Download Print this page

InterTest CN1 User Manual

Auto focus zoom ip cameras

Advertisement

Quick Links

User Manual
Firmware v1.2.0 based
Document Revision 1.3.1b

Advertisement

loading
Need help?

Need help?

Do you have a question about the CN1 and is the answer not in the manual?

Questions and answers

Subscribe to Our Youtube Channel

Summary of Contents for InterTest CN1

  • Page 1 User Manual Firmware v1.2.0 based Document Revision 1.3.1b...
  • Page 2 Disclaimer © 2013 All rights reserved. he trademarks of their respective owners. Information contained in this document may be superseded by updates. No representation or warranty is given and no liability is assumed by Technology with respect to the accuracy or use of the information, or infringement of patents or other intellectual property rights.
  • Page 3 INTRODUCTION FEATURES INTERFACE AND DIMENSION 18x / 33x Dimensions SYSTEM FUNCTIONS Overview System Initilize Zooming Focus Preset Auto Patrol Auto Scan Day & Night Setting White Balance AE (Automatic Exposure) AG (Automatic Gain) WDR (Wide Dynamic Range) Noise Reduction Color Enhancement Firmware Functionality SPECIFICATIONS TYPICAL INTEGRATION (PTZ DOME)
  • Page 4 his guide is for the use with the Auto focus IP Block Camera using firmware version 1.1.7 or above he User’s Manual provides functionality and instructions for the s which include the 10 / /33 based designed product series. Before Using the IP Block Camera Check the PC requirements &...
  • Page 5 FEATURES IP Block Camer the completed solution to provide real-time HD IP video with PTZ feature application. It offers highly-integrated block camera solution to take full advantage of high definition digital video, satisfying most surveillance PTZ-type camera application with quick, ultra low-cost and easy design-in features. esigned with industry state-of-the-art CMOS image sensor technology, performing high-quality image, full features and reliable AV streaming output;...
  • Page 6 INTERFACE AND DIMENSION Connector and Pin-define Name: Type: 16-pin 1.25mm pitch female wafer Definition: Pin Definition Pin_1 RS-485 + Pin_9 Pin_2 RS-485 - Pin_10 Line_Out Pin_3 UART_Rx Pin_11 Line_In Pin_4 UART_Tx Pin_12 Pin_5 External_IR_Sync._In Pin_13 Network_Tx+ Pin_6 External_IR_Sync._Out Pin_14 Network_Tx- Pin_7 Pin_15 Network_Rx+...
  • Page 7 Name: SD slot Type: microSD/SDHC Definition: Compatible micro- SD or SDHC card with class4 or class10, supporting up to 32GB capacity Locations of Controls Front: Lens Bottom: Tripod screw hole 18x / 33x ** When a tripod screw is used, please use 1/4 inch screw to attach it to the module;...
  • Page 8 Connector and Pin-define Name: Type: 16-pin 1.25mm pitch female wafer Definition: Pin Definition Pin_1 RS-485 + Pin_9 Pin_2 RS-485 - Pin_10 Line_Out Pin_3 UART_Rx Pin_11 Line_In Pin_4 UART_Tx Pin_12 Pin_5 External_IR_Sync._In Pin_13 Network_Tx+ Pin_6 External_IR_Sync._Out Pin_14 Network_Tx- Pin_7 Pin_15 Network_Rx+ DC6~12V Input + Pin_8 Pin_16...
  • Page 9 Name: SD slot Type: microSD/SDHC Definition: Compatible micro- SD or SDHC card with class4 or class10, supporting up to 32GB capacity Locations of Controls Front: Lens Bottom: Tripod screw hole 18x / 33x ** When a tripod screw is used, please use 1/4 inch screw to attach it to the module;...
  • Page 10: Pin Description

    Pin Description Pin_1 ~ Pin_2: RS-485 connection interface, controlling external motor module pan/tile movement Pin_3 ~ Pin_4: UART connection interface, communication with external camera for smart IR and ICR trigger; built-in VISCA protocol as default Pin_5: To receive high/low signal from external IR lighting module to trigger ICR switch at the same time Pin_6: To trigger with high/low signal to external IR lighting module...
  • Page 11 Dimension – 10 Front Right Rear Left Bottom...
  • Page 12 Dimension – Front Right Rear Left Bottom...
  • Page 13: System Functions

