BluePass 2‐N‐1 Multi‐Tech Reader – Installation Guide 
820‐00001
 
This page is intended for installer use in the installation of the BluePass 2‐N‐1 Multi‐Tech Reader. 
 
Introduction 
This guide will walk a professional installer through the 
steps needed to attach a 2‐N‐1 BluePass Multi‐Tech 
Reader to an access control panel. The 2‐N‐1 supports 
125 KHz proximity fobs and cards as well as Linear 
BluePass mobile credentials. Please review the 
information below to ensure the reader is installed 
quickly and properly. 
WARNING:  DO NOT connect the reader up with 
energized wires until instructed to do so. 
Grounding 
The shield must run continuously from the reader to 
the panel. At the panel, the reader ground, shield 
line, and earth ground must be connected together 
at a single point.  
Do not ground the shield line at the 
o
reader end, as this will create a 
potential ground loop. 
Power 
A non‐switching power supply at the panel is 
recommended to power the reader for the highest 
noise immunity and best performance. 
For UL 294 Compliance, the readers shall be 
connected to a class two power limited power 
supply or control panel output. 
The recommended wire gauge is 24 AWG. 
Voltage 
The minimum reader voltage required is +6 VDC to a 
maximum of +16.0 VDC, and 12.0 VDC is 
recommended. 
The reader will require 100 mA (typical @ 12 VDC) in 
standard mode, 220 mA (typical @ 12 VDC) in 
advanced mode.  
The reader is in "standard" mode by default. 
"Advanced" mode can be configured via in‐app 
settings using the BluePass app. 
Copyright © 2018 Nortek Security and Control LLC
 
Connection 
Connections must be in accordance with NFPA 70. 
DO NOT connect to a receptacle controlled by a 
switch.  
Mounting the Reader 
If the unit is used to control a door or pedestrian 
gate, locate the unit as near as practical to the entry 
point. If the unit is mounted on or in a wall adjacent 
to the entry point, be sure the wall is sturdy. The 
repeated shock and vibration from a slamming 
access door or spring‐loaded pedestrian gate must 
be isolated from the unit.  
Never mount the reader directly on a moving door 
or gate. 
Choose a well‐lit location near the controlled 
opening. Wiring access for power, network, and 
earth ground must be available to the mounting 
location. 
Mounting 
Both the Mullion and Single‐gang readers can be 
mounted on a wall or any suitable flat surface. 
Mobile Device and Software 
The 2‐N‐1 Multi‐Tech Reader utilizes BLE version 4.0. 
The reader is to be used in conjunction with the 
BluePass Mobile App (Version 1.0 or higher).  
In order for the reader to function properly, the 
mobile device's software must be up to date. 
iOS Devices: iOS 10.0 or higher 
Android Devices: v5.0 (Lollipop) or higher and 
peripheral mode supported. 
Refer to http://bluepass.io or use the QR code 
for obtaining full versions of the User and 
Installation manuals. 
 
 
1
 
 
10020730 X5

Advertisement

loading

Summary of Contents for Nortek Security & Control Linear BluePass 820-00001

  • Page 1     BluePass 2‐N‐1 Multi‐Tech Reader – Installation Guide  820‐00001   This page is intended for installer use in the installation of the BluePass 2‐N‐1 Multi‐Tech Reader.    Introduction  Connection   This guide will walk a professional installer through the  Connections must be in accordance with NFPA 70.  steps needed to attach a 2‐N‐1 BluePass Multi‐Tech  DO NOT connect to a receptacle controlled by a  Reader to an access control panel. The 2‐N‐1 supports  switch.   125 KHz proximity fobs and cards as well as Linear  Mounting the Reader  BluePass mobile credentials. Please review the   If the unit is used to control a door or pedestrian  information below to ensure the reader is installed  gate, locate the unit as near as practical to the entry  quickly and properly.  point. If the unit is mounted on or in a wall adjacent  WARNING:  DO NOT connect the reader up with  to the entry point, be sure the wall is sturdy. The  energized wires until instructed to do so.  repeated shock and vibration from a slamming  Grounding  access door or spring‐loaded pedestrian gate must  be isolated from the unit.    The shield must run continuously from the reader to   the panel. At the panel, the reader ground, shield  Never mount the reader directly on a moving door  line, and earth ground must be connected together  or gate.  at a single point.   ...
  • Page 2     BluePass 2‐N‐1 Multi‐Tech Reader – Installation Guide  820‐00001       Reader Wiring    Wiegand  Conductor  Purpose  DC +6-16 VDC Red  Ground Black  Data 0 Green  Data 1 White  Red LED Purple  Beeper Orange  Card Present Yellow  Green LED Blue  Shield Ground Drain  Current Draw: 100mA (typical @ 12VDC)    UL 294 Performance Levels ...