Page 2 · 286 TECMount User’s Manual Table of Contents Introduction ....................3 Installation and Use ................... 4 Mounting Plates ..................8 Connector Pin-Outs .................. 8 Using the Aux and Ext Sensor Inputs ............. 10 Technical Specifications ................. 11 Using the Thermistor on Standard Versions ........... 12 Using the RTD on 150°C Versions ............
The 286 TECMount comes standard with an integrated fan for additional cooling capacity. When used with the Arroyo Instruments TECSource temperature controllers, no additional power supply is needed to power the fan, or use a standard external 12V DC power supply when connecting to other temperature controllers.
Page 4 · 286 TECMount User’s Manual Installation and Use Consider how you plan to integrate the fixture into your application: Set it on your bench or optical table? Bolted to an optical table? Mount the cold plate horizontal or vertical? ...
Page 6
TECMount User’s Manual · Page 5 Bolting to an optical table This configuration is very similar to the one above, but instead of the feet, you will use the MB-286 base. Start with the MP-2.00 posts, threading them into the four 8-32 holes on the bottom of the fixture.
Page 7
The 286 uses a high volume fan for cooling of the heat sink. For full performance, you must place the sides and bottom of the 286 at least 2” away from any other surface, or airflow will be constricted. If you are using an Arroyo Instruments TECSource temperature controller, the...
Page 8
Mount setting in the menu to either 286 or 286-150, depending on which mount type you have, and the 5300 will be automatically configured for the mount. Where possible, we recommend the use of Arroyo Instruments TEC cables. When connecting to a 5300 Series TECSource, use p/n 1262-17W2.
Page 8 · 286 TECMount User’s Manual Mounting Plates The 286 TECMount is available in a standard bread board configuration with M3 holes on 10mm centers. Custom versions of the cold plate are available, contact the factory for details. Your 286 may be configured with a custom mounting plate, and if so, this manual should be accompanied by drawing for your plate.
Page 10
TECMount User’s Manual · Page 9 Temperature Controller Interface 17W2 Description TE – TE + Fan – / Interlock – TE – Fan + Aux Sensor + Interlock + (shorted to Interlock –) Aux Sensor – Vsense TE + EGND (Case) Sensor –...
Page 10 · 286 TECMount User’s Manual Using the Aux and Ext Sensor Inputs The 286 features a SENSOR switch to quickly switch between internal and external temperature sensors. With the SENSOR switch in the INT position, the internal thermistor or RTD embedded in the cold plate is used to provide the feedback for the temperature controller (pins 3 &...
TECMount User’s Manual · Page 11 Technical Specifications 286 TECMount COLD PLATE Standard Plates 286-01 Cold Plate Bread board, M3 holes, 10mm centers TEMPERATURE CONTROL Standard Version Temperature Range (°C) +15 to +85 Sensor Type BetaTHERM 10K3A1IA Sensitivity 10kΩ @ 25°C High Temperature Version Temperature Range (°C) +15 to +150...
Page 12 · 286 TECMount User’s Manual Using the Thermistor on Standard Versions The standard version of the 286 LaserMount is equipped with a 10kΩ negative temperature coefficient (NTC) thermistor, specifically, the BetaTHERM 10K3A1. A thermistor works by translating temperature into resistance, with resistance decreasing as temperature increases (hence the ‘negative coefficient’).
The coefficients for the BetaTHERM 10K3A1 thermistor are: A = 1.12924x10 B = 2.34108x10 C = 0.87755x10 These are the default coefficients for Arroyo Instruments temperature controllers. Using the RTD on 150°C Versions The 286-xx-150 LaserMount is equipped with a RTD sensor with a 0.00385 Ω / Ω...
Page 15
Page 14 · 286 TECMount User’s Manual For the Arroyo Instruments controllers that support RTD sensors, the default coefficients are different for this mount. They must be changed to use the 0.00385 Ω / Ω / °C curve, which has the following coefficients: A = 3.9080x10...
User’s Manual · Page 19 Warranty Arroyo Instruments warrants this product to be free from defects in material and workmanship under normal use and service for a period of one (1) year from date of shipment. It does not apply when the product has been misused, altered or damaged by accident or abnormal conditions of operation.