BM battery monitor manual TBB POWER CO., LTD.
Page 3
BM battery monitor manual WARNING : FIRE HAZARD SUITABLE FOR MOUNTING ON CONCRETE OR OTHER NON- COMBUS TABLE SURFACE ONLY CAUTION : THE DC AND AC BREAKER MUST HAVE BEEN TURNED OFF BEFORE SERVICING MADE IN CHINA TBB POWER CO., LTD.
General Description Thanks for choosing TBB product. The BM series battery monitor features microprocessor controlled combined with high resolution measuring system for Lead Acid battery voltage and charge/discharge current. With built in software, BM series can calculated consumed AH/KWH and remaining AH/KWH, and display battery voltage and battery current as well.
12V/24V system self-adaption for 48V system Available model Model Max Current Battery voltage comments BM100 100A 12Vdc/24Vdc 12Vdc/24Vdc self-adaption BM100S 100A 48Vdc BM200 200A 12Vdc/24Vdc 12Vdc/24Vdc self-adaption BM200S 200A 48Vdc BM400 400A 12Vdc/24Vdc 12Vdc/24Vdc self-adaption BM400S 400A 48Vdc TBB POWER CO., LTD.
Page 6
Optional DOD model: Compatible for 12Vdc 24Vdc 48Vdc RY50L 100A CR100L/RY100L CR100M CR100S 200A CR200LM CR200LM CR200S 400A CR400L CR400M CR400S Components Monitor Module Current Detector Module SS (for 100A,200A model) Current Detector Module SH (for 400A model) TBB POWER CO., LTD.
BM battery monitor manual Installation Preparation Material list TBB POWER CO., LTD.
Page 10
Screws for SS, M6 x 25mm Screws for monitor, M3x25mm Screw fixing expansion sleeve 4mm Connection cable between SS and battery negative, Cable-Flex-50/30 or Cable-Flex-25/30 Cable for starter battery, Cable-Starter-Batt‐Volt/01 Connection cable between SS and monitor, Cable-BM/03 TBB POWER CO., LTD.
Comm. port for battery energy information (black) Comm. for DOD Cable fastener Current Detector Module - SS Take off the cover, you will see the connector of the SS. Load - BM comm.Cable connector BAT- TBB POWER CO., LTD.
蓝 蓝 紫 紫 白 白 红 红 黄 黄 灰 灰 红 Starter-Batt+ 红 T4 Service-Batt+ To Connect to SS or SH To Port BM of the monitor module To connect Cable-Starter-Batt‐Volt/01 To connect Cable-Service-Batt-Volt/01 TBB POWER CO., LTD.
Page 13
T2: Starter Batt+ To Connect to Starter batt + To connect to Cable-BM/03 Cable-Flex-50/30 or Cable-Flex-25/30 Cable-Flex-50/30 and Cable-Flex-25/30 are to connect between battery negative connector and BAT- connector of current detector module (SS or SH). TBB POWER CO., LTD.
Page 14
Please make sure all of the equipments are powered off during the installation. The location of SS/SH is recommended to be as close as possible to the battery. Shorter cable between SS/SH and battery is better. TBB POWER CO., LTD.
BM battery monitor manual Monitor Module Mounting holder is optional accessary. Please consult to the distributor or TBB Power if you need Installation with the mounting holder 2 ‐φ 4 * φ 5 * 2 4 8 7 .6 ± 0 .5 0 2 ‐φ...
Page 16
1 0 0 A h B A T - 4 8 V /4 0 0 A h C a b le -F le x -5 0 /3 0 C a b le -F le x -2 5 /3 0 TBB POWER CO., LTD.
Page 17
1 0 0 A h 1 0 0 A h 1 0 0 A h 1 0 0 A h B A T - 1 2 V /4 0 0 A h D E V IC E - TBB POWER CO., LTD.
Page 18
Cable-BM/03 to complete the shut down of BM. b) If there is no starter battery connected, disconnect disconnect the cable connected to the service battery, Cable-Service-Batt-Volt/01 and Cable-BM/03 to complete the shut down of BM. TBB POWER CO., LTD.
