Phoenix Contact Axioline P User Manual
Phoenix Contact Axioline P User Manual

Phoenix Contact Axioline P User Manual

Diagnostic registers and error messages
Hide thumbs Also See for Axioline P:

Advertisement

Quick Links

Axioline P diagnostic registers and error
messages
User manual
UM EN AXL P diagnostics

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the Axioline P and is the answer not in the manual?

Questions and answers

Summary of Contents for Phoenix Contact Axioline P

  • Page 1 Axioline P diagnostic registers and error messages User manual UM EN AXL P diagnostics...
  • Page 2 This user manual is valid for Axioline P products Designation Order No. AXL P BK PN AF 2316390 AXL P FBPS BASE 2316393 AXL P FBPS 28DC/0.5A 2316394 PHOENIX CONTACT GmbH & Co. KG • Flachsmarktstraße 8 • 32825 Blomberg • Germany phoenixcontact.com...
  • Page 3: Table Of Contents

    Intended use ..................3 1.3.2 Product changes ..................3 1.3.3 Terminology ................... 4 Diagnostics in the Axioline P system................... 5 Local diagnostics and status indicators ..............5 2.1.1 Indicators on bus couplers ..............6 2.1.2 Indicators on fieldbus power supplies ............ 8 Channel error types and DTM diagnostics.............
  • Page 4 Axioline P 2/16 PHOENIX CONTACT 4028_en_A...
  • Page 5: For Your Safety

    Field of application of the product 1.3.1 Intended use To provide information on Phoenix Contact Axioline P products within the PROFINET and PROFIBUS PA systems. 1.3.2 Product changes Changes or modifications to hardware and software of the device are not permitted.
  • Page 6: Terminology

    Part of the head of the Axioline station that is responsible for the controller of the Axioline P local bus Axioline P module Any module of an Axioline P station, i. e., head of the Axioline P station or I/O module 4/16 PHOENIX CONTACT 4028_en_A...
  • Page 7: Diagnostics In The Axioline P System

    About the fieldbus power supply Local diagnostics and status indicators All Axioline P modules are provided with diagnostic and status indicators for quick local error diagnostics. They enable the clear localization of system errors (bus errors) or fieldbus power errors.
  • Page 8: Indicators On Bus Couplers

    Axioline P 2.1.1 Indicators on bus couplers DIAG PRIM LNK1 LNK2 ACT1 ACT2 Figure 2-1 Indicators on the AXL P BK PN AF bus coupler Table 2-1 AXL P BK PN AF LEDs Label Color Description   Communication error (Bus Fault)
  • Page 9 Diagnostics in the Axioline P system Table 2-1 AXL P BK PN AF LEDs Label Color Description   Diagnostics DIAG Green on Run: Cyclic data exchange; status and data from the higher-level system is transmitted Green flashing Active: Configuration is active; data exchange with invalid process data;...
  • Page 10: Indicators On Fieldbus Power Supplies

    Axioline P 2.1.2 Indicators on fieldbus power supplies DC OK RDNT DC OK DC OK RDNT RDNT STATUS STATUS STATUS ERROR ERROR ERROR — — Figure 2-2 LEDs on the AXL P FBPS BASE and AXL P FBPS 28DC/0.5A Table 2-2 AXL P FBPS BASE and AXL P FBPS 28DC/0.5A LEDs...
  • Page 11: Channel Error Types And Dtm Diagnostics

    Diagnostics in the Axioline P system Channel error types and DTM diagnostics The AXL P... system is designed to include integrated physical layer diagnostics of the PROFIBUS PA segments in the FBPS plugs. These physical layer diagnostics can be interpreted through the LEDs on the FBPS plugs as well as in further detail in the DTM.
  • Page 12 Axioline P Table 2-4 DTM diagnostics for the Axioline P power supply (0x0140 … 0x0180) Channel error types and DTM diagnostics Type # Limit (if NE 107 state (0x0001... 0x001F & 0x0100... 0x7FFF) applicable) showing default Manufacturer specific alarms (0x0000 ... 0x007F) designation and Manufacturer specific DAP indexes (0x0000 ...
  • Page 13: Appendixes

    A Appendixes List of figures Section 2 Figure 2-1: Indicators on the AXL P BK PN AF bus coupler ........6 Figure 2-2: LEDs on the AXL P FBPS BASE and AXL P FBPS 28DC/0.5A .... 8 11/16 PHOENIX CONTACT 4028_en_A...
  • Page 14 Axioline P 12/16 PHOENIX CONTACT 4028_en_A...
  • Page 15: List Of Tables

    AXL P FBPS BASE and AXL P FBPS 28DC/0.5A LEDs ......8 Table 2-3: DTM diagnostics for the AXL P BK PN AF bus coupler......9 Table 2-4: DTM diagnostics for the Axioline P power supply (0x0140 … 0x0180) 10 13/16 PHOENIX CONTACT 4028_en_A...
  • Page 16 Axioline P 14/16 PHOENIX CONTACT 4028_en_A...
  • Page 17 The receipt of technical documentation (in particular user documentation) does not constitute any further duty on the part of Phoenix Contact to furnish information on modifications to products and/or technical documentation. You are responsible to verify the suitability and intended use of the products in your specific application, in particular with regard to observing the applicable standards and regulations.
  • Page 18 Middletown, PA 17057 Should you have any suggestions or recommendations for improvement of the contents and layout of our manuals, please send your comments to: tecdoc@phoenixcontact.com 16/16 PHOENIX CONTACT GmbH & Co. KG • Flachsmarktstraße 8 • 32825 Blomberg • Germany phoenixcontact.com...

Table of Contents