Contech Brooks Sho-Rate Series Installation & Operation Manual

Contech Brooks Sho-Rate Series Installation & Operation Manual

Glass tube variable area flow meters

Advertisement

Quick Links

Sho-Rate Series Models
1350G/1355G (Sizes 2-6)
Glass Tube Variable Area Flow Meters
Installation & Operation Manual
Sho-Rate
Model 1350G
(No Valve)
Sho-Rate
Model 1355G
(No Valve)
Av. Dr. Lino de Moraes Leme, 1.094 - Vila Paulista - São Paulo/SP
Telefone: (11) 5035-0920 - E-mail: orcamento@contechind.com.br
Sho-Rate
Model 1350G
with optional
integrated
flow controller
Sho-Rate
Model 1355G
with optional
integrated
flow controller
Sho-Rate
Model 1350G
with optional
needle valve
Sho-Rate
Model 1355G
with optional
needle valve

Advertisement

Table of Contents
loading

Summary of Contents for Contech Brooks Sho-Rate Series

  • Page 1 Sho-Rate Series Models 1350G/1355G (Sizes 2-6) Glass Tube Variable Area Flow Meters Installation & Operation Manual Sho-Rate Sho-Rate Sho-Rate Model 1350G Model 1350G Model 1350G (No Valve) with optional with optional integrated needle valve flow controller Sho-Rate Sho-Rate Sho-Rate Model 1355G Model 1355G Model 1355G (No Valve)
  • Page 2 Essential Instructions Read before proceeding! for local sales office contact information. Save this instruction manual for future reference. this warning can result in serious personal injury and / or damage to the equipment. result in serious personal injury and / or damage to the equipment. Connect all products to the proper electrical and pressure sources.
  • Page 3: Table Of Contents

    Contents Section 1 Introduction Description ..............................1 Specifications ..............................1 Optional Equipment ............................4 Section 2 Installation General..............................5 Receipt of Equipment ..........................5 Unpacking ..............................5 Return Shipment ............................5 Recommended Storage Practice ........................ 5 Installation ..............................6 Section 3 Operation Operation ..............................
  • Page 4 Figures 2- 1 Typical Flowmeter Installation ........................7 Dimensions - Sho-Rate 1350G ........................ 7 2- 3 Dimensions - Sho-Rate 1350G Panel Mount .................... .8 Dimensions - Sho-Ra te 1350G Bezel ......................8 Dimensions - Sho-Rate 1355G Panel Mount .................... . 9 Dimensions - Sho-Rate 1355G Bezel .......................
  • Page 5: Section 1 Introduction

    Section 1 Introduction Section 1: Introduction Description The Sho-Rate Flowmeters are variable area, glass tube, flow rate indicating meters. The basic elements are a tapered glass metering tube and a metering float. Features include quick and simple removal or installation of the tube and float while the meter remains in the process piping.
  • Page 6: Specifications For Sho-Rate Models 1350G And 1355G

    Section 1 Introduction Table 1-1 Specifications for Sho-Rate Models 1350G and 1355G Performance Av. Dr. Lino de Moraes Leme, 1.094 - Vila Paulista - São Paulo/SP Telefone: (11) 5035-0920 - E-mail: orcamento@contechind.com.br...
  • Page 7: Tube And Float Code - Eighth And Ninth Digit In Model Code For Scale Configuration

    Section 1 Introduction Table 1-2 Capacities - Rib Guide Tubes, Spherical Floats for use with 1350G Series Only Water Meter Tube Float Size Material SCFH NLPH Glass 0.010 0.041 0.12 Sapphire 0.021 0.079 0.19 R-2-65-A G Stainless Steel 0.049 0.18 0.37 Carboloy 0.10...
  • Page 8: Optional Equipment

    Section 1 Introduction Table 1-5 Capacities - Rib Guide Tubes, Spherical Floats for use with 1355G Series Only Meter Tube Float Maximum Flow Rate* Size Material Water (CC/Min) Glass 0.59 50 SCC/M Sapphire 79 SCC/M Stainless Steel 150 SCC/M R-2-15-AAAA G Carboloy 280 SCC/M Tantalum...
  • Page 9: Section 2 Installation

    Section 2 Installation Section 2: Installation General ® This section provides installation instructions for the Brooks Sho-Rate Models 1350G/1355G Flowmeters. Refer to Section 1 of this manual for connections. Receipt of Equipment When the equipment is received, the outside packing case should be checked for damage incurred during shipment.
  • Page 10: Installation

