GENERAL SAFETY INSTRUCTIONS (Cont'd)
1. The MX3030 Series' 30lb internal storage tank is designed to contain a maximum of 20.96 Lbs (9.52 Kg) of
refrigerant.
2. If this amount is exceeded, the user will be alerted and system operations will be halted.
3. Before normal operation can continue, the overfill condition must be remedied by moving refrigerant from the tank
to another storage tank or into a vehicle AC system. The charge function may be used to transfer internally stored
refrigerant to an external storage facility.
PRODUCT REGISTRATION
To register this MX3030 Refrigerant Management Machine for the MAXXAIR™ 1-2-3 product warranty, please visit
www.cpsproducts.com/hvac-warranty-registration/. Please contact us, if you have any technical issues during
registration of this machine.
You may also register this MX3030 Machine by using the touch screen (See Page 21).
AGENCY APPROVALS, STANDARDS, PATENTS
UL 1963 EEI Issued: 2013/10/11 Ed: 4 Refrigerant Recovery/Recycling Equipment
CSA C22.2 120 DEI Issued: 2013/03/01 Ed: 4 Refrigeration Equipment (R2018)
SAE J3030 Issued: July 1, 2015. Automotive Refrigerant Recovery/Recycling/Recharging Equipment Intended for
Use with Both R-1234yf and R-134a.
• This machine is covered under US Patent 8,082,750.
OVERVIEW
The MX3030 Refrigerant Management Center is for use with both R-134a and R-1234yf refrigerants and has been designed
for automotive technicians to easily Recover, Recycle, Evacuate and Recharge air conditioning systems in passenger vehicles
and light trucks. It features a seven inch, color touch screen display, a 30 Lb refrigerant tank, an oil-less compressor and
motorized ball valves.
Tank Overfill Limit
5
Need help?
Do you have a question about the MAXXAIR MX3030 and is the answer not in the manual?