When you install the connecting cables make sure
not to excessively shorten the cable leading to the
connector in the lower part of the sensor casing so
that you can later maintain or dismounting the sensor.
Put further a cable loop as sensor protection against
water under the sensor.
Tip: Install the sensors on ground to the traverse and
align you the wind vane parallel to the traverse. You
go only then upward, in order to accordingly align the
sensors with traverse under assistance of a partner
on ground.
3
Setting up the North direction
of the wind direction sensor
For wind direction measurements the North mark on the sen-
sor must be aligned with the geographical north direction.
You have to turn the marking exactly over the marking at the
sensor shaft. When you have aligned the marks, you may fix
the wind vane with e.g. a piece of adhesive tape. When you
have fixed the wind vane this way you can locate the refer-
ence point by aiming at it over the axis. Now you must turn the
sensor casing on the mounting tube until the tip of the wind
vane points to the reference point in the north.
To set up the sensor's north orientation select a landmark
which is as far as possible up north with regard to the final
position of the wind direction sensor.
The reference point can be selected using a topographical
map (1:25000). The exact position of the reference point is
determined using an amplitude compass that can be adjusted
horizontally on a stand.
Please make sure there is no magnetic deviation
of the compass.
When the North direction is set up for the wind direction sen-
sor, you can mounting it like under point "Principle of installa-
tion". Remove any adhesive tape.
If you cannot select a northern reference point owing to local
conditions, you can proceed analogously using a reference
point in the south. In this case, however, you have to make
sure the north mark on the sensor does not point to the refer-
ence point but in the opposite direction.
4

Electrical connection

Wind sensors EFFICIENT Modbus are connected to a data
measuring system via the open cable end. The sensors have
a cable-plug connection to the cable.
The connecting cable is suitably led along the mast between
the data evaluation device (indicating instrument or data ac-
quisition system) and the sensor. The cable must be fastened
using appropriate cable ties (their length depends on the mast
diameter).
Lead the cable in a wide curve from the mast to the
bottom of the casing so that you can later easily
dismount the cable.
4
(14579) EFFICIENT Modbus
Please note that the cable on the data processing side is pro-
tected against moisture, e.g. by using suitable cable glands.
If the mast is prepared accordingly, the connection cable can
also be laid completely in the pipe sections of a mast.
To reduce the risk of inductive interference the
sensor must be properly grounded (screening
on both sides).
5

Heating

The sensor has an electronically controlled 18 watt heating
in the sensor head. The heating is powered along with the
electronics of the sensor.
Heating
Heizung
H
6

Maintenance

The sensor design permits long periods of maintenance-free
operation. We therefore recommend a regular visual verifica-
tion of the north setup of the wind direction sensor as well as
a sensor calibration of both sensor types in the distance of
2 years.
Manual
Under most climatological condi-
tions the heating prevents blocking
of the moving sensor parts (see
illustration). The cup rotor or the
wind vane are not heated. In case
of icing or formation of ice at the
moving sensor element the func-
tion is restricted for the period of
icing.