Before the first commissioning:
-
Check the Thermotex heating panel for visible damage and check the
accessories supplied for completeness.
-
In the event of damage or other defects to the panel, contact the supplier or
manufacturer.
Commissioning:
-
The infrared panel heating system is equipped with a connection cable with a
flat mains plug.
-
Connect the panel to the mains via a socket thermostat.
To set the room temperature, please read the instructions for use provided for
this purpose. Remove the heater from the packaging, lay it out on a flat
surface and plug the mains plug into the socket.
-
The wall heating panel can also be connected directly to the mains and be
controlled by an appropriate room thermostat.
Please contact a qualified electrician for doing this.
Safety instructions:
-
All work must be carried out in accordance with national electrical and the
relevant local regulations.
Installation and commissioning without a shockproof plug (fixed installation to
the mains) must be carried out by a licensed specialist.
-
If there are visible defects in the supply cable or the heating panel, the unit
must not be put into operation. Please inform the customer service
immediately!
-
The unit has an integrated temperature limiter of 80°C as an additional safety
feature. However, this is no substitute for an external temperature control.
-
The heating conductors described here were designed for a nominal voltage of
-
rated voltage of 230V / 50Hz. Operation at deviating nominal data is not
permitted.
-
To disconnect the heating system from the mains, an all-pole switching
disconnecting device with a contact opening width of at least 3 mm must be
provided.
-
The entire heating system is to be protected by an all-pole switching FI circuit
breaker with a maximum sensitivity of 30mA.
-
All work on the installation may only be carried out when the mains are
switched off. All safety regulations for working on the mains must be followed.
-
Connection to the mains may only be carried out by qualified electricians.