W11326982A
DANGER
Electrical Shock Hazard
Only authorized technicians should perform
diagnostic voltage measurements.
After performing voltage measurements,
disconnect power before servicing.
Failure to follow these instructions can result in
death or electrical shock.
WARNING
Electrical Shock Hazard
Disconnect power before servicing.
Replace all parts and panels before operating.
Failure to do so can result in death or
electrical shock.
Voltage Measurement Safety Information
When performing live voltage measurements, you
must do the following:
■ Verify the controls are in the off position so that the
appliance does not start when energized.
■ Allow enough space to perform the voltage measurements
without obstructions.
■ Keep other people a safe distance away from the appliance
to prevent potential injury.
■ Always use the proper testing equipment.
■ After voltage measurements, always disconnect power
before servicing.
FOR SERVICE TECHNICIAN'S USE ONLY / POUR LE TECHNICIEN SEULEMENT
DANGER
Risque de choc électrique
Seul un technicien autorisé est habilité à eff ectuer des
mesures de tension aux fi ns de diagnostic.
Après avoir eff ectué des mesures de tension,
déconnecter la source de courant électrique avant
toute intervention.
Le non-respect de ces instructions peut causer un
décès ou un choc électrique.
AVERTISSEMENT
Risque de choc électrique
Déconnecter la source de courant électrique avant
l'entretien.
Replacer pièces et panneaux avant de faire la remise
en marche.
Le non-respect de ces instructions peut causer un
décès ou un choc électrique.
Informations de sécurité concernant la mesure de la tension
La mesure de la tension doit être effectuée de la manière suivante:
■ Vérifier que les commandes sont à la position OFF (Arrêt)
pour que l'appareil ne démarre pas lorsqu'il est mis sous
tension.
■ Laisser suffisamment d'espace pour pouvoir faire les mesures
de tension sans qu'il y ait d'obstacle.
■ Éloigner toutes les autres personnes présentes suffisamment
loin de l'appareil pour éviter les risques de blessure.
■ Toujours utiliser l'équipement de test approprié.
■ Après les mesures de tension, toujours déconnecter la source
de courant électrique avant de procéder au service.
ACTIVATING THE SERVICE DIAGNOSTIC MODES
PELIGRO
1. Enter Diagnostics mode by pressing CANCEL>CANCEL>START within a 5-second
period.
Peligro de Choque Eléctrico
2. Press the "up" arrow keypad to scroll through the diagnostics settings.
Las mediciones de voltaje para diagnóstico deberán
NOTES:
ser realizadas solamente por técnicos autorizados.
■ Entering Diagnostics mode will cancel any active oven operation.
Después de realizar mediciones de voltaje, desconecte
■ Enter the Diagnostics mode only after the oven is cool.
el suministro de energía antes del servicio.
No seguir estas instrucciones puede ocasionar la
muerte o choque eléctrico.
ERROR CODES / CODES D'ERREUR
Code/Code
Description/Description
No display
Control not operational
ADVERTENCIA
Pas d'affichage
Module de commande non opérationnel
F1E0
Internal board failure / Défaillance de la carte de circuits interne
F1E1
Peligro de Choque Eléctrico
F1E2
A/D Error(s) / Erreur(s) A/N
Desconecte el suministro de energía antes de darle
F2E1
Shorted keypad
Clavier en courtcircuit
mantenimiento.
F3E0
Oven sensor opened / Capteur du four – circuit ouvert
Vuelva a colocar todos los componentes y paneles
Oven sensor shorted / Capteur du four – court-circuit
antes de hacerlo funcionar.
