric pressure into
Take the temperatu
consideration.
hPa:
1026,5
1013,3
mmHg:
770
760
16°C
10.07
9.94
17°C
9.86
9.74
18°C
9.67
9.54
19°C
9.47
9.35
20°C
9.29
9.17
21°C
9.11
9.00
22°C
8.94
8.83
23°C
8.78
8.66
24°C
8.62
8.51
25°C
8.47
8.36
26°C
8.32
8.21
27°C
8.17
8.07
28°C
8.04
7.93
29°C
7.90
7.80
30°C
7.77
7.67
31°C
7.64
7.54
32°C
7.51
7.42
33°C
7.39
7.29
34°C
7.27
7.17
35°C
7.15
7.05
hPa:
959,9
946,6
mmHg:
720
710
16°C
9.42
9.29
17°C
9.22
9.10
18°C
9.04
8.91
19°C
8.86
8.74
20°C
8.69
8.57
21°C
8.52
8.40
22°C
8.36
8.25
23°C
8.21
8.09
24°C
8.06
7.95
25°C
7.92
7.81
26°C
7.78
7.67
27°C
7.64
7.54
28°C
7.51
7.41
29°C
7.39
7.28
30°C
7.26
7.16
31°C
7.14
7.04
32°C
7.03
6.93
33°C
6.91
6.81
34°C
6.80
6.70
35°C
6.68
6.59
5.5 Care
Membrane
Ensure not to damage the membrane and follow the storage
instructions in order to increase the service life of the elec-
trode. Creases or holes in the membrane are a sign that it
does not work properly any more.
If the membrane is soiled or if it shows signs of damage (this
might be indicated by incorrect measurement values), use a
spare cap with a membrane.
www.phywe.com, © All rights reserved
999,9
986,6
973,3
750
740
730
9.81
9.68
9.55
9.61
9.48
9.35
9.41
9.29
9.16
9.23
9.11
8.98
9.05
8.93
8.81
8.88
8.76
8.64
8.71
8.59
8.48
8.55
8.44
8.32
8.40
8.28
8.17
8.25
8.14
8.03
8.10
7.99
7.89
7.96
7.86
7.75
7.83
7.72
7.62
7.69
7.59
7.49
7.57
7.47
7.36
7.44
7.34
7.24
7.32
7.22
7.12
7.20
7.10
7.01
7.08
6.98
6.89
6.96
6.87
6.78
933,3
919,9
906,6
700
690
680
9.15
9.02
8.89
8.97
8.84
8.71
8.79
8.66
8.54
8.61
8.49
8.37
8.45
8.33
8.20
8.28
8.17
8.05
8.13
8.01
7.90
7.98
7.87
7.75
7.84
7.72
7.61
7.70
7.59
7.48
7.56
7.45
7.35
7.43
7.33
7.22
7.30
7.20
7.10
7.18
7.08
6.98
7.06
6.96
6.86
6.94
6.85
6.75
6.83
6.73
6.63
6.72
6.62
6.53
6.61
6.51
6.42
6.50
6.40
6.31
Cathode and anode
They must be polished with polishing cloths from time to time.
To do so, remove the cap so that the anode and cathode can
be accessed. Polish them with slight pressure and a clean
cleaning cloth in order to remove any deposits from the sur-
face. Rinse them with distilled water and then with alcohol,
shake the liquid off, and screw the cap back on loosely.
6

TECHNICAL DATA

Operating temperature range: 5 - 40°C
Rel. humidity < 80%
Oxygen in air:
Measuring range
Resolution
Accuracy
Oxygen in liquid:
Measuring range
Resolution
Accuracy (10~35°C)
Max. date rate
Battery capacity
Max. wireless range (open field)
Dimensions (length x width x height)
Weight
7

SCOPE OF DELIVERY

The extent of delivery is as follows
Cobra SMARTsense Oxygen
USB connecting cable type C
Dissolved and Air Oxygen Electrode
Operating instructions
8
ACCESSORIES
The following accessories are available:
Cobra SMARTlink
USB-charger
USB connecting cable type C
USB-Bluetooth-Adapter
Calibration solution Zero Oxygen, 500 ml
Software measureLAB
Free measureApp available from supplier portals
iOS
0...100 %
0...20 mg/l
0.01 mg/l
±0.5mg/L
85 x 40 x 23 mm
12933-01
07935-00
12999-99
07934-99
07935-00
07936-00
47072-50
14580-61
Android
Windows
12933-01 / 4521
0.1 %
±2%
10 Hz
250 mAh
30 m
40 g
4

Advertisement

loading

This manual is also suitable for:

12933-01