Page 2
CONTRACT BETWEEN THE PARTIES. In no event will Eaton be responsible to the purchaser or user in contract, in tort (including negligence), strict liability or other-wise for any special, indirect, incidental or consequential damage or loss whatsoever, including but not limited to...
Page 3
A 2Mx bus, used to communicate with SAS application Sync A 2Mx bus used to communicate with the second 2Mx unit when PA/GA system is confi gured as A&B, AB+ or N+1 system SONIX HMI-5 TECHNICAL MANUAL TM373 / A June 2022 www.eaton.com...
This item is sold as a complete module therefore, no spares are necessary. this product reach you in an unsatisfactory condition please report this to Eaton to enable us to rectify and investigate the fault in a speedy manner. 1.2 Packaging In the interest of preserving the environment, Eaton aims to use recycled packaging wherever practical.
2.3.1 ATEX / IECEx Certification ATEX Certificate ITS 13 ATEX 27897 X Certified to EN 60079-0, EN 60079-11, EN 60079-26 IECEx Certificate IECEx ITS 13.0048X Certified to IEC 60079-0, IEC 60079-11, IEC 60079-26 SONIX HMI-5 TECHNICAL MANUAL TM373 / A June 2022 www.eaton.com...
2.0 Kg, 160 x 90 x 260 mm 3.2 Power and utility Voltage: 24 V dc phantom powered from partner equipment in the PA/GA system Current: 50 mA max consumption SONIX HMI-5 TECHNICAL MANUAL TM373 / A June 2022 www.eaton.com...
The Hand-held microphone hanger can be damaged by rough handling, take care when mounting the unit. 4.2 Glanding The Sonix Hmi-5 is typically supplied with 2 or more M20 tapped holes for cable gland terminations. Warning: Cable glands must be installed and inspected correctly to maintain Ex and IP ratings.
Hmi Tu (see Hmi Tu manual for details). 5.2 A & B duplication The Sonix Hmi-5 access panel is a duplicated unit with an A and B side. There is a small common section, namely Microphone, Buttons and indicators. The two...
5.4 Button and LED indicator operation Figure 5 - Button fl ap guard operation Each button on the Sonix Hmi-5 can be utilised to Warning: The standard Hmi-5 pushbuttons perform a pre-set function. The available functions are normally closed, open when activated, this discussed later in this section.
Associated Zone(s) are pre-selected by the local Fast flashing (5 Hz) panel (PTT not active) Associated Zone(s) are selected by the local panel Solid (may or not be broadcasting) SONIX HMI-5 TECHNICAL MANUAL TM373 / A June 2022 www.eaton.com...
System is busy with an Alarm, Routine or Solid Emergency speech loudspeaker(s). Typically, Local Attenuate will be implemented with a pre-set timeout window to prevent permanent latch up, values between 5 and 30 minutes. SONIX HMI-5 TECHNICAL MANUAL TM373 / A June 2022 www.eaton.com...
(see section 6.6.3), • the field. a priority set by the access panel/source (see section • 6.6.1), a zone map to define where the broadcast needs to • go (see section 6.6.2). SONIX HMI-5 TECHNICAL MANUAL TM373 / A June 2022 www.eaton.com...
Selection of a chime creates a delay between activating PTT and routing voice to the PA/GA system while the chime plays. SONIX HMI-5 TECHNICAL MANUAL TM373 / A June 2022 www.eaton.com...
The Mute output activates when the Hmi-5 is the active connected units. PTT broadcast on the PA/GA system. This approach allows the user to hear any overriding broadcasts if they are not the one active on the system. SONIX HMI-5 TECHNICAL MANUAL TM373 / A June 2022 www.eaton.com...
To read or change configuration or set the Unit ID, SAS installed on computer and Sonix data connection cable are required. Please see the SAS user manual for more details. SONIX HMI-5 TECHNICAL MANUAL TM373 / A June 2022 www.eaton.com...
Eaton representative for guidance on this matter. The LED indicators fitted to the Sonix Hmi-5 are long life units designed not to be replaced within the typical lifespan of the unit. If it becomes necessary to change...
DC input is into J5 (Phantom) b. Programming connector is J8 Warning: Programming firmware is potentially damaging to the unit if not performed correctly with Eaton tested and approved firmware. SONIX HMI-5 TECHNICAL MANUAL TM373 / A June 2022 www.eaton.com...
Page 21
Sonix Hmi-5 Technical Manual THIS PAGE IS INTENTIONALLY LEFT BLANK SONIX HMI-5 TECHNICAL MANUAL TM373 / A June 2022 www.eaton.com...
Page 22
All specifications, dimensions, weights and tolerances are nominal (typical) T: +44 (0) 1623 444 400 Printed in UK www.crouse-hinds.com/hac Publication No.TM373 / A and Eaton reserve the right to vary all data without prior notice. No liability is accepted for any consequence of use. MEDCSales@Eaton.com June 2022...
Need help?
Do you have a question about the SONIX Hmi-5 and is the answer not in the manual?
Questions and answers