Sealey MM19.V3 Quick Start Manual page 2

7-function multimeter

Advertisement

WARNING! NEVER apply voltage or current to the meter that exceeds the specified
maximum stated.
WARNING! USE EXTREME CAUTION WHEN WORKING WITH HIGH VOLTAGES.
2.
INTRODUCTION
High quality general-purpose multimeter with a large (46 x 25mm), clear and easy-to-read LCD display.
Supplied with test leads.
Measures:
- AC and DC Voltage
- DC Current
- Resistance
- Audible Continuity
- Diode/Transistor Verification Mode
3. SPECIFICATION
Model No: ...............................................................MM19.V3
AC Voltage (Accuracy): ............................. 200V, 750V (±2%)
DC Voltage (Accuracy):
............ 200mV, 2000mV, 20V, 200V (±1.5%), 1000V (±1.8%)
AC Current (Accuracy): ..................................................... No
DC Current (Accuracy):
.... 200µA, 2000µA, 20mA (±2%), 200mA (±2.2%), 10A (±2%)
Resistance (Accuracy):
............. 200Ω, 2000Ω, 20kΩ, 200kΩ (±1.8%), 2000kΩ (±2%)
Capacitance (Accuracy): ................................................... No
Temperature (Accuracy): ................................................... No
Frequency (Accuracy): ...................................................... No
Duty Cycle: ........................................................................ No
Continuity Audible: ........................................................... Yes
4. BATTERY INSTALLATION
WARNING! To avoid electric shock, disconnect the test leads from any source of voltage
before removing the battery cover.
4.2.1.
Disconnect the test leads from the meter.
4.2.2.
Open the battery cover by loosening the two cover screws using a cross head screwdriver.
4.2.3.
Insert the battery into battery holder, observing the correct polarity.
4.2.4.
Replace the battery cover. Secure with the screws.
WARNING! To avoid electric shock, do not operate the meter until the battery cover
is in place and fastened securely.
NOTE! If meter does not work properly, check the fuses and battery to make sure that
they are still good and that they are properly inserted.
5. FEATURES
Refer to diagram on right hand side
1. Function Switch
2. LCD Display
3. Common Jack
4. V.Ω.mA Jack
5. 10A Jack
NOTE: Fuse and battery compartment are at the rear of the unit.
Function
Range
200mV
2000mV
20V
DC Voltage
(V DC)
200V
1000V
OVERLOAD PROTECTION: 220Vrms AC for 200mV range and 1000VDC or 750Vrms AC for other
ranges.
200V
AC Voltage
750V
(V AC)
OVERLOAD PROTECTION: 1000 V DC or 750Vrms AC for all ranges.
RESPONSE: Average responding, calibrated in rms of a sine wave.
FREQUENCY RANGE: 45Hz - 450Hz
© Jack Sealey Limited
Resolution
100µV
1mV
±(1.5% reading + 2 digits)
10mV
100mV
1V
±(1.8% reading + 2 digits)
100mV
±(2% reading + 2 digits
1V
Original Language Version
2
1
Accuracy
(50/60Hz)
REMOVE SCREWS
TO ACCESS
BATTERY AND
FUSES
SYMBOLS AND ANNUNCIATORS
•)))
Continuity
Diode Test
Μ
Micro (amps)
M
Milli (volts, amps)
K
Kilo (ohms)
Ohms
DCV
Volts Direct Current
ACV
Volts Alternating Current
DCA
Amps Direct Current
HFE
Transistor Measurement
MM19.V3 Issue:6 (H,F) 21/10/21
5