  • Page 1 USE AND INSTALLATION GUIDE...
  • Page 2: Table Of Contents

    INLET INSTALL ATION FAUCET INSTALL ATION PURE WATER INSTALL ATION CONNECT POWER COMPLETE THE INSTALL ATION REPL ACEMENT OF CARTRIDGES SYSTEM SPECIFICATIONS For installation manuals in other languages, please contact the place where you bought your ONE or visit aquaporin.com/installation.
  • Page 3: Dimensions And Weight

    DIMENSIONS AND WEIGHT Net weight: 5.7 kg Gross weight: 13.5 kg 42 cm 13.2 cm 46 cm ONE | USE AND INSTALLATION GUIDE...
  • Page 4: List Of Included Components

    Screw + nut Gasket sheet clamps 1 pair 2 pieces 1 piece Pressure Push-in PE pipe PE pipe Push-in reducer reducer 1/4″ OD 3/8″ OD fitting 1 piece 1 piece 1 piece 16 feet 6.5 feet ONE | USE AND INSTALLATION GUIDE...
  • Page 5 1 piece 1 piece 1 piece 1 piece Tools required for installation 11 mm key or Flat and Pincer Electrical drilling flexible spanner Phillips machine (6 mm and screwdriver 12 mm drill) ONE | USE AND INSTALLATION GUIDE...
  • Page 6: Safety Instructions

    Please install the device near a floor drain. Ambitious DIYers can independently conduct the installation work providing they possess the necessary skills and Reset Flush Power experience. Installation specialists are authorized to conduct installation work in line with existing regulations. ONE | USE AND INSTALLATION GUIDE...
  • Page 7 When there is no water supply or the One 220V power socket is required pipe is under repair, please disconnect in the 1-meter range of the device. the power and close the ball valve.
  • Page 8 Children must be supervised. All safety and warning information and handling instructions in the installation instructions must be complied with. Children shall not play with the appliance. ONE | USE AND INSTALLATION GUIDE...
  • Page 9: Installation Scheme

    INSTALLATION SCHEME Faucet Pure water Drain pipe Wastewater Main unit Inlet water (tap water) Water source Wastewater Inlet water Pure water ONE | USE AND INSTALLATION GUIDE...
  • Page 10: Installation

    The installation will take approximately clean your hands thoroughly as well as one hour. any tools used during the installation of your ONE. TURN Before installation, ensure that the cold water valve is turned off/closed. ONE | USE AND INSTALLATION GUIDE...
  • Page 11 1. Use a flat device, e.g. a screwdriver to push down the grey release collar. 2. You can now pull the plug upwards with your fingers. Note that there might be a release of air when removing the plugs. ONE | USE AND INSTALLATION GUIDE...
  • Page 12: Drain Installation

    1/4″ OD retaining ring 1 pair 2 pieces 1 piece Cut length to fit 2 piece Add the gasket between Drill ø 6 mm | 15/64″ the drain clamps and the drain pipe. Gasket ONE | USE AND INSTALLATION GUIDE...
  • Page 13 Cut the 1/4″ OD PE pipe to fit the installation and insert it into the wastewater connection on the machine. Push in the small retaining ring between the grey ring and the machine. Wastewater ONE | USE AND INSTALLATION GUIDE...
  • Page 14: Inlet Installation

    PE pipe ball valve reducer reducer 1/4″ OD 3/8″ OD 1 piece 1 piece 1 piece Cut length to fit Cut length to fit Small Large retaining ring retaining ring 3 pieces 2 pieces ONE | USE AND INSTALLATION GUIDE...
  • Page 15 INLET INSTALLATION Unscrew the nut from the Insert the 1/4″ OD pipe onto ball valve. the ball valve. Tighten the nut with a 11 mm key or a flexible spanner. ONE | USE AND INSTALLATION GUIDE...
  • Page 16 The arrow reducer and place a small should be pointing retaining ring between towards the ONE the blue ring and the (away from the inlet pressure reducer. water ball valve). ONE | USE AND INSTALLATION GUIDE...
  • Page 17 Cut the length of the 3/8″ OD PE pipe to fit your installation. Insert the 3/8″ mm OD PE pipe to “inlet water” on ONE. Push in a large retaining ring between the grey ring and the machine. Inlet water...
  • Page 18 INLET INSTALLATION Complete order of components for installation of inlet water Inlet water ONE | USE AND INSTALLATION GUIDE...
  • Page 19: Faucet Installation

    FAUCET INSTALLATION FAUCET KIT Faucet Spacer Upper Lower Plastic white black 1 piece 1 piece gasket gasket 1 piece 1 piece 1 piece ONE | USE AND INSTALLATION GUIDE...
  • Page 20 FAUCET INSTALLATION Drill ø 12 mm / 15/32″ Drill a hole adjacent to your regular faucet. Assemble Remove the rubber and tighten cover from the faucet. with your hands (no use of tools). Rubber cover ONE | USE AND INSTALLATION GUIDE...
  • Page 21: Pure Water Installation

    PURE WATER INSTALLATION Push-in Small PE pipe fitting retaining ring 1/4″ OD 1 piece 3 pieces Cut length to fit ONE | USE AND INSTALLATION GUIDE...
  • Page 22 Cut the length of the 1/4″ OD PE pipe to fit your installation and insert it into the pure water connection on the machine. Push in a small Pure water retaining ring between the grey ring and the machine. ONE | USE AND INSTALLATION GUIDE...
  • Page 23: Connect Power

    ONE into the power adaptor and tighten. If desired, the power adaptor can be mounted to a wall or cabinet with two screws. Screws for this step are not included. ONE | USE AND INSTALLATION GUIDE...
  • Page 24: Complete The Installation

    PE pipe. Remember to flush before consuming You will be left with one spare part the water! which is one large retaining ring. Discard or keep this for later use if you are to re-locate your ONE.
  • Page 25: Replacement Of Cartridges

    REPLACEMENT OF CARTRIDGES There are two cartridges inside ONE; The cartridge replacement intervals a PCB filter which is a 2-in-1 filter are indicative only as the condition is and works as both a pre- and post- affected by the quality of the source treatment, as well as an Aquaporin water which may vary.
  • Page 26 REPLACEMENT OF CARTRIDGES 1/10 2/10 Close the ball valve. Unplug the power supply. UNPLUG TURN 3/10 Find the cartridge that needs to be replaced. DWRO™ membrane filter ONE | USE AND INSTALLATION GUIDE...
  • Page 27 CLOSE RELESE 6/10 Take out the cartridge that you are replacing. Insert the new cartridge and tighten to the mark position. Screw the rotary cover back in and close the handle. ONE | USE AND INSTALLATION GUIDE...
  • Page 28 This is totally normal as some of the activated carbon is washed out. After replacing the DWRO™ Reset Flush Power membrane, open your faucet and let the water flow for 30 minutes. ONE | USE AND INSTALLATION GUIDE...
  • Page 29: System Specifications

    SYSTEM SPECIFICATIONS ONE – powered by Aquaporin Inside is a water purifier ® dedicated to make safe and great tasting drinking water. T R E AT M E N T S T E P S Pre- and post- filtration PCB filter (PAC and PP)
  • Page 30 Aquaporin A/S Nymøllevej 78 2800 Kongens Lyngby Denmark VAT No.: DK28315694 Tel: +45 82 30 30 82 sales@aquaporin.com aquaporin.com ONE-Installation-guide-EN | Revised: 15 MAR 2021...