Preparations
1. Turn ON Receiver by pushing and holding Power button until sound
signal and turning ON the screen.
2. Put AA battery into transmitter, close the cap and wait for appearing
data on the screen.
3. Put the transmitter into the drill head (use adapter if needed) with
orienting on "12 o`clock" position. Put drill head in 3 meters from left
(right) side of the Receiver like on the picture below.
3m calibration
4. Press and hold
button to start calibration process. Keep holding
button press
button until 3.00 m numbers will appear. Unleash both
buttons.
5. CALIBRATION IS DONE
6. Clock position correction – correction clock face position of the drill
head on the screen. To make it – turn ON Receiver and transmitter,
put drill head with the transmitter in needed clock position, press and
hold
button and then press
button to confirm. New correction
can be done after canceling previous one. To cancel correction – turn
OFF the transmitter and make correction again. Position will back to
12 o`clock.