The original of this document is in French. No translation can replace the original. Thank you for purchasing a FIXATOR product. In the following pages we give you details of instructions allowing you to safely use and maintain your equipment in good working condition. Please read these instructions prior to commissioning the equipment: no installation operation, use and maintenance should be performed until this document has been fully understood.
- male/female plug and cable power (0.50m) efficiency. - 1 manual Before its expedition by Fixator, each hoist is tested to 110% of its capacity. The LM winch cannot be used to lift or move people.
Réf : 1813000204 INSTRUCTION MANUAL Page : 4/16 Electrical winches LM500+ Version : 44/16 static test coefficient of 1.25xWLL and a dynamic Specifications test coefficient of 1.1xWLL. The LM500 winch has a working load limit of 500kg (WLL). It is displayed on the winch plate. Type 070781 CMU / WLL (kg)
If the anchoring is not provided by FIXATOR each appropriate capacity. anchor must withstand, without any deformation, up to 2.5 times the WLL of the winch, that is 1250 kg, and remain stable when subjected to this load.
Réf : 1813000204 INSTRUCTION MANUAL Page : 6/16 Electrical winches LM500+ Version : 44/16 This type of installation requires special precautions: - The bearing surface on which the unit is placed must be flat and horizontal. The resistance of the pulley and its - This surface must have a minimum Ø120mm anchorage must be calculated for a double effort of orifice for the passage of the two strands of...
Réf : 1813000204 INSTRUCTION MANUAL Page : 7/16 Electrical winches LM500+ Version : 44/16 - The surface on which the unit is placed in support must have the necessary stability and strength in regard of the safety of the operation. - The load must be in free suspension.
The power cable to the Liftho control box must be flexible cable (Class 5). Beyond 30m, it must be pour votre sécurité, n’utiliser que des câbles held in place by a suitable anchorage clamp. FIXATOR EXTENSION SECTION (mm²) at 230V Type : 0-50m...
2.2.1 Main dimensions Check the operation of the limit switches of the winch. For your safety, use only FIXATOR cables. Ensure that the cable above the hoist (taut) does not touch surfaces or angles. Ensure that the outgoing winch cable (slack) is free.
Réf : 1813000204 INSTRUCTION MANUAL Page : 10/16 Electrical winches LM500+ Version : 44/16 - Fuse protecting the command, in the electrical box. - Hooks with safety latch. The 230V single-phase motor is protected against excessive warm-ups by a probe inserted into the coil.
- To use the wire rope as a means to sling the These operations must be performed by a load competent person trained by FIXATOR or its dealers. The FIX022 manual details these annual or Residual risks control operations.
(8) pivot. After each having at least one broken wire. operation, a load test must be performed. FIXATOR or its dealers can train your staff for the maintenance of your winches. For your safety and to benefit from the full...
The groove pulley is worn or dirty Verification The brake is worn Adjust the brake The adhesion system is worn or dirty Verification Note and send the information listed on the plate Spare parts shown below before requesting parts. Use only FIXATOR original spare parts.
Réf : 1813000204 INSTRUCTION MANUAL Page : 14/16 Electrical winches LM500+ Version : 44/16 Capacitor ref 540144 Pendant control ref 462020 Motor cap ref 462021 Fuse ref 244612 Disposal Disassembly and disposal of the hoist must be in accordance with the current regulations in force. Electrical components, gear oils, greases, etc ...