superbrightleds BRI819P-B-O User Manual

superbrightleds BRI819P-B-O User Manual

Fixture-mounted motion sensor

Advertisement

Important: Read all instructions prior to installation.
Fixture-Mounted Motion Sensor

Specifications

Model
Maximum Detection Radius
Maximum Mounting Height
Operating Temperature

DIP Switch Settings

UP
UP
UP
UP
UP
UP
UP
UP
1
2
1
3
2
1
2
1
3
2
1
2
3
1
2
3
1
2
1
2
3
Setting
Switch Pair Position
Sensitivity adjusts detection area.
Time adjusts the amount of time between when motion is detected and when the light enters standby mode.
Light adjusts the daylight threshold which allows the light to stay off if motion is detected and the room is already sufficiently illuminated.
BRI819P-B-O
30 ft (9.14 m)
40 ft (12.2 m)
-40°–167° F (-40°–75° C)
UP
4
3
5
4
6
5
7
6
8
7
4
3
5
4
6
5
7
6
8
7
UP
4
5
6
7
8
4
5
6
7
UP
8
3
4
5
6
7
4
5
6
7
8
UP
UP
Sensitivity
1, 2, 3
Switch Pair Position
20%
50%
75%
100%

Safety and Notes

• Product should be installed and serviced in accordance with applicable
national, state, and local building and electrical codes.
• To reduce the risk of electric shock, ensure that the main power
source and circuit breakers are switched off before performing
any installation or wiring procedures.
UP
UP
9
8
10
9
10
9
8
10
9
10
9
10
1
2
3
9
1
10
2
1
3
2
4
3
5
8
9
10
9
10
1
UP
2
3
4
5
UP
1
2
3
4
5
Setting
Time
4, 5, 6, 7
1
2
3
4
5
1
UP
2
3
4
5
1
2
3
1
2
3
10 seconds
1
2
3
1 minute
5 minute
10 minute
30 minute
Rev Date: V1 07/15/2021
4400 Earth City Expy, St. Louis, MO 63045
User Manual
BRI819P-B-O
Check product label for specific electrical
specifications related to installation.
Improper installation will void warranty.
UP
UP
UP
UP
UP
1
UP
4
5
6
7
8
UP
4
6
5
7
6
8
7
9
8
10
1
6
7
8
9
10
1
1
6
7
8
9
10
Setting
Switch Pair Position
6
7
8
9
10
6
7
8
9
10
4
5
6
7
8
UP
4
5
6
7
8
4
5
6
7
8
866-590-3533
1
2
3
4
2
3
4
5
6
1
2
3
4
9
10
9
2
10
3
4
5
6
1
2
3
4
2
3
4
5
6
2
3
4
5
6
Light
8, 9, 10
9
10
9
10
disabled
9
10
1
2
3
4
10 lx
50 lx
300 lx
superbrightleds.com
5
6
7
5
6
7
5
6
7
7
5
6

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the BRI819P-B-O and is the answer not in the manual?

Questions and answers

Subscribe to Our Youtube Channel

Summary of Contents for superbrightleds BRI819P-B-O

  • Page 1 User Manual BRI819P-B-O Important: Read all instructions prior to installation. Fixture-Mounted Motion Sensor Safety and Notes • Product should be installed and serviced in accordance with applicable national, state, and local building and electrical codes. • To reduce the risk of electric shock, ensure that the main power source and circuit breakers are switched off before performing any installation or wiring procedures.
  • Page 2 User Manual BRI819P-B-O Important: Read all instructions prior to installation. Fixture-Mounted Motion Sensor Sensor Coverage Wiring Diagram Hot (Black) Black Power Black Load Sensor White White Neutral (White) Rev Date: V1 07/15/2021 866-590-3533 superbrightleds.com 4400 Earth City Expy, St. Louis, MO 63045...

Table of Contents