  • Page 3 User Manual RCAD © 2016 by Vogel & Plötscher GmbH & Co. KG RCAD Version 2.0 25.01.2015...
  • Page 4: Table Of Contents

    5.2 Storage and transportation ....................16 5.3 Battery replacement ......................17 6. Technical data ........................18 6.1 RCAD – 1435 mm ......................18 6.2 RCAD – 1000 mm ......................19 6.3 RCAD – 1067 mm ......................20 6.4 RCAD – 1524 mm ......................21 ©...
  • Page 5 Page: 3 / 28 6.5 RCAD – 1668 mm ......................22 7. EC Declaration of Conformity ....................23 8. Miscellany ..........................24 9. Add-ons and options ......................25 9.1 Data storage and Bluetooth (= option -BT) ................ 25 9.2 Data storage on SD card (= option -SD) ................25 9.3 Switch tongue control adapter (option -P) .................
  • Page 6: Introduction

    § Cant § Depending on the technical design and configuration options, RCAD can be used to measure and record a range of different measurement variables. Data is acquired within the specified measuring ranges and tolerances (à chapter 6). Users must be properly trained and qualified to use the measurement device. Consequently, users are advised to undergo a practical induction course by V&P or someone authorised by...
  • Page 7: Functional Components

    The measurement device comprises the following functional components: Fig. 1: Designation Narrow support (moveable) Adjusting knob (incl. clutch-mechanism) Display with keypad Handle Base frame Wide support Battery box © 2016 by Vogel & Plötscher GmbH & Co. KG RCAD Version 2.0 25.01.2015...
  • Page 8 Background illumination will be enabled (disabled) if ON/OFF button is pressed again while device is already switched on. Activated background illumination of the display will stress the batteries and shorten operation time. © 2016 by Vogel & Plötscher GmbH & Co. KG RCAD Version 2.0 25.01.2015...
  • Page 9: Start-Up

    3. Start-up 3.1 Safety instructions RCAD is a state-of-the-art system, assuring a high degree of reliability. However, that reliability can only be attained in practice if all the necessary measures are taken. It falls within the duty of care of the company operating the measuring device to en- sure that those measures are taken, and to monitor their implementation.
  • Page 10: Checking Measurement Sensors

    à Fig. 2 Move narrow support all the way in à Fig. 3b Read off displayed actual value and compare against reference value Fig. 3a Fig. 3b © 2016 by Vogel & Plötscher GmbH & Co. KG RCAD Version 2.0 25.01.2015...
  • Page 11: Initialization Of Gauge Sensor

    The two recorded cant values are compared. The values should not differ by more than 1,0 mm, with an inverted preceding sign. In the event of a variation > 2 mm, the inclination sensor has to be initialized (à Section 3.3.4). © 2016 by Vogel & Plötscher GmbH & Co. KG RCAD Version 2.0 25.01.2015...
  • Page 12: Initialization Of Inclination Sensor

    In case the initialization procedure fails to deliver any improvement, the measuring device must be checked and recalibrated at the factory. Fig. 4a Fig. 4b © 2016 by Vogel & Plötscher GmbH & Co. KG RCAD Version 2.0 25.01.2015...
  • Page 13: Measurement Practice

    (à Fig. 5a | 5b). Fig. 5a: Fig. 5b: Legend Designation Wide measuring support Outer measuring probes Centre measuring probe (for measurements at check rail) © 2016 by Vogel & Plötscher GmbH & Co. KG RCAD Version 2.0 25.01.2015...
  • Page 14: Narrow Measuring Support

    (à Fig. 6). The final measuring position has been reached as soon as the clutch- mechanism of the turning knob contacts the stop (= loose rotation). Fig. 6: Legend Designation Adjusting knob (incl. clutch-mechanism) Narrow measuring support Measuring probe © 2016 by Vogel & Plötscher GmbH & Co. KG RCAD Version 2.0 25.01.2015...
  • Page 15: Parameters

    (that is, on the check rail) (à Fig. 9). With the adjusting knob, turn the measuring probe of the narrow support towards the crossing as far as it will go. The measurement value can now be read. © 2016 by Vogel & Plötscher GmbH & Co. KG RCAD Version 2.0 25.01.2015...
  • Page 16: Measuring Of Check Rail Gauge With Broad Measurement Base (Optional)

    4.2.4 Measuring of check rail gauge with broad measurement base (optional) Mount the broad measuring base on the corresponding fixture on the RCAD and fix it in place by the screw fitting. Then insert the broad measuring base in the switch on the crossing side. When doing so, bridge the tip of the crossing and the inside edge of the wing rail in front of the wing rail bend point (à...
  • Page 17: Back-To-Back Distance Measurement