Page 19
“Active Alarm” is ON, means the battery capacity correction is not completed. “Active Alarm” is flashing, means the battery capacity correction is completed with alarms. Please consult the technician. “Active Alarm” is OFF, means the battery capacity correction is completed successfully. TBB POWER CO., LTD.
Page 20
SOC: Battery State of Charge , 0%~100% Battery Monitor Voltage: Battery Voltage Current:Battery current. “-”means discharged current. Voltage 13.0V Without “-” means charging current. Current -2.0A Cycles: Battery cycles RE Time: Battery left to go. Cycles 65 Cycles RE Time 100Min TBB POWER CO., LTD.
Page 21
Battery Type Battery Capacity Battery Aging Rate Level <0.05%> <50AH> <50%> <3m> <AGM> Date Of Installation <60%> <01/01/2000> 02010306 Battery Rated Voltage <Auto Detect> 02010501 02010502 Common Addr Parity <0x70> <NONE> Comm Setting Baud Rate <9600> TBB POWER CO., LTD.
Date And Time Replace Battery: Set “Yes” for replacing the battery and doing the related 020103 setting for battery parameters. Replace Battery <No> 020104 Buzzer Beep Enable: “Enable” to forbid the buzzer beep. Buzzer Beep Enable <Disable> TBB POWER CO., LTD.
Default:01/01/2000, setting range 01/01/2000-31/12/2099。 02010303 Battery Aging Rate: Battery Aging Rate Permitted battery aging rate every year. <0.05%> Default is 0.05%, setting range 0.00%~5.00%. DOD : Depth of Discharge. <80%> Default is 75%. Setting range 50%~80%. TBB POWER CO., LTD.
Page 24
RS485 baud rate setting. <9600> Default is 9600. Setting range is 38400/19200/ 9600/4800/2400/1200. It is recommended to keep the default value. 02010502 Parity: Parity RS485 parity setting. <NONE> It can be set as ODD/EVEN/NONE. Default is NONE. TBB POWER CO., LTD.
Alarm #7 Event > Information Battery voltage low 040102 04010201 Alarm Logs Clear alarm Clear Alarm > <NO> P lease refer the below table for more details about the alarms in “Active Alarm” and “Alarm” of “Events”.(N=1~8) TBB POWER CO., LTD.
Page 26
Max Voltage Min SOC:The lowest SOC level in the day. 14.1V Max SOC:The highest SOC level in the day. Min Voltage :The lowest battery voltage in the day. Max Voltage:The highest battery voltage in the day. TBB POWER CO., LTD.
Page 27
Min SOC:The lowest SOC level in the month. Max Voltage 14.1V Max SOC:The highest SOC level in the month Min Voltage : The lowest battery voltage in the month Max Voltage:The highest battery voltage in the month TBB POWER CO., LTD.
34Cycles capacity. 04020401 040204 0402 Cycle 1 Recording Time Alarm Daily Logs Status 04/05/2015 History > Monthly Logs Setting 19:22:30 Total Logs Active Alarm Discharge Cycles Logs > Event > 1.42KWH,14% Information Clear History Charge 0.61KWH,6% TBB POWER CO., LTD.
Page 29
<No> Active Alarm Cycles Logs Event > Information Clear History > 04020501 Clear History: Clear History Clear all of the history records. <No> Information Softwave Version Status 00.01.0001 Setting Active Alarm Type BM100 Event Information > TBB POWER CO., LTD.
Current accuracy ±3% SOC accuracy ±5% Nominal switching 0.5A/30VDC Dry contact capacity protection Battery over voltage/Battery low voltage Other specification Communication RS485 -25℃ ~ 65℃ Working temperature Dimension (LxWxH) - 101*101*43.45 Height-g 500g IP protection IP32(Monitor)/IP10(SS100/SS100S/SS200/SS200S/SH400/SH400S) TBB POWER CO., LTD.