Page 1
Adit 3500 UICK TART UIDE Part Number: 002-0250-0010 Product Release: 1.6 September 2007...
Page 2
- electronic, mechanical, magnetic, optical, chemical, manual, or otherwise - any part of this manual or software supplied with the Adit 3500 for any purpose other than the purchaser’s personal use without the express written permission of Carrier Access Corporation.
Setting up a CLI Connection Log in Key Enabled Software Features Basic Configuration Web-Based Management Restore Factory Defaults Modify Default Admin User Configure WAN Interface for Internet Connectivity Configure the Adit 3500 as a SIP Gateway UIDE Quick Start Guide...
NLESS YOU ARE A QUALIFIED SERVICE TECHNICIAN WHO USES TOOLS AND TECHNIQUES THAT CONFORM TO ACCEPTED INDUSTRY PRACTICES The ESD warning label appears on packages and storage bags that contain static-sensitive products and components. ARE EXTREMELY SUSCEPTIBLE TO ELECTROSTATIC DO NOT HANDLE Adit 3500 - Release 1.6...
Refer to the installation section of this manual for a safe and proper installation procedure. All wiring external to this equipment should follow the current provision of the National Electrical Code. Adit 3500 - Release 1.6 3000 IS DESIGNED FOR WALL AND RACK MOUNTING ONLY...
Installation Installation The following are instructions for a compliant installation of the Adit 3500. Please note the following warnings, before installing the unit. For wall and rack mount instructions, use the links listed below to the appropriate section: Wall Mounting...
3000 CLI Reference Manual, for detailed information. 10. To verify use the show version command. 11. To provision the unit. See Web-Based Management on page 23, for detailed instructions. Adit 3500 - Release 1.6 3500 IS REQUIRED TO BE PERMANENTLY GROUNDED FOR THE...
Installation Ferrite Beads The following ferrite bead is required on the Adit 3500 configurations that do not have the FXS 4 channel option. The ferrite bead will enable the Adit to be compliant with EMI standards FCC Part 15 and ICES-003 Class A.
Note: it is acceptable to mount on drywall with suitable anchor-type mounting screws. NOTE: The Adit 3000 must be mounted with the brackets on the top and bottom, as shown above. Adit 3500 - Release 1.6 Installation Back of unit...
#10-32 x 1/4” screws (two on each mounting ear). 3. Remove wall mount and screws, if attached, from Adit 3500 unit. Note: Adit 3500 and wall mounting bracket are not assembled from the factory. Rack Mounting Tray 23 in rack...
Page 11
5. Slide the assembled piece (Adit 3000 and Tray Slide) onto the installed Rack Mounting Tray. 6. Secure the Tray Slide to the Rack Mounting Tray with the attached screws on the Tray Slide. NOTE: The mounting brackets are designed to not allow units to be mounted closer than recommended. Adit 3500 - Release 1.6...
Installation There are two possible configurations to wall mount the Adit 3500 and the Battery Backup. NOTE: It is recommended that the BBU be mounted to a wooden backboard using (4) #6 screws, or to drywall using (4) #6 screws with anchors.
#1 Adit 3500 mounted on top of the Battery Backup This method will use a minimal amount of wall space. Note: This installation will require a minimum wall space of space of: 9" (H) x 14" (W) x 5" (D).
Page 14
Installation 4. Attach Adit 3500 to the assembled BBU and brackets. Each bracket attaches to the side of the Adit 3500. Note the orientation of the Adit in the graphic. 5. Attach power cords. Connect cord from BBU to the Adit 3500 (2 pin connector).
Page 15
Screw the second set of 2 screws into mounting holes on the right of the unit. Tighten all screws to the wall. 2. Insert Adit 3500 Power cord through the holder on the top of the BBU. This supports the weight of the adapter portion of the power cord.
Chassis Overview Adit 3500 Battery Backup Power Connector The following cable, is hard wired to the Adit 3500 Battery Backup and connects the Adit 3500. Pinout Wire Black Chassis Overview The following illustrations show all connectors on the Adit 3500.
