Siemens LC68BUV50 User Manual And Installation Instructions page 7

Table of Contents

Advertisement

6.10 Switching off automatic mode
Press
​ ⁠ .
a The appliance starts at the previously selected fan
setting.
a The ventilation is automatically ended when the
sensor detects no further change in the room air
quality.
a Automatic mode runs for a maximum of four hours.
6.11 Sensor control
In automatic mode, a sensor in the appliance detects
the intensity of the cooking and roasting fumes. De-
pending on the setting of the sensor sensitivity, the op-
timum fan setting is automatically switched on. If the
sensor control system reacts too weakly or too
strongly, the setting for the sensor sensitivity may
change.
¡ Factory setting: 3
¡ Lowest setting: 1
¡ Highest setting: 5
6.12 Setting the sensor control
Requirement: The appliance is switched off.
Press and hold
​ ⁠ .
1.
a The setting is displayed after approx. one second.
To change the setting, slide your finger over the set-
2.
tings area
​ ⁠ .
Release
​ ⁠ to save the setting.
3.
6.13 Resetting the saturation indicator
After cleaning the grease filter or after changing the
odour filter, the saturation indicator can be reset.
Requirements
¡ After the appliance has been switched off,
pears in the display for the grease filter.
¡ After the appliance has been switched off,
pears in the display for the odour filter.
7  Home Connect
This appliance is network-capable. Connecting your ap-
pliance to a mobile device lets you control its functions
via the Home Connect app, adjust its basic settings
and monitor its operating status.
The Home Connect services are not available in every
country. The availability of the Home Connect function
depends on the availability of Home Connect services
in your country. You can find information about this at:
www.home-connect.com.
The Home Connect app guides you through the entire
login process. Follow the instructions in the Home Con-
nect app to configure the settings.
Tips
¡ Please consult the documents supplied by
Home Connect.
¡ Please also follow the instructions in the Home Con-
nect app.
1
Depending on the appliance specifications
1
1
​ ⁠ ap-
​ ⁠ ap-
Slide your finger to the left over the settings area
​ ⁠ .
a The saturation indicator is reset.
6.14 Setting the saturation indicator
The saturation indicator must be adjusted depending
on the filter used.
Requirement: The appliance is switched off.
Press and hold
​ ⁠ and
1.
To set circulating-air mode (non-regenerative fil-
ter), press ​ ⁠ .
To set circulating-air mode (regenerative filter),
press ​ ⁠ .
To set air extraction mode, press ​ ⁠ .
Release  ​ ⁠ and
​ ⁠ to save the setting.
2.
6.15 Switching on the lighting
The lighting can be switched on and off independently
of the ventilation system.
Press
​ ⁠ .
6.16 Setting the brightness
Press and hold
​ ⁠ until the required brightness is
reached.
6.17 Switching on the audible signal
Requirement: The appliance is switched off.
Press and hold
​ ⁠ and ​ ⁠ at the same time for ap-
prox. three seconds.
a ​ ⁠ appears on the display.
6.18 Switching off the signal tone
Requirement: The appliance is switched off.
Press and hold
​ ⁠ and ​ ⁠ at the same time for ap-
prox. 3 seconds until a signal sounds.
​ ⁠ appears on the display.
a
Notes
¡ Please note the safety precautions in this instruction
manual and make sure that they are also observed
when operating the appliance via the Home Con-
nect app.
→ "Safety", Page 2
¡ Operating the appliance on the appliance itself al-
ways takes priority. During this time it is not possible
to operate the appliance using the Home Connect
app.
¡ In networked standby mode, the appliance requires
a maximum of 2 W.
¡ If you need your device's MAC address to connect
to your home network, you can find this next to the
rating plate. → Page 11
Home Connect  en
​ ⁠ .
7

Advertisement

Table of Contents
loading

This manual is also suitable for:

Lc91buv50Lc91buv50bLc91buv50aLc91buv50iLc91buv55

Table of Contents