Summary of Contents for Charger HydroSplash CWISO475PA

  • Page 1 HydroSplash Reverse Osmosis Undersink Water Filtration System Owners Installation Manual Model: CWISO475PA/NF/CHPL...
  • Page 2 The Charger HydroSplash RO system is made with quality components to provide cleaner, safer drinking water. No chemicals are added or used in this system.
  • Page 3: Table Of Contents

    Table of Contents Notice Parts List 1.0 Introduction pg. 1 2.0 Installation pg. 2 2.1 Location of RO Unit pg. 2 2.2 Mounting the RO filter Unit Under a Sink pg. 3 2.3 Connecting the Feed Water Supply pg. 4 2.4 Installation of non UPC Drain Connection pg.
  • Page 4: Notice

    NOTICE This instruction manual was written to guide a professional plumber to make an easy installation of the Charger HydroSplash. The installation shall conform to state and local laws and regulations. This manual covers the HydroSplash system with 75 gallon per day membranes.
  • Page 5: Introduction

    1.0 INTRODUCTION The Charger HydroSplash is a 4 or 5-stage water cleansing system. The 5-stage system is identical to the 4-stage; with an additional carbon prefilter. For simplicity, this manual will be referencing the 5-stage system. The principle cleansing of the water of its dissolved solids is performed by the Reverse Osmosis membrane filter (Stage 4).
  • Page 6: Installation

    2.0 INSTALLATION Before starting the installation, you should measure the water pressure that is available under the sink to power the HydroSplash RO. If the pressure is less than 40-psig, it is too low; and if it is 90-psig, it may be too high. The solution if the pressure is too low is to use a model with a booster pump.
  • Page 7 Figure 1 Regular Clean Water Faucet Faucet Drinking Water Line from Post-Filter to Faucet (3/8” white tubing) Slip Joint AdapterI nstall Ball Valve UPC Approved Drain Connection Existing (Not included) Water Line Drinking Water Line to Storage Tank Drain Line (3/8”...
  • Page 8: Connecting The Feed Water Supply

    Connecting the feed water supply (Figure 3) The feed water assembly consists of 1/2” brass slip joint adapter, a black washer, and a 1/4" x 1/4" ball valve. Locate these parts in the installation kit. Locate the cold water shut off valve under the sink and turn it off. Open the cold water faucet to release the pressure.
  • Page 9: Installation Of Non Upc Drain Connection

    Installation of Non-UPC drain connection (Figure 4) Place the drain outlet saddle on the drain pipe. Allow proper space for the drilling operation. Tighten the saddle bolts evenly on both sides. Using the opening in the drain outlet saddle as a guide, drill a 1/4" hole in the drain pipe. Clean any debris out of the drain saddle connection.
  • Page 10: Porcelain/Enamel Over Steel Or Cast Iron Sinks

    Porcelain/Enamel over Steel or Cast Iron Sinks Using a small diameter carbide tipped drill, drill a pilot hole completely through the porcelain and the material underneath. Remove any metal chips that fall into the sink to prevent rust stains. Place the spring-loaded porcelain cutter bit in to the drill chuck.
  • Page 11: Install Faucet

    Install Faucet (Figure 6) Disassemble the hardware from the threaded stud except for the top base plate and sealing gasket. Install the faucet in the sink hole. From below the sink assemble the mounting hardware. Use a deep socket to tighten the nut. Figure 6 Escutcheon Plate Small Rubber Washer...
  • Page 12: Tubing Connections

    Tubing Connections (Figure 7) The standard tubing connections on the are of Quick HydroSplash Connect O-ring seal design and manufacture. Use the tubing and follow the instructions in Figure 8 to make the connections. If you cut the tubing, make sure it is a square cut and that the tubing fits evenly in the fitting and seals properly.
  • Page 13 Figure 7 Feed Water Line Connect the orange colored 1/4” inlet tubing to the ball valve, or saddle valve installed in Step 2.3 above. To reduce the water hammer effect on this fitting, make a large loop in the tubing before the connection on the sediment filter. To connect, remove compression nut insert tube over the ball valve tube as shown in Figure 3.
  • Page 14: Air Gap Faucet Installation

    Figure 8 Escutcheon Plate Small Rubber Washer Black Rubber Washer Counter Top Black Locating Washer Lock Washer 3/8” drain line from Airgap to Drainsaddle (blue) Faucet Adapter Drain line 1/4” from RO to Airgap (black) 3/8” Tubing (white) 2.9 Air-Gap Faucet Installation (Figure 8) Air-Gap Faucets are sometimes required by municipal code.
  • Page 15: System Start Up

    3.0 System Start-Up Air Purge The filter elements of stage 1, 2 ,3, and 5 filters as shipped are dry and contain air in the pores. The air will slowly be expelled but may collect in the system and will need to be purged for peak operating efficiency. Proceed with Section 3.2 for air purge and initial start-up procedure.
  • Page 16: Recommended Filter Changes

    At year 3 (or sooner if you have severe water problems), we recommend that the reverse osmosis assembly be changed also. When you order your third year kit from your Charger dealer, request the RO membrane assembly along with the other filters.
  • Page 17: Filter Replacement Procedure

    5.0 Filter Replacement Procedure The standard tubing connections on the Charger HydroSplash are of Quick Connect O-ring seal design and manufacture. Use the tubing and follow the instructions in Figure 8 to make the connections. If you cut the tubing, make sure it is a square cut and that the tubing fits evenly in the fitting and seals properly.
  • Page 18: Two-Year Limited Warranty

    100 lbs. per square inch. The warranty shall extend only to the original purchaser of the product from a Charger dealer for use by the purchaser. Any modifications of the product shall render the warranty invalid and Charger will have no further responsibility.
  • Page 19: Performance Data Sheet

    9.0 Performance Data Sheet Model CWISO475PA Contaminant Reduction Typical RO Influent Challenge Max permissible Minimum Average Substance Concentration product water Percent (%) Percent (%) mg/L concentration mg/L Reduction Reduction Arsenic (+5) 0.30 ± 10% 0.010 98.1 99.0 Barium 10.0 ± 10% 95.0 98.8 Cadmium...
  • Page 20: Arsenic Facts

    9.1 Arsenic Facts Arsenic (abbreviated As) is found naturally in some well water. Arsenic in water has no color, taste, or odor. It must be measured by a laboratory test. Public water utilities must have their water tested for arsenic. You can get the results from your water utility.
  • Page 21: Appendix A: Theory Of Operation

    Appendix A: Theory of Operation Flow Schematic Figure A-1 Pure Water Faucet Post Filter Clean Water Auto Valve RO Membrane Check Valve Discarded Water Clean Water Tank Bladder Feed Water Air Pressure Carbon Block Sediment Filter Filter A.1 Pre-Filters: The pre-filters have two purposes, one is to clean the water for better consumption, and the second is to prevent the RO membrane from being fouled.
  • Page 22: Auto Control

    generating pressure) to push the water molecules through the membrane, but keeping most of the dissolved solid molecules behind. The reverse osmosis technology will, on average, reject 93% of the total dissolved solids in the incoming water. Over time, the RO membrane will foul with a very thin layer of materials and the efficiency will drop, so that the TDS content of the clean water will rise.
  • Page 23 – 19 –...
  • Page 24 Charger Water Treatment Products • 8150 N. Lehigh Ave, Morton Grove, IL 60053 chargerwater.com...