    SYSTEM FUNCTIONS Overview a professional IP block camera product, integrating superior HD CMOS sensor, high-quality auto-zooming lens and reliable streaming-application encoder design; it also equipped with state-of-the-art ISP (Image Signal Processing) engine to optimize video as clear, crystal at any surveillance environment System Initialize When module is power on, it will automatically manipulate system initialization including...
  • Page 14: Auto Patrol

    Manual Focus Mode The lens focus can be adjusted manually by slide bar on control panel of web client Focus adjustment speed can also be selected by client UI Auto Focus Mode An AF icon is located on control panel to allow user enable or disable auto focus function;...
  • Page 15: White Balance

    Force to Night Mode The built-in ICR will be always disabled to allow all light input, color mode or black/white mode can be selectable Auto Mode (AE) Mode Day or night mode will be decided by system analysis via entire captured image, user can also adjust “From day to night”...
  • Page 16 AE (Automatic Exposure): upports following AE (Auto Exposure) control modes: AE Range Limit This mode can define upper and lower exposure limit levels to allow system to automatically adjust image exposure within defined EV range **Upper limit range from 0.0EV to +2.0EV; lower limit range from 0.0EV to -2.0EV AEC(Auto Exposure Control) mode AEC mode can handle image exposure with maximum shutter time define;...
  • Page 17: Noise Reduction

    WDR (Wide Dynamic Range): The wide dynamic range can be set to be disable or enable with 3 different intensity **WDR level supports low, medium and high 3 levels setting 18x and 30x support dual-exposure WDR where image are produced by combining long-exposure and short-exposure one to obtain an high dynamic range image in which portions ranging from dark to light can be well-recognized Noise Reduction: The NR feature eliminates noise on image to provide clearer image quality...
  • Page 18: Firmware Functionality

    Firmware Functionality: Refer to “FIRMWARE MANUAL” document to get detail functionality description and example.
  • Page 19: Specifications

