Download Print this page

Lux Products TX500b Series Installation And Operating Instructions

Smart temp electronic thermostat

Advertisement

INSTALLATION AND OPERATING INSTRUCTIONS
TX500b SERIES
®
SMART TEMP
ELECTRONIC THERMOSTAT
MORN
MO
H
UP
E
DAY
A
EVE
T
NIGHT
PM
DOWN
SET
SET
WEEKDAY
SUNDAY
PROGRAM
PROGRAM
RESET
FAN
HEAT
AUTO
OFF
HOLD
ON
COOL
SET
RUN
DAY/TIME
NEXT
500
P a t e n t s P e n d i n g
SIMPLIFIED INSTRUCTIONS
TO SET PROGRAMS
TEMPORARY TEMPERATURE
TO SET TIME & DAY
• Rotate Dial to set DAY/TIME.
• Rotate Dial to SET
OVERRIDE
WEEKDAY
P
UP/DOWN t
Installs Easily
Set Day & Time
Complete, Easy To Read Programming And Installation Instructions
LUX PRODUCTS CORPORATION • Mt. Laurel, New Jersey 08054, USA
WARNING: Use Energizer
®
or DURACELL
Energizer
®
is a registered trademark of Eveready Battery Company, Inc.
DURACELL
®
is a registered trademark of The Gillette Company, Inc.
I M P O R T A N T !
Thank you for your confidence in our product. To obtain the best
results from your investment, please read this manual and acquaint
yourself with your purchase before installing your new thermostat.
Then follow the installation procedures, one step at a time. This
will save you time and minimize the chance of damaging the
thermostat and the systems it controls. These instructions may
contain information beyond that required for your particular instal-
lation. Please save for future reference.
FEATURES
• The TX500 can be used with most 24
volt gas, oil or electric heating and air
conditioning systems or gas millivolt
heating systems. It cannot be used
with 120 volt heating systems or heat
pumps. Ask your dealer for other LUX
thermostats to control those systems.
• The TX500 is programmable. There
are four programming periods per day.
Each period can be programmed
separately.
• You can use the built-in time/
temperature programs, or alter
them to suit your schedule. The
TX500 provides separate programming
for weekdays and weekends — for both
heating and cooling. You can override the
programmed temperatures for as little as one
programming period or for an entire vacation.
• In cool weather, when the system switch is set to HEAT, the TX500 will maintain cooler "set back"
room temperatures to save energy. It will then change to warmer "comfort" settings - all automatically, at
specified times during the day.
• In warm weather, when the system switch is set to COOL, the TX500 will maintain warmer "set back" room
temperatures to save energy. It will then change to cooler "comfort" settings - all automatically, at specified
times during the day.
• A large liquid crystal display shows time, day of the week, and room and set temperatures.
• 5/2 Minute Selectable Minimum Run/Off Time for Short Cycle/Compressor Protection.
• Two Energizer
or DURACELL
"AA" alkaline batteries (not included) are used to retain your time and
®
®
temperature programs.
WARNING: Use Energizer
C
A
U
• Your thermostat is a precision instrument. Please handle it with care.
• Turn off electricity to the appliance before installing or servicing thermostat or any part of the system.
Do not turn electricity back on until work is completed.
• Do not short (jumper) across electric terminals at control on furnace or air conditioner to test the
system. This will damage the thermostat and void your warranty.
• All wiring must conform to local codes and ordinances.
• This thermostat is designed for use with 24 volt and millivolt systems. The thermostat should be
limited to a maximum of 1.0 amps; higher amperage may cause damage to the thermostat. If you are
in doubt, call your utility company.
MORN
MO
UP
H
DAY
E
A
EVE
T
Easy as
NIGHT
PM
DOWN
SET
SET
WEEKDAY
SUNDAY
RESET
FAN
PROGRAM
PROGRAM
HEAT
AUTO
OFF
HOLD
ON
COOL
SET
RUN
DAY/TIME
NEXT
1–2–3
500
P a t e n t s P e n d i n g
SIMPLIFIED INSTRUCTIONS
TO SET TIME & DAY
TO SET PROGRAMS
TEMPORARY TEMPERATURE
• Rotate Dial to set DAY/TIME.
• Rotate Dial to SET
OVERRIDE
Choose Heat or Cool
®
Alkaline Batteries Only.
The Set Temperature
LUX
®
Speed Dial
Liquid
The Active
Crystal
Program Period
Display
UP
MO
MORN
H
E
DAY
A
T
EVE
NIGHT
PM
DOWN
SET
SET
WEEKDAY
SUNDAY
RESET
PROGRAM
FAN
PROGRAM
AUTO
HOLD
ON
SET
RUN
NEXT
DAY/TIME
500
P a t e n t s P e n d i n g
SIMPLIFIED INSTRUCTIONS
TO SET PROGRAMS
TEMPORARY TEMPERATURE
TO SET TIME & DAY
• Rotate Dial to set DAY/TIME.
• Rotate Dial to SET
OVERRIDE
• Press UP to change
WEEKDAY,
•Press UP/DOWN to
adjust set temperature.
current day.
SATURDAY or
•To clear OVERRIDE press
• Press NEXT.
SUNDAY PROGRAM.
• Press UP/DOWN to set time.
• Press UP/DOWN to
UP/DOWN until original set
adjust start time.
temperature appears or wait
