Ortus GBD-R Operation Manual

Glass break detector

Advertisement

Quick Links

Attention! Reliability and life of the product are provided not only by the quality of product itself,
but also by the compliance with operating modes and conditions, therefore, this document require-
ments is mandatory
ORTUS Group
GBD-R
Glass Break Detector
GBD-R
Operation manual
Compatible radio receiver
Configuration Software
Central Monitoring Station
Version en_2
Product Compatibility Table
Configurator 11
Version
Lun-R
Version
Version
Orlan
1

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the GBD-R and is the answer not in the manual?

Questions and answers

Summary of Contents for Ortus GBD-R

  • Page 1 Attention! Reliability and life of the product are provided not only by the quality of product itself, but also by the compliance with operating modes and conditions, therefore, this document require- ments is mandatory Glass Break Detector GBD-R Operation manual Product Compatibility Table Version...
  • Page 2: Table Of Contents

    4. How to use..................................4 4.1. Modes Indication..............................5 4.2. Binding..................................5 4.3. Wireless signal strength............................. 6 4.4. Installing................................. 6 4.5. Adjusting................................. 7 5. Maintenance..................................7 6. Operating conditions..............................7 7. Storage....................................8 8. Transportation................................8 9. Disposal.................................... 8 GBD-R Version en_2...
  • Page 3: Purpose

    1. Purpose The GBD-R detector (hereinafter referred to as the “detector”) is designed to detect the break- ing/destruction of sheet glasses installed in the interior of protected objects and transmit this events to the Lun-R receiver that is connected to the Lun control panel (more about for compatibil- ity, see the documentation of the relevant control panel).
  • Page 4: How To Use

    ● If the voltage of the main battery drops to 2.3V or lower – the event "Main battery low" is generated; ● If the voltage of the backup battery drops to 2.3V or lower – the event "Bakup battery low" is generated; GBD-R Version en_2...
  • Page 5: Modes Indication

    6. Binding will processed automatically and, if successful, ends by turning on the red LED for 2…3 seconds (signal "Bound"). The detector waits 70 seconds for binding. To reinitialize the binding process, briefly close the RESET contacts again. GBD-R Version en_2...
  • Page 6: Wireless Signal Strength

    Use one of the holes in the wall tamper sensor. Drill holes in the wall according to the markup; 5. Fix the bottom of the detector housing in the selected place; 6. Install the detector PCB into the detector housing; 7. Close the detector housing with its cover. GBD-R Version en_2...
  • Page 7: Adjusting

    2. Detector shall be used at the temperature of –20°С to +55°С and relative humidity of 5% to 85%. 3. If the transportation conditions differ from the operating conditions, then the detector must be kept in the operating conditions for 2…6 hours before switching on. GBD-R Version en_2...
  • Page 8: Storage

    3. Transportation temperature shall be of –50°C to +50°C at the relative humidity of 5% up to 98%. 9. Disposal Detector disposal shall be carried out according to electronic household appliance disposal rules established by the legislation of the State, where the product is operated. GBD-R Version en_2...
  • Page 9 Manufacturer: ORTUS Group 1 East Liberty, 6th Floor Reno, NV 89501, USA Tel.:+1 650 240 27 62 mail: info@ortus.io http://www.ortus.io GBD-R Version en_2...