At the end of each processing the tool beeps, the LED flashes and the
en
resonance frequency of the belt is shown.
6. Repeat the measurement 3 times and calculate the average of the read
values.
The values to be used for the calculation of the average must
have a difference not higher than 3 Hz.
7. Use the calculated value to derive with the special tables the tension of
the belt.
At the end of the 10 seconds the tool comes back to the status "Press to
start ...".

7.3.1 Work Zone lighting

The LED near the microphone enables to light the belt stretch and the work
zone.
Proceed as follows:
Press and release the power button.
The led lights on.
The LED will turn off automatically after about 10 s.