Interface Connectors The following are the Adit 3500 interface connectors: Note: The following is dependant upon how the system (hardware) is configured. Systems can be ordered with/without FXS, and can have from 1-4 DS1 ports. Front of Adit 4 DS1 Ports (used for DS1 WAN and/or PRI/CAS trunks) (RJ-45C connector).
Interface Connectors 12 VAC Power Connection The Adit 3500 is powered by a 12 VAC Power Converter, which provides 12 VDC to the unit. Item Input Rate input voltage Vibration input voltage range Frequency Rated Frequency Vibration Input rated current...
Page 19
DS1/E1 Connection Ports Each DS1/E1 connection port is equipped with a standard RJ-48C (female) on the Adit 3500 unit. Note: E1 will be available in a future release. The pinouts are as follows: DS1/E1 RJ-48C The pinouts are as follows:...
The left LED shall show Link Status. Link Down Green Link Up Flashing Green Traffic on Link Yellow Collision status The right LED shall indicate Link Speed. 10 Mbit/sec, down or not connected Green 100 Mbit/sec Adit 3500 - Release 1.6...
The pinouts are as follows: Name 1 - 2 5 - 6 Reset Button The system can be reset by pressing the reset button located on the front panel. Adit 3500 - Release 1.6 Direction Description Outbound Carrier Detect Outbound...
Power-On Self Test (POST) successful. System booted. Loading Application. Flashing alternate colors. Application Self Test in Process. Yellow while booting. If this stays a steady yellow the Power-On Self Test (POST) failed. Power-On Self Test (POST) In Process. System Failure Adit 3500 - Release 1.6...
The following assumes that you have connected the PC to the LAN port of the Adit 3500. 1. Launch a web browser on your PC in the LAN to which the Adit 3500’s LAN port is connected. Note: If connection to the 3500 is to be through an Ethernet or T1 WAN, the remote admin...
NOTE: For Adit 3500 CLI commands see the Adit 3000 CLI Reference Manual. This is a separate document and can be found on the CD that is provided with the product, or on the Carrier Access customer website.
Page 25
It is recommended that you change your password from the default. Key Enabled Software Features The Adit 3500 has additional features that are not provided on the base system. These features can be purchased with the product or added later as needed. These features are enabled via a Software Key (example: G.729).
Configure the Adit 3500 as a SIP Gateway Setup Adit 3500 for access via Web-Browser The following steps will configure the Adit 3500 to allow access to the Web Browser for configuration, through the LAN (1) or WAN (2) 10/100Base-T Ethernet connections.
If the unit is not out-of-the-box, you may want to verify that the unit is set to defaults. Note: this will reset the IP address back to the default setting of 192.168.1.1. In the web-browser: Select Advanced from the Navigation bar Select Restore Defaults Select OK to restore defaults Adit 3500 - Release 1.6...
Page 29
For security purposes it is recommended that the Administrator User be changed from the default settings. Modify the Administrator User in the web-browser: Select Advanced from the Navigation bar Select Users icon Select Administrator, to open the profile. Adit 3500 - Release 1.6 Basic Configuration...
Page 30
New User to add additional users on the system. Note: For security purposes, the password should be changed from the default setting. You will be required to login again, if you have modified the User Profile that you are logged in with. Adit 3500 - Release 1.6...
Page 31
Note: Using T1 1 and the preconfigured Serial 1 makes this configuration very simple. If you use T1 2-T1 4, you will need to delete the preconfigured Serial 1 and make a New Connection (Serial 1) based on the T1 2-T1 4 that you selected. Adit 3500 - Release 1.6 Basic Configuration...
Page 32
3. Select the Settings button. 4. Set the proper Framing Type and Line Coding. 5. Select OK to apply the new settings and exit this window. 6. Select OK again to return to the Network Connections window. Adit 3500 - Release 1.6...
Page 33
Quick Start Guide Basic Configuration 7. Select (click) the Serial 1 connection. 8. Select the Settings button. Adit 3500 - Release 1.6...
Page 34
- Network Type to WAN (this is the default setting) - PPP Authentication to your required preferences 10. Select OK to apply the new settings and exit this window. 11. Select OK again to return to the Network Connections window. Adit 3500 - Release 1.6...
