Download Print this page

DeWalt DWHT77100-XJ User Manual page 11

Hide thumbs Also See for DWHT77100-XJ:

Advertisement

Specifications
Range
Measuring Accuracy*
Resolution**
Laser Class
Laser Type
Backlight Automatic Switch-off
Laser
Unit Automatic Switch-off
Continuous Measuring
Area/Volume
Battery Life (2 x AAA)
Dimension (H x D x W)
Weight (with Batteries)
Storage Temperature Range
Operating Temperature Range
*Measuring Accuracy depends on the current conditions:
• Under favorable conditions (good target surface, low background illumination, and room temperature), up to 10m. The
measurement error can increase by ± 0.1mm/m for distances over 10m
• In unfavorable conditions (poor target surface, high background illumination, operating temperatures at the Upper or lower
end of the temperature range), the measurement range may be reduced and the accuracy can increase to ± 6mm for
distances under 10m. Beyond 10m the measurement error can increase by ±0.25mm/m.
**Resolution is the finest measurement you can see. In mm, that is 1mm.
.2m to 30m
± 3mm*
1mm**
Class 2 (IEC/EN60825-1: 2014)
≤ 1.0mW @ 620-690nm
After 20s
After 120s
After 180s
Yes
Yes
Up to 3000 Measurements
120 x 48.5 x 26mm
100g
-10° C ~ +60 C
0° C ~ +40° C
E
11

Advertisement

loading

This manual is also suitable for:

Dwht77100