Version 1.0, March 2020 The material contained in this manual consists of information that is the property of Evertz Microsystems and is intended solely for the use of purchasers of the 570FEC-HW-X19 product. Evertz Microsystems expressly prohibits the use of this manual for any purpose other than the operation of the 570FEC-HW-X19 product.
Page 3
IMPORTANT SAFETY INSTRUCTIONS The lightning flash with arrowhead symbol within an equilateral triangle is intended to alert the user to the presence of uninsulated “Dangerous voltage” within the product’s enclosure that may be of sufficient magnitude to constitute a risk of electric shock to persons. The exclamation point within an equilateral triangle is intended to alert the user to the presence of important operating and maintenance (Servicing) instructions in the literature accompanying the product.
Page 4
WARNING Changes or Modifications not expressly approved by Evertz Microsystems Ltd. could void the user’s authority to operate the equipment. Use of unshielded plugs or cables may cause radiation interference. Properly shielded interface cables...
Page 5
Evertz products are for informational use only and are not warranties of future performance, either expressed or implied. The only warranty offered by Evertz in relation to this product is the Evertz standard limited warranty, stated in the sales contract or order confirmation form.
Page 6
570FEC-HW-X19 Bulk 10GE FEC Encode/Decode This page left intentionally blank Page - ii Revision 1.0...
570FEC-HW-X19 Bulk 10GE FEC Encode/Decode OVERVIEW The 570FEC-HW-X19 platform is ideal for bulk FEC insertion and correction, offering flexibility with 3 modes of operation. The first mode features bi-directional operation featuring up to 32x bi-directional processing flows. This mode will allow RTP and FEC insertion for up to 32x IP paths. FEC correction along with Multi-path Packet Merge will be applied for 32x processing paths.
Refer to Figure 2-1 for 570 FEC-HW-X19 Front plate layout. Figure 2-1: 570FEC-HW-X19 Front Plate The front plate of 570FEC-HW-X19 has 4 available SFP slots. These SFP slots can be populated with SFP10G-TR13-A. This will allow 10G interface to the 570FEC-HW-X19 Encoder and Decoder.
Insert the rear panel into the back of the chassis and secure using the four screws provided. Now insert the 570FEC-HW-X19 card into the corresponding front slots ensuring the card lines up with the slot runners on the bottom and the top of the chassis. Push the card firmly into the slot ensuring that when it mates with the rear card it has been firmly pushed into a seated position.
570FEC-HW-X19 Bulk 10GE FEC Encode/Decode SPECIFICATIONS 3.1. INPUTS AND OUTPUTS Bi-directional Mode 64x IP inputs to allow for 32x processing paths of FEC insertion 32x IP outputs with FEC insertion FEC insertion Mode 96x IP outputs with FEC insertion*** FEC Correction Mode...
Page 14
570FEC-HW-X19 Bulk 10GE FEC Encode/Decode This page left intentionally blank Page - 6 Revision 1.0...
Bulk 10GE FEC Encode/Decode WEB INTERFACE The 570FEC-HW-X19 series of products are controlled using Web Interface. WebEasy operates using Ethernet and SNMP control protocols. After the card has been installed and configured with the required network addresses, it can be completely configured using the web interface.
Netmask: This Parameter allows the user to set the Netmask for control port. Gateway: This parameter allows the user to set the Gateway for control port. Please note the control port is only used when the 570FEC-HW-X19 is used in the S570FR. 4.1.3. Data Port Configuration For SFPP 1 to 4 IP Address: This parameter allows the user to set the IP address for data port.
570FEC-HW-X19 Bulk 10GE FEC Encode/Decode Figure 4-4: WebEASY® - System Section (Part 2 of 3) 4.1.4. Data Port Monitor For SFPP 1-4 Port Link Status: This parameter returns the link status for Data port. The status can be “Up” or “Down”.
570FEC-HW-X19 Bulk 10GE FEC Encode/Decode 4.1.5. SFP Monitor For SFPP 1-4 SFP Part Number: This field displays the part number of SFP. SFP Type: This field displays the type of SFP. SFP Rx Power Level: This field displays the Rx power level of SFP.