    Section 2 Installation Upon removal from storage, a visual inspection should be conducted to verify the condition of equipment is “as received”. If the equipment has been in storage for an excess of two (2) years or in conditions in excess of those recommended, all pressure boundary seals should be replaced and the device subject to a hydrostatic/pneumatic pressure test to 150% of rated pressure.
  • Page 11: Typical Flowmeter Installation

    Section 2 Installation HORIZONTAL VERTICAL LINE LINE FLOWMETER FLOWMETER A - Inlet Valve B - Outlet Valve C - Bypass Valve D - Control Valve E - Drain Valve Figure 2-1 Typical Flowmeter Installation It is recommended that a final leak test of the system plumbing and meter be performed before subjecting it to process fluid.
  • Page 12: Dimensions - Sho-Rate 1350G Panel Mount

    Figure 2-3 Dimensions - Sho-Rate 1350G Panel Mount Figure 2-4 Dimensions - Sho-Rate 1350G Bezel Av. Dr. Lino de Moraes Leme, 1.094 - Vila Paulista - São Paulo/SP Telefone: (11) 5035-0920 - E-mail: orcamento@contechind.com.br...
  • Page 13: Dimensions - Sho-Rate 1355G Panel Mount

    Figure 2-6 Dimensions - Sho-Rate 1355G Panel Mount Av. Dr. Lino de Moraes Leme, 1.094 - Vila Paulista - São Paulo/SP Telefone: (11) 5035-0920 - E-mail: orcamento@contechind.com.br...
  • Page 14: Dimensions - Sho-Rate 1355G Bezel

    Figure 2-7 Dimensions - Sho-Rate 1355G Bezel Av. Dr. Lino de Moraes Leme, 1.094 - Vila Paulista - São Paulo/SP Telefone: (11) 5035-0920 - E-mail: orcamento@contechind.com.br...
  • Page 15: Dimensions - Model 1350G/1355G With Flow Controller

    Figure 2-8 Dimensions - Model 1350G/1355G with Flow Controller Av. Dr. Lino de Moraes Leme, 1.094 - Vila Paulista - São Paulo/SP Telefone: (11) 5035-0920 - E-mail: orcamento@contechind.com.br...
  • Page 16: Section 3 Operation

    Section 3: Operation After the flowmeter has been installed in the flow system, it is ready for operation. An optional built-in needle control valve may be provided to control the flow through the flowmeter. These control valves are designed for fine control. Excessive tightening may damage the valve seat and limit its effectiveness as a control valve.
  • Page 17: Description

    Description T he Brooks bistable limit switches are inductive ring initiators designed to be slipped over the glass tube. The switch operates as a coil that is inductively a ctuated by a 316 Stainless Steel or Carboloy ball float. The limit switches can be set to any desired limit values, by sliding the switch along the metering tube.
  • Page 18: Power Supply/Relay Unit

    Power supply/relay unit P roximity switches may only be connected to a power supply/relay unit certified EEx ia IIB or EEx ia IIC, EEx ib IIB or EEx ib IIC. The switch adopts the same classification as the power supply/relay unit. The power supply/relay unit must fulfill NAMUR requirement, EN 50227 (DIN 19234).
  • Page 19: Alarm Settings

    Section 5: Alarm Settings Alarm Settings T he minimum setting distance of a switch and a fitting is 8 mm, and the minimum setting distance between 2 switches is approx. 30 mm, see figure 1. The standard alarm function is a bistable (latching) function, see figure 2. O nce the ball float moves inside the inductive switch, the alarm function is activated, it remains activited, even if the float continues to move towards the alarm zone, thus leaving the inductive switch.
  • Page 20: Section 6 Maintenance

    Section 6: Maintenance Disassembly and Cleaning It is recommended the user periodically inspect the tube and float, and clean if necessary. Dirt or foreign materials adhering to the tube and float may cause inaccuracy and sticking of the float. The metering tube (Borosilicate glass) and related parts may be cleaned with any solvent which does not attack glass.
  • Page 21: Reassembly Procedure

    Reassembly Procedure 1. Use the reverse of Steps 1 through 5 of the disassembly procedure to reassemble the meter. 2. Prior to installing the needle control valve assembly make certain that the valve stem is turned completely counterclockwise (full open position) to prevent damage to the valve seat.
  • Page 22: General

