[COMPRESS (16 : 9) : ON, fv: 60Hz mode ]
Measuring
Item
instrument
Signal
Adjustment
of
generator
V. HEIGHT
Remote
control unit
Screen size
Screen
size
Adjustment
Signal
of
generator
V. SLOPE
Remote
control unit
Test point
Adjustment part
13. V. ZOOM
2. VER. HEIGHT
Vertical
amplitude
1. VER. SLOPE
A
Blanking
line
B
No. 52062
Description
1. Receive a NTSC cross-hatch signal of vertical frequency 60Hz.
2. Select COMPRESS from the MENU and set COMPRESS to ON.
3. Select 3. DEF from the SERVICE MENU.
4. Set the initial setting value of 13. V. ZOOM with the MENU */Tkey.
5. Select 2. VER. HEIGHT with the MENU &/^ key.
6. Set the initial setting value of 2. VER. HEIGHT with the MENU
*/Tkey.
7. Adjust 2. VER. HEIGHT to set the vertical amplitude of the image to
295mm.
8. Receive a NTSC circle pattern signal of vertical frequency 60Hz.
9. Select 3. DEF from the SERVICE MENU.
10. Select 1. VER. SLOPE with the MENU &/^ key.
11. Set the initial setting value of 1. VER. SLOPE with the MENU
*/Tkey.
12. Adjust 1. VER. SLOPE to make "A = B" with the MENU */Tkey.
(to be continued)
AV-29LS2
AV-29LX2
AV-2968TEE
33