Cobra SMARTsense Oxygen
Fig. 1: 12933-01 Cobra SMARTsense Oxygen
1
SAFETY PRECAUTIONS
Caution!
Carefully read these operating instructions completely
before operating this instrument. This is necessary to
avoid damage to it, as well as for user-safety.
Only use the instrument for the purpose for which it was
designed.
Only use the instrument in dry rooms in which there is no
risk of explosion.
Protect the instrument from dust, moisture and vapours.
Use a slightly moist lint-free cloth to clean the instrument.
Do not use aggressive cleaning agents or solvents.
Take care that no liquid penetrates in through the hous-
ing openings, as such penetration would result in dam-
age to Sensor.
Do not open the unit.
2
PURPOSE AND CHARACTERISTICS
The sensor is used for measuring the gaseous oxygen con-
tent and the concentration of dissolved oxygen and for trans-
ferring the values to a terminal device, e.g. a tablet computer,
smartphone, etc., via Bluetooth or USB.
12933-01
1
12933-01 / 4521

Advertisement

loading

Summary of Contents for PHYWE Cobra SMARTsense Oxygen

  • Page 1 Internet www.phywe.com Operating instruc- tions The unit complies with the applicable EC-guidelines Fig. 1: 12933-01 Cobra SMARTsense Oxygen TABLE OF CONTENTS SAFETY PRECAUTIONS SAFETY PRECAUTIONS Caution! PURPOSE AND CHARACTERISTICS • Carefully read these operating instructions completely FUNCTIONAL AND OPERATING ELEMENTS before operating this instrument.
  • Page 2: Functional And Operating Elements

    M KCl). Ensure that no air bubbles are entrapped. The elec- trode comes supplied in an unfilled state. In addition, the liq- uid evaporates gradually. This is why the liquid must be topped up from time to time. www.phywe.com, © All rights reserved 12933-01 / 4521...
  • Page 3 Ensure that the water sample that is to be ana- prox. two minutes and the calibration can be performed. Set lysed is slightly stirred in a continuous manner. point 2 can be found in the table below. www.phywe.com, © All rights reserved 12933-01 / 4521...
  • Page 4: Technical Data

    If the membrane is soiled or if it shows signs of damage (this might be indicated by incorrect measurement values), use a spare cap with a membrane. www.phywe.com, © All rights reserved 12933-01 / 4521...
  • Page 5 CONFORMITY PHYWE Systeme GmbH & Co.KG hereby declares that the radio system type 12933- 01 complies with the 2014/53/EU directive. The complete text of the EC Declaration of Conformity is available at the following In- ternet address: www.phywe.com/en/ec-declaration DISPOSAL The packaging mainly consists of environmentally-friendly materials that should be returned to the local recycling sta- tions.

This manual is also suitable for:

12933-01