AEG CHDF 6260 Operating And Installation Instructions

Aeg ventilation hood user manual

Advertisement

CHDF 6260
DF 6260
Dunstabzugshaube
Afzuigkap
Hotte aspirante
Cooker Hood
Montage- und Gebrauchsanweisung
Installatie- en gebruiksaanwijzing
Manuel de montage et d'utilisation
Operating and Installation Instructions

Advertisement

Table of Contents
loading

Summary of Contents for AEG CHDF 6260

  • Page 1 CHDF 6260 DF 6260 Dunstabzugshaube Afzuigkap Hotte aspirante Cooker Hood Montage- und Gebrauchsanweisung Installatie- en gebruiksaanwijzing Manuel de montage et d’utilisation Operating and Installation Instructions...
  • Page 2: Table Of Contents

    Contents Safety warnings for user for kitchen unit installer Introduction Extractor version Filter Version Description of the appliance Hood Operation Maintenance and care Metal grease filter Open the metal grease filter Carbon filter Changing the light bulb(s) Cleaning Special accessories Technical assistance service Guarantee conditions Technic Details...
  • Page 3: Safety Warnings

    Safety warnings for user • Always cover lighted elements, to prevent excess heat from damaging the appliance. In the case of oil, gas and coal fired cookers it is essential to avoid open flames. • Also, when frying, keep the deep frying pan on the cooker top/ cooker under careful control.
  • Page 4 • When the unit is used in its extractor version, a sufficiently large ventilation hole must be provided, with dimensions that are approximately the same as the outlet hole. • National and regional building regulations impose a number of restrictions on using hoods and fuel-burning appliances connected to a chimney, such as coal or oil room-heaters and gas fires, in the same room.
  • Page 5: Introduction

    (special accessory). • You will need original AEG carbon filter KLF 60/80 for this function (see Special Accessories). • In this version fumes are extracted to the outside via a hose.
  • Page 6: Hood Operation

    Hood Operation • The switches are arranged on the upper right side of the vapour catcher. (Fig. 1 - E). The numbers and symbols have the following meanings (from left to right): = Continuously variable blower control = Intensive setting = Lighting = Lighting OFF = Lighting ON...
  • Page 7: Maintenance And Care

    Maintenance and care • The hood must always be disconnected from the mains power supply before beginning any maintenance work. Metal grease filter • The purpose of the grease filters is to aspirate grease particles which form during cooking and it must always be used, either in the external evacuation or internal recycling function.
  • Page 8: Carbon Filter

    • The activated carbon filter should only be used if you want to use the hood in its filtering function. • To do this you will need an original AEG activated carbon filter (see special accessories). • Replacing the carbon filter The activated carbon filter must normally be replaced at least once every year.
  • Page 9: Changing The Light Bulb(S)

    Warning • Failure to observe the instructions on cleaning the unit and changing the filters will cause a fire hazard. You are therefore strongly recommended to follow these instructions. • The manufacturer declines all responsibility for any damage to the motor or any fire damage linked to inappropriate maintenance or failure to observe the above safety recommendations.
  • Page 10: Cleaning

    Cleaning • Warning: always disconnect the hood from the mains power supply before cleaning it. Never insert pointed objects in the motor’s protective grid. • Wash the outside surfaces using a delicate detergent solution. Never use caustic detergents or abrasive brushes or powders. •...
  • Page 11: Guarantee Conditions

    Guarantee conditions Guarantee Conditions AEG offer the following guarantee to the first purchaser of this appliance. 1. The guarantee is valid for 12 months commencing when the appliance is handed over to the first retail purchaser, which must be verified by purchase invoice or similar documentation.The guarantee does not...
  • Page 12 Before you move please contact your nearest Customer Care Centre, listed below, to give them details of your new home.They will then ensure that the local Service Organisation is aware of your move and able to look after you and your appliances. France Senlis Germany...
  • Page 13: Technic Details

    Technic Details Dimensions: Height x Width x Depht (in cm) Maximum absorbed power: Motor absorption: Lighting: Length of the cable: Mounting accessories included 1 Flange Ø 150 mm 1 Deflector 2 Wood-screws 2,9 x 22 mm 4 Wood-screws 4,5 x 16 mm 2 Metal-screws 3,5 x 9,5 2 Metal-screws 3,5 x 13 1 carbon filter frame...
  • Page 14: Electrical Connection

    Electrical connection Safety warnings for the electrician Before connecting the appliance to the power supply, check that the voltage indicated on the rating plate corresponds to the mains power supply available. Appliances fitted with a plug can be connected to any standard power socket within easy access.
  • Page 15: Installation

    Installation Preparing the wall unit - Extractor version • The hood is supplied as an extractor unit. Before installing the hood, drill a hole in the roof of the wall unit (see item. 5). This hole is to allow passage of the outlet pipe and the power cable, and to facilitate servicing.
  • Page 16 Outlet hole (extractor-filter version) • When used as an extractor unit, the hood must be fitted with a 150mm diameter hose. Fix the flange on the hood outlet hole, using 2 screws. Fig. 6a. Filter version only • Fix the deflector to the flange. Fig. 6b. Fig.
  • Page 17 Installing the fume extractor hood in the wall unit - extractor version (Filter version with carbon filter) • Apply the drilling template to the inside wall of the wall unit on the right and left sides, and mark out and predrill Ø 2 mm mounting holes as well as 2 x Ø...
  • Page 18 • If the cupboard is deeper than 300 mm, cover the gap between the hood and the wall with a finishing strip (special accessory). To install it, proceed as follows: Measure the wall distance and apply the covenng strip over the necessary width (wall distance plus 5 to 8 mm), kinking the covering strip at the appropriate notches and tearing off the surplus material (removing the protective foil).
  • Page 19 Removing the hood from the wall unit If, for technical reasons (extractor version/filter version conversion) the fume extractor hood has to be removed from the wall unit, proceed as follows: • Fully withdraw the vapour catcher and remove the grease filter. •...
  • Page 20 Installing the front panel (see also “Special accessories”) • Remove first the rear then the front grease filters. • Remove the internal cover pressing both unlocking devices (press and pull). Fig. 12. Fig. 15 • Predrill the front panel as per template and fix it to the vapour catcher with 3 screws.
  • Page 21 AEG Hausgeräte GmbH Postfach 1036 D-90327 Nürnberg http://www.aeg.hausgeraete.de © Copyright by AEG LI1SJB ed 01/02...

This manual is also suitable for:

Df 6260