Page 35
Multiple T1s (Multilink) To configure Multiple T1s utilizing Multilink PPP: 1. Select Network Connections from the Navigation bar. 2. Select (click) a T1 Interface (from T1 1 - T1 4) to configure. 3. Select the Settings button. Adit 3500 - Release 1.6...
Page 36
6. Select OK again to return to the Network Connections window. 7. Repeat steps #1-6 for additional T1s required for the ML-PPP 8. Select (click) the delete icon associated with the Serial 1 connection. Select OK to confirm the deletion of this connection. Adit 3500 - Release 1.6...
Page 37
Quick Start Guide Basic Configuration 9. Select (click) New Connection to create the ML-PPP connection. 10. Select the Multilink Point-to-Point Protocol over DS0 (Multilink), and select Next. Adit 3500 - Release 1.6...
Page 38
Basic Configuration 11. Enter User Name and Password. 12. Select the T1s for this Multilink and the channel ranges. 13. Select Next. 14. A summary of the Multilink connection will be displayed. If correct, select Finish. Adit 3500 - Release 1.6...
Page 39
Quick Start Guide Basic Configuration 15. The new Multilink connection will display on the Network Connections window. 16. Select (click) the Multilink 1 connection. 17. Select the Settings button. Adit 3500 - Release 1.6...
Page 40
- Network Type to WAN (this is the default setting) - PPP Authentication to your required preferences 19. Select OK to apply the new settings and exit this window. 20. Select OK again to return to the Network Connections window. Adit 3500 - Release 1.6...
1. Select Network Connections from the Navigation bar. 2. Select (click) the delete icon associated with the Serial 1 connection. Select OK to confirm the deletion of this connection. 3. Select (click) the Ethernet 2 (WAN Ethernet) connection to configure. Adit 3500 - Release 1.6...
Page 42
6. Set Network type to WAN. 7. Set Internet Protocol option (method of IP address assignment). 8. Select OK to apply the new settings and exit this window. 9. Select OK again to return to the Network Connections window. Adit 3500 - Release 1.6...
Page 43
Quick Start Guide Basic Configuration Configure the Adit 3500 as a SIP Gateway 1. Select Voice Over IP from the Navigation bar. Adit 3500 - Release 1.6...
Page 44
- Set Proxy Type to Generic/custom (BroadSoft or Sylantro). Example: BroadSoft - Select Use SIP Proxy and enter SIP Proxy IP address - Select supported Codecs 3. Select Apply to save the new settings. 4. Select the Advanced button. Adit 3500 - Release 1.6...
Page 45
Quick Start Guide Basic Configuration 5. Modify any advanced VoIP settings as needed and select Apply. 6. Select OK to exit window. Adit 3500 - Release 1.6...
Page 46
Quick Start Guide Basic Configuration 7. If using the FXS ports, select the Phone Settings tab. 8. Select the Action icon on line #1 to edit. Adit 3500 - Release 1.6...
Page 47
10. Enter Authentication information as needed. 11. Select OK to apply and exit this window. 12. Select OK to acknowledge that with these changes, active calls will be dropped. 13. Repeat this step for each FXS Line. Adit 3500 - Release 1.6...
Page 48
Note: When a telephone port is successfully registered the Registration Status column displays "Registered" in green." 16. Select the Trunk Settings tab. 17. Select (click) on the trunk to configure. 18. Set the Trunk Signaling type to PRI or CAS. Adit 3500 - Release 1.6...
Page 49
Quick Start Guide Basic Configuration 19. Set the Signaling Type. 20. Select New Entry to assign numbers to your PRI interface(s). Adit 3500 - Release 1.6...
Page 50
SIP to the destination number to be sent to the PRI/CAS interface. 22. Select OK to save and exit this window. Note: this information will display at the bottom of the Trunk Settings window. 23. Select OK again to return to the Voice Over IP window. Adit 3500 - Release 1.6...
Page 51
Quick Start Guide Basic Configuration 24. Select the Trunk Monitoring tab to view the status of any calls on the PRI. Adit 3500 - Release 1.6...