• Press NEXT.
for the start tf the next period.
Rotate the
• Press UP/DOWN to
dial to
adjust temperature.
TEMPERATURE HOLD
the RUN
position
• Press NEXT.
• Press HOLD. Adjust temperature
to close
• Repeat as needed or
as desired with UP/DOWN.
the door.
rotate dial to RUN to
•To clear, press HOLD again.
stop Programming.
Thermostat Cover
®
or DURACELL
®
Alkaline Batteries Only.
T
I
O
© COPYRIGHT 2006 LUX PRODUCTS CORPORATION. ALL RIGHTS RESERVED
INSTALLATION
Please read all instructions carefully before
beginning installation.
TOOLS REQUIRED
#1 Phillips screwdriver (small)
3
Drill with
16
THERMOSTAT LOCATION
On replacement installations, mount the
new thermostat in place of the old one unless
the conditions listed below suggest otherwise.
On new installations, follow the guidelines listed below.
1. Locate the thermostat on an inside wall, about 5 ft. (1.5m) above the floor, and in a room that
is used often.
2. Do not install it where there are unusual heating conditions, such as: in direct sunlight; near a
lamp, radio, television, radiator, register, or fireplace; near hot water pipes in a wall; near a
52016
stove on the other side of a wall.
3. Do not locate in unusual cooling conditions, such as: on a wall separating an unheated room;
or in a draft from a stairwell, door, or window.
4. Do not locate in a damp area. This can lead to corrosion that will shorten thermostat life.
5. Do not locate where air circulation is poor, such as: in a corner or an alcove; or behind an
open door.
6. Do not install the unit until all construction work and painting has been completed.
7. This thermostat does not require leveling.
REMOVING THE OLD THERMOSTAT
Switch electricity to the furnace and air conditioner OFF; then
proceed with the following steps.
Fan Switch
System Switch
2. Note the letters printed near the terminals. Attach labels (enclosed) to each wire for identifi-
cation. Remove and label wires one at a time. Make sure the wires do not fall back inside
HEAT
the wall.
OFF
COOL
3. Loosen all screws on the old thermostat and remove it from the wall.
MOUNTING THETX500 ON THE WALL
Thermostat
Body/Sub-base
3. Press up on the button on bottom of thermostat and swing the body away from the base
and up to remove the body from the base.
C
Be careful not to drop the body or disturb electronic parts.
Leave the cover closed while the body is being removed
Base
N
Screw Anchors (2)
-in. (4.8mm) bit
1. Remove cover from old thermostat.
Most are snap-on types and simply
pull off. Some have locking screws
on the side. These must be
loosened.
3
1. Strip insulation
in.
8
(9.5mm) from wire
ends and clean off
any corrosion.
A
U
T
I
O
from the base.
Terminals
If you are mounting the base to a soft material
G
Y
W RH RC
like plasterboard or if you are using the old
mounting holes, the screws may not hold. Drill
a 3/16-in. (4.8mm) hole at each screw location,
and insert the plastic anchors provided. Then
Latch Button
C A U T I O N
To avoid electrical shock
and to prevent damage to
the furnace, air conditioner,
and thermostat, disconnect
the power supply before
OFF
beginning work. This can
be done at the fuse box, at
the circuit breaker, or at the
appliance.
C A U T I O N
Read instructions carefully
before removing any wiring
from existing thermostat.
Wires must be labeled before
they are removed. When
removing wires from their
terminals, ignore the color of
the wires since these may
not comply with the
standard.
2. Fill wall opening with
non-combustible
insulation to prevent
drafts from affecting
the thermostat.
N
N O T E
mount the base as described.

Advertisement

loading

Summary of Contents for Lux Products TX500b Series

  • Page 1 On new installations, follow the guidelines listed below. 1. Locate the thermostat on an inside wall, about 5 ft. (1.5m) above the floor, and in a room that is used often. 2. Do not install it where there are unusual heating conditions, such as: in direct sunlight; near a lamp, radio, television, radiator, register, or fireplace;...
  • Page 2: Wiring Diagrams

    Limited Warranty: If this unit fails because of defects in materials or workmanship WIRE IS FAN WIRE within three years of date of original purchase, LUX Products Corporation will, at its W RH RC option, repair or replace it. This warranty does not cover damage by accident, misuse, or failure to follow installation instructions.
  • Page 3: Setting The Time And Day

    5 minutes. You may change this minimum on/off time to 2 minutes. To accomplish this, place the jumper labeled JP3 over both pins. You must press the small reset button on the face of the thermostat for the changes to take effect.