    (à Fig. 12). Wait a few seconds until the inclination sensor has come to rest, then you can read off the measurement value. Fig. 12: © 2016 by Vogel & Plötscher GmbH & Co. KG RCAD Version 2.0 25.01.2015...
  • Page 18: Maintenance Instructions

    Check the measuring device for damage every time after transporting it. When out of the transport case, the measuring device is carried by the handle mount- ed in the centre of the unit. © 2016 by Vogel & Plötscher GmbH & Co. KG RCAD Version 2.0 25.01.2015...
  • Page 19: Battery Replacement

    Page: 17 / 28 5.3 Battery replacement The electronics of RCAD is supplied by two pieces of AA batteries inside. A screen message in the display (= Low Batt) will indicate to the user, if the batteries are weak and need to be replaced.
  • Page 20: Technical Data

    ± 0.25 Cant ± 200 ± 0.50 Dimensions and weight RCAD (length x width x height) ~ 1618 x 100 x 156 mm Weight RCAD ~ 2,5 kg Transport case (length x width x height) ~ 1750 x 200 x 190 mm Weight transport case (unloaded) ~ 7.0 kg...
  • Page 21: Rcad - 1000 Mm

    ± 0.25 Cant ± 200 ± 0.50 Dimensions and weight RCAD (length x width x height) ~ 1183 x 100 x 156 mm Weight RCAD ~ 2,3 kg Transport case (length x width x height) ~ 1350 x 200 x 190 mm Weight transport case (unloaded) ~ 6.5 kg...
  • Page 22: Rcad - 1067 Mm

    ± 0.25 Cant ± 200 ± 0.50 Dimensions and weight RCAD (length x width x height) ~ 1250 x 100 x 156 mm Weight RCAD ~ 2,3 kg Transport case (length x width x height) ~ 1350 x 200 x 190 mm Weight transport case (unloaded) ~ 6.5 kg...
  • Page 23: Rcad - 1524 Mm

    ± 0.25 Cant ± 200 ± 0.50 Dimensions and weight RCAD (length x width x height) ~ 1707 x 100 x 156 mm Weight RCAD ~ 2,6 kg Transport case (length x width x height) ~ 1840 x 200 x 190 mm Weight transport case (unloaded) ~ 7.5 kg...
  • Page 24: Rcad - 1668 Mm

    ± 0.25 Cant ± 200 ± 0.50 Dimensions and weight RCAD (length x width x height) ~ 1707 x 100 x 156 mm Weight RCAD ~ 2,6 kg Transport case (length x width x height) ~ 1840 x 200 x 190 mm Weight transport case (unloaded) ~ 7.5 kg...
  • Page 25: Ec Declaration Of Conformity

    Annex II A of the Machinery Directive (89/392/EC) The manufacturer: Vogel & Plötscher GmbH + Co. KG Geldermannstrasse 4 D-79206 Breisach Germany RCAD hereby declares that the measuring device described below: meets the health and safety requirements Directive relating to electromagnetic of the following EC Directives:...
  • Page 26: Miscellany

    If the problem occurred just once or regularly (i.e. is reproducible) § Unauthorised modification of the measuring device will result in Deutsche Bahn approval being rescinded and will void any guarantee or warranty claims. © 2016 by Vogel & Plötscher GmbH & Co. KG RCAD Version 2.0 25.01.2015...
  • Page 27: Add-Ons And Options

    9. Add-ons and options 9.1 Data storage and Bluetooth (option -BT) As an option RCAD can be supplied with flash memory incl. Bluetooth data transfer for stor- ing measurement values simply by push on a button. For details please refer to extra manual RCAD-BT.
  • Page 28: Switch Tongue Control Adapter (Option -P)

    The clearance (A) between the top of the rail and the bottom of the device can be increased as required, such as to measure cogwheel rails (à see figure below) © 2016 by Vogel & Plötscher GmbH & Co. KG RCAD Version 2.0 25.01.2015...
  • Page 29: Frog Tip Inclination (Option -H)

    With this add-on unit the height difference between the rail surface and the check rail sur- face can be measured by shifting the measuring arm vertically onto the check rail. Default measuring range: 0 – 50mm. © 2016 by Vogel & Plötscher GmbH & Co. KG RCAD Version 2.0 25.01.2015...
  • Page 30: Interchangeable Probes (Option -W)

    All interchangeable probes have a screw thread and can be replaced on the measuring de- vice by screwing in and out. 9.8 Transport case Solid and well-padded case for safe transport and storage of the RCAD device. © 2016 by Vogel & Plötscher GmbH & Co. KG RCAD Version 2.0...