YTH WIRE MESH BUCKET
Operation and Maintenance Manual
This manual must be readily accessible to individuals
who actually use this product.
Improtant
Read this manual thoroughly prior to installing YTH wire mesh bucket.
Follow the instructions carefully for its correct and efficient installation
and operation.
This manual contains suggestions and instructions regarding the
specifications and installation of YTH wire mesh bucket.
The negligence of the instructions given in this manual may lead to
personal injury, cuts and equipment damage.
Keep this manual in a safe place
for future reference
1. Specifications
Model Number : YTH Wire Mesh Bucket 135A
Sieve mesh size : 50/100μm,
Model Number : YTH Wire Mesh Bucket 250A
Sieve mesh size : 50/100μm,
Model Number : YTH Wire Mesh Bucket 250B
Sieve mesh size : 250/500μm, Handling Capacity : 80L/min
Max. allowable pressure : 0.02 MPa
Compatible liquid : General water soluble coolant
* Allowable fluid temperature : 0ー50℃(as long as it doesn't freeze)
* For cast metals, select YTH Wire Mesh Bucket 250B.
2. Product Summary
The integrated structure of stainless wire mesh and bucket.
Dimensions and sieve mesh sizes
Handling Capacity : 40 L/min
Handling Capacity : 80L/min