Blacoh Spillstop Installation And Operation Manual

Blacoh Spillstop Installation And Operation Manual

Leak containment system
Hide thumbs Also See for Spillstop:

Advertisement

Quick Links

Installation and Operation Manual
When diaphragms fail in AODD pumps, dangerous process fluids are expelled from the pump's air exhaust
putting employees, equipment and the environment at risk. The fully pneumatic SPILLSTOP™ system prevents
the hazardous spill by safely capturing expelled fluid and automatically shutting down the failed pump. Optional
warning alarm and backup pump switchover further minimize system downtime for maximum productivity.
Visit
www.Blacoh.com
for literature online.

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the Spillstop and is the answer not in the manual?

Questions and answers

Summary of Contents for Blacoh Spillstop

  • Page 1 When diaphragms fail in AODD pumps, dangerous process fluids are expelled from the pump’s air exhaust putting employees, equipment and the environment at risk. The fully pneumatic SPILLSTOP™ system prevents the hazardous spill by safely capturing expelled fluid and automatically shutting down the failed pump. Optional warning alarm and backup pump switchover further minimize system downtime for maximum productivity.
  • Page 2: Table Of Contents

    Information in this document is subject to change without notice. No part of this publication may be reproduced, stored in a retrieval system or transmitted in any form or by any means electronic or mechanical, including photocopying and recording for any purpose other than the purchaser’s personal use without the express written permission of BLACOH Fluid Controls, Inc. BLACOH Fluid Control...
  • Page 3: Safety Warnings

    Temperature limit is determined by the liquid inside the SPILLSTOP and materials of construction. SPILLSTOP has no moving parts to generate heat. DO NOT use SPILLSTOP with incompatible fluids. Consult distributor or factory if you are not sure of the compatibility of fluids with SPILLSTOP.
  • Page 4: Installation & Operation Instructions

    Regulator. The quick connect can be removed for hard plumbing. 6. Adjust the Regulator to a minimum of 40 psi (2.7 bar) to start the pump. If the SPILLSTOP is installed with a Whistle and/or more than two Shutoff Valves, increase pressure to a minimum of 60 psi (4.1 bar).
  • Page 5: Service

    2. Test the Whistle before putting the SPILLSTOP into operation: a. Connect an air line to the Regulator and adjust the Regulator to a minimum of 40 psi (2.7 bar). If the SPILLSTOP is installed with more than two Shutoff Valves, increase pressure to a minimum of 60 psi (4.1 bar).
  • Page 6: Troubleshooting

    8. Disconnect all air supply to the pump and SPILLSTOP and reinstall the Pump Shutoff Valve. Verify that compressed air is supplied to Port A and that the pump’s air inlet is connected to Port B. Reapply compressed air to the SPILLSTOP to start the pump. If the pump does not operate normally, the valve may be undersized for the application.
  • Page 7: Typical Installation Diagram

    Figure 1 Typical Installation Diagram BLACOH Fluid Control...
  • Page 8: Pump Shutoff Valve

    Figure A 1 Pump Shutoff Valve BLACOH Fluid Control...
  • Page 9: Pump Shutoff Valve, 1 Exhaust Shutoff Valve

    Figure B 1 Pump Shutoff Valve, 1 Exhaust Shutoff Valve BLACOH Fluid Control...
  • Page 10: Pump Shutoff Valves

    Figure C 3 Pump Shutoff Valves BLACOH Fluid Control...
  • Page 11: Pump Shutoff Valves, 1 Exhaust Shutoff Valve

    Figure D 3 Pump Shutoff Valves, 1 Exhaust Shutoff Valve BLACOH Fluid Control...
  • Page 12: Manufacturer's Limited Warranty & Return Policy

    Manufacturer’s Limited Warranty & Return Policy Details regarding warranty and return policy are available on Blacoh’s website at www.Blacoh.com. PROUDLY MANUFACTURED IN THE USA Blacoh Headquarters 601 Columbia Ave, Bldg D, Riverside CA 92507 USA 951.342.3100 | www.Blacoh.com | Sales@Blacoh.com...

Table of Contents