6. Features 1. This product can quickly measure human body temperature through the forehead of the human body, with simple operation and fast measurement. 2. Type of protection against electric shock: Internal power supply equipment 3. Degree of protection against electric shock: BF applied part 4.
2. Function setting: 2.1℃ and ℉ temperature unit conversion Press the “ ” key to turn on / off, press the “℃ / ℉ ” key to enter the temperature unit conversion mode, and select “℃ or ℉ ”. 2.2 Conversion of body measurement and object measurement modes Press the “...
Page 22
Note: When measuring, you need to aim at the forehead, <5cm for temperature measurement. 2. Power-off If there is no operation after the measurement, the product will automatically shut down in about 60 seconds. 3. Cleaning and disinfection The product and its accessories cannot be autoclaved. Do not use strong acid or alkaline solution for disinfection.
Page 23
FAQ 1: The temperature cannot be displayed, and the full-screen display is repeated after booting. What is the cause? Answer: If this kind of problem occurs in the Infrared thermometer, it can be basically determined that the battery is low. You can try to replace the battery with a new one. FAQ 2: When some people's body temperature is measured in the same environment, if the screen displays "Lo", what is the reason? Answer: The possible causes to be excluded are as follows:...
FAQ 3: Is the product harmful to the human body and is it radiating to the human body? Answer: The principle of the product is to calculate the body temperature of the human body by collecting the infrared radiation of the human body. The product does not directly contact the human body and does not cause cross infection of different human bodies.
12. Cautions 1. Please read the instruction manual carefully before use. Improper use may cause loss of product performance and incorrect measurement values. 2. Other obstacles or local lesions at measured site such as inflammation, trauma, and postoperative will affect the accuracy of measurement. 3.
Direct current Handle with care AAA battery Keep away from sunlight Atmospheric pressure for Follow instructions for use storage Temperature limit for storage Humidity limit for storage Appliance compliance WEEE directive 14. Maintenance 1. Always keep the product surface clean and tidy, which will help prolong the service life of the product.
Annex: Guidance and manufacturer’s declaration – electromagnetic emissions WT-2 is intended for being used in the electromagnetic environment specified below. The customers or users of WT-2 should assure that it is used in such an environment. Emission test Compliance Electromagnetic environment –...
Page 28
Not applicable GB 17625.2 Guidance and manufacturer’s declaration – electromagnetic immunity WT-2 is intended for being used in the electromagnetic environment specified below. The customers or users of WT-2 should assure that it is used in such environment. Compliance Immunity test IEC 60601 test level Electromagnetic environment –...
Page 29
Portable and mobile RF communications equipment should not be used closer than the recommended separation distance to any part of WT-2, including cables. The separation distance should be calculated from the corresponding formula of transmitter frequency.
WT-2 is intended for being used in electromagnetic environment where radiated RF disturbance is controlled. As per the maximum power output of communication device, the customer or user of WT-2 can help to prevent electromagnetic interference by maintaining a minimum distance between portable and mobile RF communication device (transmitter) and WT-2 recommended below.
5. Equipment damage caused by user's improper transportation, storage or other reasons is not covered by the warranty. 6. If the warranty card does not have the seal of Woodpecker or the seal is incomplete, the warranty card is invalid.