Bake/Broil range over temperature / Température excessive de cuisson au four/au gril
Clean range over temperature / Nettoyage température excessive
No seguir estas instrucciones puede ocasionar la
F5E0
Door and switches do not agree (Clean mode) (on some models)
muerte o choque eléctrico.
Non-concordance entre porte et contacteurs (mode de nettoyage)
F5E1
Door latch not operating (Clean mode) (on some models)
Loquet de porte - ne fonctionne pas (mode de nettoyage)
F6E1
Oven over temperature when heating
Dépassement température four quand four chauffe
F9E0
Miswired house / Câblage défectueux du logement
Miswired range / Câblage défectueux de la cuisinière
ACTIVATION DES MODES DE TEST DE DIAGNOSTIC DE SERVICE
1. Accéder au mode de diagnostic en appuyant sur CANCEL>CANCEL>START (annuler/
annuler/mise en marche) en moins de 5 secondes.
2. Utiliser la touche à flèche "vers le haut" pour faire défiler les réglages de diagnostic.
REMARQUES :
■ L'accès au mode de diagnostic annule toute opération du four en cours.
■ Attendre que le four ait refroidi avant d'entrer dans le mode de diagnostic.
RESISTANCES /
RÉSISTANCE
Component / Composants
Pinout / Brochage
Door switch
P3-1 to P3-2
Contacteur porte
P3-1 à P3-2
Oven temperature sensor (on some
models)
P3-4 to P3-5
Capteur thermométrique du four (sur
P3-4 à P3-5
certains modèles)
Oven light
P2-1 to WH (neutral) P1-3
Lampe du four
P2-1 à BL (neutre) P1-3
Bake element
P4-3 to P5-4
Élément de cuisson au four
P4-3 à P5-4
Convection element (on some models)
P2-4 to WH (neutral) P1-3
Élément de convection (sur certains
P2-4 à BL (neutre) P1-3
modèles)
Broil element
P5-1 to P5-4
Élément de cuisson au gril
P5-1 à P5-4
Thermo fuse
P5-1 to P5-4
Fusible thermique
P5-1 à P5-4
Door latch motor (on some models)
P3-3 to WH (neutral) P1-3
Moteur du loquet de porte (sur certains
P3-3 à BL (neutre) P1-3
modèles)
Warm Zone element (on some models)
P2-4 to WH (neutral) P1-3
Élément zone de maintien au chaud (sur
P2-4 à BL (neutre) P1-3
certains modèles)
Coil element
H1 to H2
Élément en spirale
H1 à H2
Term 2B to Term 1B / Borne 2B à 1B
Term S to Term H / Borne S à H
Element limiter switches
RR - 4 to 2 / DAR - 4 à 2
Contacteur limiteur d'élément
LR - 1 or 3 to 2A / GAR - 1 ou 3 à 2 A
LF/RF - 3 or 4 to 2A / GAV/RAV - 3 ou 4 à 2 A
© 2019
Resistance or Voltage /
Résistance ou tension
2 VDC with door open
0 VDC with door closed
2 V CC, porte ouverte
0 V CC, porte fermée
1000-1200 Ω at room
temperature
1000 - 1200 Ω à température
ambiante
0-40 Ω nominal
10-40 Ω nominal
14-17 Ω nominal
10-40 Ω nominal
240 VAC
240 VCA
500-3000 Ω
120 VAC
120 VCA
240 VAC
240 VCA
Normal = Infinite resistance
Normal = résistance infinie
Resistance of element will be
displayed
La résistance de l'élément sera
affichée

Advertisement

loading

Summary of Contents for Whirlpool WFE505W0HB

  • Page 1 W11326982A FOR SERVICE TECHNICIAN’S USE ONLY / POUR LE TECHNICIEN SEULEMENT © 2019 ACTIVATING THE SERVICE DIAGNOSTIC MODES ACTIVATION DES MODES DE TEST DE DIAGNOSTIC DE SERVICE DANGER DANGER PELIGRO 1. Enter Diagnostics mode by pressing CANCEL>CANCEL>START within a 5-second 1.
  • Page 2 W11326982A FOR SERVICE TECHNICIAN’S USE ONLY / POUR LE TECHNICIEN SEULEMENT © 2019 IMPORTANT: Electrostatic discharge may cause damage to machine control electronics. Refer to online Tech Sheet for additional information. IMPORTANT: Une décharge d’électricité statique peut faire subir des dommages aux circuits électroniques. Pour plus d’informations, se reporter à la fiche technique du produit en ligne.