Sear Burner Ignitor Lighting
Do not lean over barbecue while lighting.
1.Turn gas burner control valves to OFF.
2.Open lid during lighting or re-lighting.
3.Turn ON gas at LP cylinder.
4.Turn Sear Burner knob to the HIGH position, push and
hold ELECTRONIC IGNITOR button.
5.If Sear Burner does NOT light within 5 seconds, turn
knob to OFF, wait 5 minutes, then repeat lighting
procedure.
Sear Burner Match Lighting
Do not lean over barbecue while lighting.
1.Turn gas burner control valves to OFF.
2.Open lid during lighting or re-lighting.
3.Turn ON gas at LP cylinder.
4.Place lit match near burner. Immediately turn Sear
Burner knob to the HIGH position. Be sure the burner
lights and stays lit.
SPIDER AND WEBS
INSIDE BURNER
If your barbeque is getting hard to light or the flame is weak,
check and clean the venturis and burners.
Spiders or small insects are known to create "flashback"
problems by building nests and laying eggs in the barbeque's
venturi or burner obstructing the flow of gas. The backed-up
gas can ignite behind the control panel. This flashback can
damage your barbeque and cause injury. To prevent
flashbacks and ensure good performance, the burner and
venturi tube assembly should be removed and cleaned
whenever the barbeque has been idle for an extended period
of time.
Leak Testing Valves, Hose and Regulator
Leak test before first use, at least once a year, and every time
the cylinder is changed or disconnected.
1. Turn all appliance control knobs to
2. Be sure regulator is tightly connected to gas cylinder.
3. Turn on Gas. If you hear a rushing sound, turn gas off
immediately. There is a major leak at the connection.
Correct before proceeding.
4. Brush soapy solution (mixture of half soap and half water)
onto hose connections.
5. If growing bubbles appear, there is a leak. Turn off gas at
cylinder immediately and check tightness of connections. If
leak cannot be stopped do not try to repair. Call for
replacement parts.
6. Always turn off gas at cylinder after performing leak test.
IF APPLIANCE FAILS TO LIGHT
Make sure gas is turned on at cylinder.
Ÿ
Make sure there is gas in the cylinder.
Ÿ
Does the ignitor make a sparking noise?
Ÿ
If yes check for spark at burner.
If no spark check for damaged or loose wires.
If wires are OK check for cracked or broken electrode,
Ÿ
replace if needed.
If wire or electrodes are covered by cooking residue, clean
Ÿ
electrode tip with alcohol wipe if needed.
If needed replace wires.
Ÿ
If no sound check battery.
Ÿ
Make sure battery is installed correctly.
Ÿ
Check for loose wire connection at module and switch.
Ÿ
If ignitor continues to not work then use match.
Ÿ
4
.