Advertisement

Quick Links

www.allstarlighting.com
3 CCT 2', 3', 4' T8
NOTE: This product complies with Part 18 of the FCC rules but may cause
interference to radios, tv's, wireless telephones and remote controls. If
interference occurs, move the product away from those devices or plug it into
a different outlet. Do not install this product near maritime safety communica-
tions equipment or other critical navigation or communication equipment
operating between 0.45-30Mhz.
NOTE: This equipment has been tested and found to comply with the limits
for a Class B digital device, pursuant to Part 15 of the FCC Rules. These limits
are designed to provide reasonable protection against harmful interference in
a residential installation. This equipment generates, uses, and can radiate
radio frequency energy and, if not installed and used in accordance with the
instructions, may cause harmful interference to radio communications.
However, there is no guarantee that interference will not occur in a particular
installation. If this equipment does cause harmful interference to radio or
television reception, which can be determined by turning the equipment off
and on, the user is encouraged to try to correct the interference by one or more
of the following measures: Reorient or relocate the receiving antenna,
Increase the separation between the equipment and receiver, Connect the
equipment into an outlet on a circuit from that to which the receiver is connected,
Consult the dealer or an experienced ratio/tv technician for help. This Class B
digital apparatus complies with Canadian ICES-005.
The units covered by this report were intended to retrofit surface mount with
diffuser for these models, Type IC or non-IC recessed mount listed fluorescent
luminaires that use maximum two tubular lamps, the minimum lamp
compartment dimensions are tabulated below:
Model
MINIMUM LAMP COMPARTMENT DIMENSIONS
LR34235
LR34233
LR34231

PARTS/COMPONENTS INCLUDED IN KIT:

- INSTALLATION INSTRUCTIONS
- LED TUBE LAMP
- LUMINAIRE MARKING LABELS. Only for Type B installation, please apply
the following lamp replacement label on the retrofit luminaire after the retrofit
kit has been installed, where readily visible by the user during relamping, and
after installation.

WARNINGS

TYPE A Application (PLUG & PLAY, Ballast compatible)
To avoid personal injury and/or possible product damage, the following
cautions must be followed:
• Read all safety information and instructions before installation.
• RISK OF ELECTRIC SHOCK. Disconnect power at fuse or circuit breaker
before installing or servicing.
• Suitable for damp locations - Not for use where directly exposed to water.
- CAUTION - DO NOT use with dimmers.
• This device is not intended for use with emergency exits.
• CAUTION - RISK OF FIRE. USE ONLY IN PLACE OF FLUORESCENT LAMPS
SPECIFIED ON PRODUCT LABEL.
• CAUTION - RISK OF FIRE - IF THE LAMP OR LUMINAIRE EXHIBITS UNDE-
SIRABLE OPERATION (BUZZING, FLICKERING, ETC.), IMMEDIATELY
TURN OFF POWER, REMOVE LAMP FROM LUMINAIRE AND CONTACT
MANUFACTURER.
I N S T A L L A T I O N G U I D E
LR34231, LR34233, LR34235
[Length x Width x Height][mm]
1218 x573 x 65
920 x 568 x 65
623 x 563 x 67
• CAUTION - RISK OF FIRE. IF LAMP DOES NOT LIGHT WHEN THE
LUMINAIRE IS ENERGIZED, REMOVE LAMP FROM LUMINAIRE AND
CONTACT LAMP MANUFACTURER OR QUALIFIED ELECTRICIAN.
• CAUTION - RISK OF FIRE OR ELECTRIC SHOCK. When working with
electronics ballast, please check compatible list first. If you do not find your
ballast on the list, then please bypass the fixture as TYPE B installation or
contact us for support. Do not install the LED tube with the ballast which not on
the ballast compatible list.
• To prevent damage to lamp, lamp must NOT be energized when color (CCT)
selector switch is changed.
WARNINGS
TYPE B Application (DIRECT WIRE, Ballast-Free)
To avoid personal injury and/or possible product damage, the following
cautions must be followed:
• Read all safe information and instructions before installation.
• RISK OF ELECTRIC SHOCK. Disconnect power at fuse or circuit breaker
before installing or servicing.
• To prevent damage to lamp, lamp must NOT be energized when color (CCT)
selector switch is charged.
• Suitable for damp locations - Not for use where directly exposed to water.
• CAUTION: DO NOT use with dimmers.
• This device is not intended for use with emergency exits.
• To prevent early lamp failure, lamp should only be installed in operating
environments ranging between: -4ºF and 113ºF ( -20ºC and 45ºC)
• WARNING - RISK OF FIRE OR ELECTRICK SHOCK. LED Retrofit Kit installa-
tion requires knowledge of luminaires electrical systems. If not qualified, do
not attempt installation. Contact a qualififed electrician.
Lamp
• WARNING - RISK OF FIRE OR ELECTRIC SHOCK. Install this kit only in the
Quantity
luminaires that have the construction features and dimensions shown in the
4
photographs and/or drawings and where the input rating of the retrofit kit does
4
not exceed the input rating of the luminaire.
• Do not make or alter any open holes in an enclosure of wiring or electrical
4
components during kit installation.
• WARNING - To prevent wiring diagram damage or abrasion, do not expose
wiring to edges of sheet metal or other sharp objects.
• Installers should not disconnect existing wires from lamp socket terminals to
make new connections at lamp socket terminals. Instead, installer should cut
existing lamp socket leads away from the lamp socket and make new electrical
connections to lamp socket lead wires by employing connectors suitable for
the application.
• THIS RETROFIT KIT IS ACCEPTED AS A COMPONENT OF A LUMINAIRE
WHERE THE SUITABILITY OF THE COMBINATION SHALL BE DETERMINED
BY AUTHORITIES HVING JURISDICTION. PRODUCT MUST BE INSTALLED
BY A QUALIFIED ELECTRICIAN IN ACCORDANCE WITH THE APPLICABLE
AND APPROPRIATE ELECTRICAL CODES. THE INSTALLATION GUIDE
DOES NOT SUPERSEDE LOCAL OR NATIONAL REGULATIONS FOR
ELECTRICAL INSTALLATIONS.
• Examine all parts that are not intended to be replaced by the retrofit kit for
damage and replace any damaged parts prior to installation of the retrofit kit.
• The tube is installed as Type B, the luminaire, once modified as retrofit
fixture, will no longer operate fluorescent lamps.
• For a linear tubular LED lamp conversion, there shall be text or a diagram
showing how the supply connections were made to the lamp holders so the
correct connections will be made to the lamp when the lamp is installed or
replaced.
33 Randolph Ave. • Avenel NJ 07001 | 732-882-1500
1

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the LR34231 and is the answer not in the manual?

Questions and answers

Summary of Contents for Luxrite LR34231

  • Page 1 I N S T A L L A T I O N G U I D E 3 CCT 2’, 3’, 4’ T8 LR34231, LR34233, LR34235 NOTE: This product complies with Part 18 of the FCC rules but may cause •...
  • Page 2 www.allstarlighting.com I N S T A L L A T I O N G U I D E TYPE A - WIRING DIAGRAM IMPORTANT NOTES: • The tube can work with either single-ended power input or double ended power input, but when work with single-ended power input, need power input from the end WITHOUT CCT switch.
  • Page 3 www.allstarlighting.com I N S T A L L A T I O N G U I D E Single Ended Input (Type B) Double Ended Input (Type B) 4. Select the CCT Select the color temperature through the CCT switch on the LED lamp’s base. •...

This manual is also suitable for:

Lr34233Lr34235

Table of Contents