1. Precaution 1. Read this manual carefully before installing or servicing this equipment. 2. This equipment is designed for paint drying applications. Adjust to the correct temperature and check minimum safe distance from heat source when using. Improper use can cause paint surface damage. 3.
3. Installation The shortwave infrared curing lamp is divided into 3 parts (a base, a frame and a cassette) 1) Installation of the base: a. Open the packing of the base. b. Install the four wheels on the base and tighten up the screws. Usually, the wheels with brakes are mounted on the rear of the base.
4. Controls RUST PROOF PRIMER PRIMER PRIMARY FILLER COAT SECONDARY VARNISH FILLER 1. Voltage 2. Curing time 3. Time + 4. Time - 5/6. Lamp selector 7. Rust proof primer 8. Intermediate primer 9. Primary filler 10. Secondary filler 11. Top coat 12.
5. Operation Connection of electrical supply. Make sure that the supply cable is at least 4mm at 220V. Note: Make sure that the facility supply voltage and frequency are the same as shown on the equipment name plate. Connect to power supply of AC 220V. Switch on the equipment. The LED display will show the normal voltage as 220V.
6. Troubleshooting 1. Troubleshooting CAUSE PROBLEM SOLUTION Light tube does not work a. Light tube damaged a. Check light tube b. Lamp is not plugged in b. Check the connections Digital display is blank or a. Unplugged flat wire in a.
6. Troubleshooting 2. Lamp Tube Replacement 1. Prepare cassette for replacement 2. Remove the grille of cassette 3. Remove the plates from both ends of the cassette 4. Remove the fixed plates from both ends of the cassette 5. Loosen fixed screws and cut off connections, the lamp can be replaced 6.
Need help?
Do you have a question about the FY-2HX and is the answer not in the manual?
Questions and answers