Chengdu Ebyte Electronic Technology Co.,Ltd
Manual
16
MISO
17
MOSI
18
SCK
19
nSEL
20
GND
21
ANT
22
GND
4 Recommended circuit diagram
5 Hardware design
It is recommended to use a DC stabilized power supply. The power supply ripple factor is as small as possible and the
module needs to be reliably grounded;
Please pay attention to the correct connection of the positive and negative poles of the power supply, reverse connection
may cause permanent damage to the module;
Please check the power supply to ensure that between the recommended supply voltage, if exceeding the maximum, the
module will be permanently damaged;
Please check the stability of the power supply. Voltage can not fluctuate greatly and frequently;
When designing the power supply circuit for the module, it is often recommended to reserve more than 30% of the
margin, so the whole machine is beneficial for long-term stable operation;
The module should be as far away as possible from the power supply, transformers, high-frequency wiring and other
parts with large electromagnetic interference;
Bottom Layer High-frequency digital routing, high-frequency analog routing, and power routing must be avoided under
Copyright ©2012–2021,Chengdu Ebyte Electronic Technology Co.,Ltd.
Output
SPI master output slave input
Input
SPI master input slave output
Input
Serial Clock Input
Input
SPI Chip select for starting SPI communication
Ground wire, connected to the power reference ground
Input/Output
Antena
Ground wire, connected to the power reference ground
E30-400M30S (4463) User