The table below shows which Profidrive specific parameters that are supported by the SJ-PB(T).
PNU -
Parameter Number
915
Assignment of PZD write word
3-10
916
Assignment of PZD read word
3-10
918
Profibus-DP slave address
927
Parameter edit rights
928
Control rights (process data).
947
Indexed Fault memory
963
PROFIBUS-DP baud rate
964
Device identification
965
Profile version
967
Control Word
968
Status Word
971
Transfer
into
non-volatile
memory
Table 5-1 Profidrive parameters
Description
Refer to chapter 5.3.3 and 5.4.3 for how to assign PZD
words. Use the parameter cross-reference list in
chapter 5.
Please note: Parameters will be lost when turning
power off unless parameter 971 has been written with
"0->1".
Refer to chapter 5.3.3 and 5.4.2 for how to assign PZD
words. Use the parameter cross-reference list in
chapter 5.
Please note: Parameters will be lost when turning
power off unless parameter 971 has been written with
"0->1".
Returns address switch setting.
1 – PKW interface enabled. Parameters can be
read/written.
0 – PKW interface disabled, only parameter 927 can
be read/written.
1 – Option board will send control word, reference and
will update PZD3-10.
0 – PZD not enabled.
Fault. Codes as described in table 5-2 below.
Sub-index 1 = Not acknowledged fault.
Sub-index 9 = Latest acknowledged fault.
nd
Sub-index 17 = 2
latest acknowledged fault.
rd
Sub-index 25 = 3
latest acknowledged fault.
Sub-index 33 = 4
th
latest acknowledged fault.
Sub-index 41 = 5
th
latest acknowledged fault.
th
Sub-index 49 = 6
latest acknowledged fault.
the baudrate of the Profibus-DP network
0: 12 Mbit/s 1: 6 Mbit/s 2: 3 Mbit/s 3: 1.5 Mbit/s
4: 500 kbit/s 5: 187.5 kbit/s 6: 93.75 kbit/s
7: 45.45 kbit/s 8: 19.2 kbit/s 9: 9.6 kbit/s
Bit 15 represents the type of inverter, 0 – SJxxx, 1 –
LxxxP. Rest of the word represents the model number.
SJ300 - 0x012C
L300P - 0x812C
Returns the Profidrive profile version used in the SJ-PB
implementation
Shows the latest received control word in hex format
Refer to chapter 5.3.1 for detailed information about
the control word.
Shows the latest status word in hex format
Refer to chapter 5.3.1 for detailed information about
the status word.
Please note that it will take approximately 10s for this
process to finish (inverter must be stopped).
0 – No function.
1 – Will save inverter parameters to non-volatile
memory and the Profile specific parameters to FLASH.
19
CHAPTER5 OPERATING
Range
Parameter range:
1 – 418.
Sub-index range:
1 – 8.
Parameter range:
1 – 418.
Sub-index range:
1 – 8.
1-99
0, 1
0, 1
-
0-9
012Ch, 812Ch
2
Bit 0-15
Bit 0-15
0, 1
R/W
R/W
R
R/W
R/W
R
R
R
R
R
R
W

Advertisement

Table of Contents
loading

This manual is also suitable for:

Sj-pb

Table of Contents