Troubleshooting; Symptoms That Seemingly Appear To Be Failures - Hitachi ULTRAVISION DIGITAL CMP4120HDUS User Manual

Color plasma display monitor
Hide thumbs Also See for ULTRAVISION DIGITAL CMP4120HDUS:
Table of Contents

Advertisement

TROUBLESHOOTING

Symptoms That Seemingly Appear to be Failures

Make the checks suggested below depending on the symptoms observed. If the
symptoms remain uncorrected, contact your dealer.
WARNING
Symptom
• No picture with the power-
indicating lamp off.
• The message "POWER
SAVE" is displayed.
• No picture with the power
indicating lamp flickering in
green.
• The message "OUT OF
FREQUENCY" is displayed.
• The power indicating lamp is
normally lit but no picture .
• The display image appears
flowing slantwise.
• Text displayed across the
screen appears vertically
streaked, with the characters
in vertical columns blurred.
• Text displayed across the
screen appears blurred.
• A fine pattern flickers when
displayed on the screen.
• The remote controller does not work.
• Customer servicing can be hazardous.
• Check the way the power cable is connected.
• Press the power switch.
No sync signal is detected.
• Check the way the signal cable is connected.
• Make sure that the switch of the computer,
POWER SAVE
imaging equipment , etc., is turned on.
• Make sure the computer is not in the power-save
mode.
• Check to see if the input selection matches the
connection terminal.
An input signal is not received normally.
• Check to see if the input signal matches the
monitor specifications.
OUT OF FRQUENCY
• Check the way the signal cable is connected.
• Check the contrast and brightness settings
(adjust them for higher contrast and brightness).
• Check the way the signal cable is connected.
• Adjust the dot clock frequency and phase.
(Adjust the dot clock frequency first, the dot clock
phase next.)
(RGB input)
• Adjust the dot clock phase for the clearest
viewing.
(RGB input)
• Check to see if the batteries are loaded in the
remote controller in opposite direction.
• Check to see if the batteries in the remote
controller are OK.
Point to check
See
page
6
7
9
6
7
9
21
22
6
7
21
27
29
6
7
11
13
16
25
16
26
8
23

Advertisement

Table of Contents
loading

Table of Contents