Summary of Contents for Supertech agroline Farmpoint
Page 1
Farmpoint User Manual Instruction manual Bedienungsanleitung Notice d’utilisation Manuale di Istruzioni Gebruiksaanwijzing Bruksanvisning Instrucciones de uso Instrukcja obsługi Ver 1.1.0 Page 1/12...
Introduction Package Content Part Locator Keypad Instructions Prepare and Make a Measurement Adjusting the Calibration of the Meter Farmpoint Settings and Menu´s MEASURE BATTERY CLEAR AVERAGE CALIBRATION Some more valuable information about the moisture meter Using the averaging facility Battery...
User Information Warning/ Danger symbols used in this User Manual: These notes identify hazards which have a high probability of resulting in death or serious physical injury if not avoided. These notes identify hazards that can result in moderate or mild injuries if not avoided. These notes identify hazards associated with the risk of material damage.
It is an accurate instrument that provides consistent repeat readings when several samples are taken. The Farmpoint is made to ensure long durability and has a bright display for easy outdoor reading.
Instructions This section explains how to use the Farmpoint Prepare and Make a Measurement Inspect the two parts of the compression cell to make sure they are clean and empty. If the temperature of the grain sample differs a great deal from that of the meter, e.g. when taking measurements directly from the dryer, it is recommended to preheat the meter as follows: a.
2. Read the results on the result screen Adjusting the Calibration of the Meter Farmpoint is factory calibrated for every crop using the official methods of measuring moisture content as compiled by ISTA (International Seed Testing Association). The calibration scales are compiled using samples of crops grown in normal conditions.
8. An asterisk (*) will appear at the end of the name of the crop if adjustments have been made compared to the factory calibration. Farmpoint Settings and Menu´s The Farmpoint has a number of settings that can be reached by doing the following: 1. TURN ON DEVICE 2. Use the arrow-keys to choose between the menu settings...
CALIBRATION The calibration menu is used to recalibrate the meter. Differing growth factors between years and between varieties can have an effect on the electrical characteristics of the crop and it can therefore be necessary to recalibrate the meter. See page 7. Some more valuable information about the moisture meter Using the averaging facility...
Auto Turn OFF time - Setting Our Farmpoint is pre programmed to Turn-OFF after approximately 90 seconds of inactivity. If the device turns off by itself while using it please turn on the meter by pressing ON/TEST. Note: Due to different sized kernels one can expect slight deviations in the measurements since each sample will not be packed the same.
Quick Guide to Display Messages Symbol: Definition: Calibration has been adjusted from the factory setting for the crop being displayed. Temperature ++ Grain temperature is above the upper operating limit (50°C). Temperature -- Grain temperature is below the lower operating limit (0°C). Grain moisture content is above the upper limit (varies with crop).
Supertech Agroline Aps. Maltgørervej 7 5471 Søndersø, Denmark Declares Farmpoint to be in conformity with the requirements of the, Electromagnetic Compatibility (EMC Directive - 2014/30/EU and RoHS Directive - 2011/65/EU A signed Declaration Of Conformity document is available online at supertechagroline.com...