Page 1
This document contains proprietary technical information which is the property of NETVOX Technology. It shall be maintained in strict confidence and shall not be disclosed to other parties, in whole or in part, without written permission of NETVOX Technology. The specifications are subject to change without prior notice.
The RB02I is a wireless emergency push button. It is a Class A device following the standard LoRaWAN protocol. Press the RB02I emergency button when there is an emergency, it will immediately send out the alarm to the gateway. LoRa Wireless Technology: LoRa is a wireless communication technology famous for its long-distance transmission and low power consumption.
Improved power management for longer battery life Battery Life: ⁻ Please refer to web: http://www.netvox.com.tw/electric/electric_calc.html ⁻ At this web page, users can find battery life calculation for variety models at different configurations. *Kindly note the actual battery life is determined by the actual environment and device settings.
4.Set up Instruction On/Off Open the upper cover and insert 2 AAA 1.5V batteries Power on (You may use tools to open the upper cover, such as a screwdriver) Turn on Press the function key till seeing one green indicator flash and one red indicator flash. Turn off Press and hold the function key for 5 seconds till green indicator light flashes for 20 times.
Page 6
Sleep Mode The device is turned on and Sleep period: Min Interval. in the When the reportchange exceeds setting value or the state changes: send a data report according to network Min Interval. First two mins: wake up every 15 seconds to send request. The device is turned on but After two mins: enter sleeping mode and wake up every 15 minutes to send request.
Emergency alarm: When emergency button is pressed that report “1” When emergency button is not pressed that report “0” Please refer to Netvox LoRaWAN Application Command document and Netvox LoRa Command Resolver http://www.netvox.com.cn:8888/page/index to resolve uplink data. Data report configuration and sending period are as follows: Current Change<...
Page 9
Example of ButtonPressTime configuration FPort:0x0D Description CmdID PayLoad(Var bytes) PressTime(1bytes,) 0x00_QuickPush_Less then 1 Second, OtherValue present the press time such as 0x01_1 Second push, SetButtonPressTimeReq 0x01 0x02_2 Seconds push, 0x03_3 Seconds push, 0x04_4 Seconds push, 0x05_5 Seconds push, and so on Status SetButtonPressTimeRsp 0x81...
Page 10
Example for MinTime/MaxTime logic: Example#1 based on MinTime = 1 Hour, MaxTime= 1 Hour, Reportable Change i.e. BatteryVoltageChange=0.1V MaxTime MaxTime Sleeping(MinTime) Sleeping(MinTime) Wake up and collects data Wakes up and collects data Wakes up and collects data REPORTS 3.0V REPORTS 3.0V REPORTS 3.0V Note: MaxTime=MinTime.
Attach one side of the tape to the bottom of the device "alarm" report. (RB02I) and the other side to the wall. (Please make sure the If the emergency and alarm is disarmed when it comes to surface of the wall is clear and smooth, so the device will not the regular report interval, the device will send a "normal"...
7. Important Maintenance Instruction Kindly pay attention to the following in order to achieve the best maintenance of the product: • Keep the device dry. Rain, moisture, or any liquid, might contain minerals and thus corrode electronic circuits. If the device gets wet, please dry it completely. •...
Need help?
Do you have a question about the RB02I and is the answer not in the manual?