Download Print this page

Havener WHE 170 Operating Instructions

Advertisement

Quick Links

Operating instructions / Technical data
This document describes the function and installation of wall heating panels and
provides important information for safe handling during installation and initial
operation. Do not start the installation before you are sure that you have technically
understood the instructions and only carry out the work in the correct order given in
these instructions!
Intended use
The wall heating element type WHE described in this document is an electrically
operated infrared panel for indoor use. The wall heating element may only be
operated in connection with a temperature limiter (external thermostat). In order to
comply with the eco-design guidelines, a room thermostat with a built-in weekly
programme and "window open detection" is ideally recommended.
Any other use than described above is not permitted and can lead to danger or
destruction of the heating system. If you are unsure, contact the supplier or
manufacturer for further information.
Technical data:
 Dimensions: 1100 x 200 x 20 (30*) mm
 Power: 170 W ± 10%
 Protection class: I Protective earth
 Protection class: IP 20
 Power consumption: 1.3 A
 Connection: 3 m ribbon cable and plug
 Colour: white
 Weight: approx. 1.9 kg
* Unit depth including wall spacers
Where you must not use the wall heating panel:
-
Wall heating panels are not intended for outdoor use or for use in wet rooms,
such as bathrooms, showers and similar wet places.
Wall heating panel WHE 170

Advertisement

loading

Summary of Contents for Havener WHE 170

  • Page 1 Operating instructions / Technical data Wall heating panel WHE 170 This document describes the function and installation of wall heating panels and provides important information for safe handling during installation and initial operation. Do not start the installation before you are sure that you have technically...
  • Page 2 Before the first commissioning: Check the Thermotex heating panel for visible damage and check the accessories supplied for completeness. In the event of damage or other defects to the panel, contact the supplier or manufacturer. Commissioning: The infrared panel heating system is equipped with a connection cable with a flat mains plug.
  • Page 3 The side panels and rear panel of the unit can reach temperatures of up to 50°C. Therefore it is important to ensure that adjacent parts are suitable for this purpose. Children younger than 3 years must be kept away from the appliance unless they are supervised at all times.
  • Page 4 Abb.3 Abb. 1...
  • Page 5 Abb. 2 Abb. 4 Abb.5 Explanation of symbols: This symbol is found at all work safety instructions in this operating manual where there is danger to life and limb of a person. Moreover general safety and accident prevention regulations must be followed strictly. Symbol for "Do not cover Cleaning: The wall heating panel must be switched off and cooled down before cleaning.