    SPECIFICATIONS Model Image Sensor 1/3” type CMOS Max. Resolution 2,048 x 1,536 (H x V) 10X Optical Zoom Lens: f=5.1 mm (WIDE) to 51 mm (TELE), F1.6 to F1.8 Lens 18X Optical Zoom Lens: f=4.7 mm (WIDE) to 84.6 mm (TELE), F1.6 to F2.7 33X Optical Zoom Lens: f=4.5 mm (WIDE) to 148.5 mm (TELE), F1.6 to F5.0 10X: 54.0º...
  • Page 20 Security Password Protection, IP Address Filtering, User Access Privilege TCP/IP, UDP, DHCP, HTTP, HTTPS, DNS, DynDNS, NTP, FTP, SMTP, UDP, RTP, Protocol RTSP, RTCP, 3GPP, UPnP, IPv4, SAMBA Client(NAS) ONVIF, CGI Intelligent Video Motion detection Alarm Trigger Periodical Timer, Intelligent Video, Network loss Intelligent Video, File Upload via FTP and E-mail, Notification via E-mail, File Recording Alarm Action to SD Card, Remote FTP or Remote NAS...
  • Page 21 TYPICAL INTEGRATIONS (PTZ DOME) 12~18 wire Slip Ring Pin Define Description # of pin Network Tx +/-, Rx +/- Net. Rx +/- Audio In/Out Net. Tx +/- Power Power supply Control UART or RS-485 Audio In Total 12 ~...
  • Page 22 APPENDIX: UART COMMAND Overview: For IR PTZ camera application, supports VISCA protocol for zoom position data output so that connected PT controller can manipulate smart IR control based on received position information; there are two modes supporting zoom position output: Zoom Position Info.
  • Page 23 36A4 3F38 3773 3F68 3836 3F94 38F0 **The default zoom position data table follow 36x SONY block cam model ICR Switch On/Off Alarm Receive By using external light sensor (ex. The built-in light sensor on PT camera), can switch ICR between day and night mode when receiving VISCA command as following: Protocol interface: UART (pin3 &...
  • Page 24 APPENDIX: BUILT-IN ENGINEERING PAGE Overview: To provide related parameters for allowing customers to configure for their own speed dome integration and verifying, a built-in ENGINEERING web page can be easily accessed via browser to satisfy this purpose and then be outputted as customization based information. All parameter value can be selectable or inputted and be immediately activated without system restart;...
  • Page 25 Description: Select Pelco D or Pelco P depending on your RS-485 connection protocol **Query Etrovision sales representative if more protocols need to be supported M-Flip / E-Flip Available value: Mechanical Flip / E-Flip Description: Select correct value depending on your PT camera flip type Mount Type Available value: Normal / Upside Down...
  • Page 26 via pin5 (refer to page of pin define) communication to make sure ICR within IPBC can be switched with PT camera at the same time iii. VISCA: Almost happen on PT camera using its light sensor to determine switching day/night mode; PT camera needs to trigger IPBC built-in ICR to set correct day and night mode.
  • Page 27 Baud Rates Second Sets – UART setting Available value: Baud rate / Data / Parity / Stop Description: Select correct value depending on your UART connection with PT camera Save Available value: Description: Click “Save” to active above parameters with new value Access built-in ENGINEERING PAGE –...
  • Page 28 Case A: PT camera supports proportional P/T Configuration example Enable “MCU Support Proportional” check box, input command value: 5 = Zoom Wide Speed Min (1 degree/s) 32 = Zoom Wide Speed Max (90 degree/s) Which are based on following speed table example ,then click save to activate **Zoom Wide Speed Table command...
  • Page 29 6 = Zoom Tele Speed Max (1 degree/s) Which are based on following speed table example , then click save to activate **Zoom Wide Speed Table command … … Speed °/s 0.1° 0.3° 0.5° 0.8° 1° 1.5° … 82° 94° …...
  • Page 30 Enable “Preset Points and Scan Limits Setting” check box, input command value How many preset points provide to use of your MCU? Description: Input exact number of pre-defined preset number for reserving them as specific functions Provide 2 preset points to control scan limit of area scan Description: Reserve 2 preset points from free range to be as “Scan Limit Left”...
  • Page 31 Provide 1 preset point to control scan start of panorama scan Description: Reserve 1 preset point from free range to be as “Scan Start” number Ex. reserve point 100 as scan start number How many preset points open to the public? Description: After define above numbers, system will automatically calculate available numbers of free preset points and list table which shows mapping relationship between user-used...
  • Page 32 Access built-in ENGINEERING PAGE – Scan Command Settings Allow IPBC to manipulate specific preset points or actions to perform related SCAN functionalities Enable “Scan Setting Control” check box, select desired action item for configuration Select Scan Action Available value: Scan Run Panorama (Speed Standard) Scan Run Panorama (Speed Low) Scan Run Panorama (Speed High) Scan Run Area (Speed Standard)
  • Page 33 Access built-in ENGINEERING PAGE – Export Config for Your Owned IPBC Firmware When finish all above parameter setting, remember to output 3 command URL and send back to can quickly integrate your parameter as your own firmware, contact sales representative to understand more detail information...
  • Page 34 DOCUMENT CHANGE LOG The following highlight document changes history. Document Version _________________________________________________________ Ver.: 1.3.1 Add built-in ENGINEERING PAGE description Ver.: 1.2.2 Modify dimension & weight Add CAM_VersionInq command Ver.: 1.2.0 Add B10 Ver.: 1.1.0 Add: VISCA ICR alarm Modified: Etrovision new template applied Ver.: 1.0.0 1st general release...
  • Page 35 Parameter description Load Defaults Available value: Description: Load back factory default value of all parameters **Useful when first-time access or drop modified parameter values RS-485 settings Available value: Baud rate / Data / Parity / Stop Description: Select correct value depending on your RS-485 connection of PT camera Protocol Available value: Pelco D / Pelco P...
  • Page 36 Flip Type Available value: Mechanical Flip / E-Flip Description: Select correct value depending on your PT camera flip type Mount Type Available value: Normal / Upside Down Description: Refer to following diagrams, select “Normal” or “Upside Down” depending on its physical mounting direction (face IPBC in front of it) Choose “Normal”...
  • Page 37 External Light Sensor In: the day/night mode switch is triggered by light sensor on PT camera , and be synchronized with via pin5 (refer to page of pin define) communication to make sure ICR within can be switched with PT camera at the same time VISCA: Almost happen on PT camera using its light sensor to determine switching day/night mode;...
  • Page 38 Select camera protocol depending on your PT camera setting; this is usually be used on UART communication with Camera version query, ICR trigger, external IR lighting control (ex. Use Sony when you desire to use VISCA) Sony blockcamera model name Available value: FCB-xxxxxxxxxxxxx Description:...
  • Page 39 Access built-in ENGINEERING PAGE – Movement Speed Settings When completing general settings, you will see and be allowed to set movement speed settings, this is especially for proportional P/T function...