    Section 7: Parts List General When ordering parts please specify: Brooks Serial Number Model Number Part Number Description and Quantity (Refer to Figure 5-1 and Table 5-1) Av. Dr. Lino de Moraes Leme, 1.094 - Vila Paulista - São Paulo/SP Telefone: (11) 5035-0920 - E-mail: orcamento@contechind.com.br...
  • Page 23: Parts Drawing Sho-Rate Models 1350G And 1355G

    Figure 7-1 Parts Drawing Sho-Rate Models 1350G and 1355G Av. Dr. Lino de Moraes Leme, 1.094 - Vila Paulista - São Paulo/SP Telefone: (11) 5035-0920 - E-mail: orcamento@contechind.com.br...
  • Page 24 Table 7-1 Sho-Rate 1350G/1355G Parts List COMPONENT PART NUMBER for PART DESCRIPTION QTY. 1350G 1355G SEAL END FITTING Brass 325A110GGJ 325A110GGJ SS/STEEL Std Mat'l 325A109BMA 325A109BMA JACK PLUG Std Mat'l 817A088BMA 817A088BMA O RING (Jack Plug) Viton 375B012QTA 375B012QTA Buna 375B012SUA 375B012SUA Butyl...
  • Page 25 Table 7-1 Sho-Rate 1350G/1355G Parts List (Continued) COMPONENT PART NUMBER for PART DESCRIPTION QTY. 1350G 1355G ADAPTERS from End Fitting ( to 5/16-24 UNF ) **2 if no FCA, 1 if with FCA 2 or 1 NO P ART NO P ART NONE (integral 5/16-24 UNF Thds) TH'D -1/8"...
  • Page 26 Table 7-1 Sho-Rate 1350G/1355G Parts List (Continued) COMPONENT PAR T NUMBER for PART DESCRIPTION QTY. 1350G 1355G 20 INLET FLOAT STOP R-2-65-AG,BG,CG Std Teflon 846B141QMA R-2-65-DG Std Teflon 846B144QMA R-6-65-AG Std Teflon 846B147QMA R-6-65-BG Std Teflon 846B150QMA R-2-15AAAAG,AG,DG Std Teflon 846B143QMA R-2-15-BG,CG Std Teflon...
  • Page 27 Table 7-1 Sho-Rate 1350G/1355G Parts List (Continued) COMPONENT PART NUMBER for PART DESCRIPTION 1350G 1355G QTY. ADAPTER: Flow Controller to Cust Connection (1/4" M-NPT to) 1/8" (F) NPT 315T050BMA 315T050BMA 1/4" (F) NPT NO PART NO PART 1/8" Compression 320B209BMA 320B209BMA 1/4"...
  • Page 28 Table 7-1 Sho-Rate 1350G/1355G Parts List (Continued) VALVE O-RING MATERIAL TYPE SIZE BUNA VITON KALREZ EPR/EPM KALREZ/TEFLON BUTYL 947N091BMA 947N092BMA 947N095BMA 947N094BMA 947N096BMA 947N093BMA CARTRIDGE 3 947N097BMA 947N098BMA 947N101BMA 947N100BMA 947N102BMA 947N099BMA HIGH 947N103BMA 947N104BMA 947N107BMA 947N106BMA 947N108BMA 947N105BMA 947N063BNA 947N060BNA 947N064BNA 947N065BNA...
  • Page 29 Section 7 Parts List Table 7-1 Sho-Rate 1350G/1355G Parts List (Continued) Sho-Rate G Valve Sizing - AIR Sho-Rate G Valve Sizing - WATER Recommended Recommended Recommended Recommended Max Flow (SCCM Max Flow (GPH Tube/Float Valve (CART) (10 Valve (NRS) Tube/Float Valve (CART) (10 Valve (NRS) Air @ STP) Sho-...
  • Page 30 LIMITED WARRANTY Visit www.Br ooksInstrument.com for the terms and conditions of our limited warranty. BROOKS SERVICE AND SUPPORT Brooks is committed to assuring all of our customers receive the ideal flow solution for their application, along with outstanding service support to back it up. We operate first class repair facilities located around the world to provide rapid response and support.

This manual is also suitable for:

Brooks sho-rate 1350gSho-rate 1355g

Table of Contents