Summary of Contents for Trotec PCPC 10-1100

  • Page 1 PCPS 10-1100 ORIGINAL INSTRUCTIONS COMPRESSOR...
  • Page 2: Table Of Contents

    (e.g. material damage), but does not indicate hazards. Info Information marked with this symbol helps you to carry out your tasks quickly and safely. PCPS 10-1100 Follow the manual Information marked with this symbol indicates that the instructions must be observed. https://hub.trotec.com/?id=41525 compressor PCPS 10-1100...
  • Page 3: Safety

    General Power Tool Safety Warnings – Personal Safety safety General Power Tool Safety Warnings • Stay alert, watch what you are doing and use common Warning sense when operating a power tool. Do not use a Read all safety warnings, instructions, illustrations power tool while you are tired or under the influence of and specifications provided with this power tool.
  • Page 4 General Power Tool Safety Warnings – Power tool Device-specific safety warnings for compressors use and care and blow-out guns • Do not use the device in potentially explosive rooms or • Do not force the power tool. Use the correct power tool areas and do not install it there.
  • Page 5 • for measuring the current pressure level of an inflatable object • for generating compressed air for pneumatic tools whilst adhering to the technical data. Info Please note that the pressure gauge is not calibrated. We recommend using the power tool with original Trotec accessories. compressor PCPS 10-1100...
  • Page 6 Residual risks Note The device is not suitable for continuous operation. Warning of electrical voltage Over a period of 10 minutes, do not use the device for Electric shock from insufficient insulation. more than 1.5 minutes in continuous operation. Allow Check the device for damages and proper functioning the device to cool down for the remaining time.
  • Page 7: Information About The Device

    Information about the device Device description The compressor PCPS 10-1100 is suited for inflating bicycle tyres, car tyres, air mattresses as well as inflatable toys, sports equipment and beach items such as footballs or dinghies. The device is equipped with a 3 m compressed-air hose with quick coupling.
  • Page 8: Transport And Storage

    Technical data Transport and storage Parameter Value Note Model PCPS 10-1100 If you store or transport the device improperly, the device may be damaged. Max. pressure 8 bar (116 psi) Note the information regarding transport and storage of Max. air flow rate 10.8 m the device.
  • Page 9: Start-Up

    Disconnecting the compressed-air gun Start-up Warning Unpacking the device Risk of injury due to whipping compressed-air hose! • Take the device and the accessories out of the packaging. Disconnecting the compressed-air hose while the system is still pressurized can cause uncontrolled Warning of electrical voltage whipping of the compressed-air hose and lead to Electric shock from insufficient insulation.
  • Page 10 If you want to use the compressed-air gun with a Schrader Connecting the blow-out adapter valve, the compressed-air gun is already fully assembled and To remove dust and dirt in poorly accessible locations, use the can be directly connected using the quick-release lever (22). blow-out adapter (16).
  • Page 11: Operation

    Switching off the compressor Operation 1. Switch the device off by setting the on/off switch (2) to Tips and notes on handling the compressor position 0. General information: • Keep the venting slots clear to prevent the motor from overheating. • The device is not suitable for continuous operation. Over a period of 10 minutes, do not use the device for more than 1.5 minutes in continuous operation.
  • Page 12 Checking the pressure Deflating 1. Connect the compressed-air gun (12) to the compressor If the existing pressure is too high or if the desired pressure was (see chapter Connecting the compressed-air gun). exceeded during inflation, the excess air can be released. To do 2.
  • Page 13: Errors And Faults

    Should the device be overheating nonetheless, switch company or by Trotec. the device off and disconnect it from the mains. Light smoke or odour is emitted during the first use: Allow the device to cool down sufficiently before •...
  • Page 14: Maintenance

    • Allow the device to cool down completely. that apply for many EU countries on the website Warning of electrical voltage https://hub.trotec.com/?id=45090. Otherwise, please contact an Maintenance tasks which require the housing to be official recycling centre for electronic and electrical equipment opened must only be carried out by authorised authorised for your country.
  • Page 15: Declaration Of Conformity

    Declaration of conformity Declaration of conformity in accordance with the EC Machinery Directive 2006/42/EC, Annex II, Part 1, Section A We – Trotec GmbH – declare in sole responsibility that the product designated below was developed, constructed and produced in compliance with the requirements of the EC Machinery Directive in the version 2006/42/EC.
  • Page 16 Trotec GmbH Grebbener Str. 7 D-52525 Heinsberg +49 2452 962-400 +49 2452 962-200 info@trotec.com www.trotec.com...