570FEC-HW-X19 Bulk 10GE FEC Encode/Decode 4.2. PRODUCT FEATURES Figure 4-6: WebEASY - Product Features Section ® 4.2.1. License Control Product Serial Number: This parameter displays the card’s serial number. Product Mac Address: This parameter displays the card MAC address. Page - 11...
570FEC-HW-X19 Bulk 10GE FEC Encode/Decode 4.3. FEC CORRECTION CONTROL Figure 4-7: WebEASY - FEC Correction Control Section (Part 1 of 3) ® 4.3.1. Main Input Port Control For FEC-Rx1 to FEC-Rx32 Input Stream Alias: This field allows the user to set the input alias name.
570FEC-HW-X19 Bulk 10GE FEC Encode/Decode 4.3.2. Backup Input Port Control For FEC-Rx1 to FEC-Rx32 Backup input Stream Alias: This field allows the user to set the back up input alias name. Backup SFP Port Selection: This dropdown allows the user to select the SFP where each channel will obtain their backup stream source from.
570FEC-HW-X19 Bulk 10GE FEC Encode/Decode MPPM Control For FEC-Rx1 to FEC-Rx32 Link Select: This dropdown allows the user to enable either Auto Packet Merge or select the port to receive data. Playout Delay: This field allows the user to set playout delay.
570FEC-HW-X19 Bulk 10GE FEC Encode/Decode Figure 4-9: WebEASY - FEC Correction Control Section (Part 3 of 3) ® 4.3.5. IP Bitrate Monitor For FEC-Rx1 to FEC-Rx32 Main Media Stream Bit Rate: This field reflects the main input stream bitrate. Main FEC Stream 1 Bit Rate: This field reflects the main input FEC stream 1 bitrate.
570FEC-HW-X19 Bulk 10GE FEC Encode/Decode 4.3.7. Settings Log Control Statistics: This button allows the user to choose whether or not to log statistics for this channel. The logs will be available via syslog. 4.4. FEC INSERTION CONTROL Figure 4-10: WebEASY - FEC Insertion Control Section ®...
570FEC-HW-X19 Bulk 10GE FEC Encode/Decode 4.4.1. Input Port Control For FEC-Tx1 to FEC-Tx32 Input Stream Alias: This field allows the user to set the input stream alias name. SFP Port Selection: This dropdown allows the user to select the SFP from which each channel will obtain their main stream.
570FEC-HW-X19 Bulk 10GE FEC Encode/Decode 4.5. SYSTEM NOTIFY Figure 4-11: WebEASY - System Notify Section ® 4.5.1. System Monitoring Control Temperature Warning Threshold: This field allows the user to set the temperature threshold for the overheat temperature. 4.5.2. System Notify System Traps: This control allows the user to turn traps On or Off.
570FEC-HW-X19 Bulk 10GE FEC Encode/Decode 4.6. FEC CORRECTION NOTIFY Figure 4-12: WebEASY - FEC Correction Notify Section ® 4.6.1. FEC Correction Alarm Control Uncorrected Packet Threshold: This field allows the user to set the error threshold before an alarm is sent.
570FEC-HW-X19 Bulk 10GE FEC Encode/Decode 4.7. FEC INSERTION NOTIFY Figure 4-13: WebEASY - FEC Insertion Notify Section ® 4.7.1. FEC Insertion Alarm Control RTP Sequence Error Threshold: This control allows the user to set a threshold for RTP Sequence Error.
570FEC-HW-X19 Bulk 10GE FEC Encode/Decode 4.8. SNMP SETUP Figure 4-14: WebEASY - FEC Insertion Notify Section ® 4.8.1. SNMPv1 Trap Destinations Add Trap Destination: This field allows the user to set an IP address for a new trap destination. IP Address: This field will display IP address for any currently set trap destinations.
Page 30
570FEC-HW-X19 Bulk 10GE FEC Encode/Decode This page left intentionally blank Page - 22 Revision 1.0...
570FEC-HW-X19 Bulk 10GE FEC Encode/Decode UPGRADE PROCEDURES 5.1. FIRMWARE UPGRADE Using the WebEASY on a web interface is the fasted and recommended way to load the firmware onto ® the 570FEC modules. On the top of the web page for the 570FEC modules, there is a button labelled Upgrade. The Upgrade tab is used to check current firmware version and upload the latest firmware (Figure 5-1).