• Always switch off the power before installation or maintenance and make sure that power is disconnected. Read the manual carefully before installing the product. Improper installation can be fatal. The manufacturer or distributor is not responsible for the consequences of incorrect installation or use. www.nerival.fi...
Technical information Model NEO-80 Door max. weight 100kg, recommended 80kg Door max. width 1200mm, recommended 1000mm Weight 6,5kg Service life More than 1.000.000 operations Installation method Surface mounting 12VDC Voltage output for locking With included relay card 12V AC/DC - 30V AC/DC...
Outward opening door: Installation with push arm (door operator inside) Loosen the screws to set the push arm at a 90-degree angle to the door. Adjust the limit block in the correct position when the door is open. www.nerival.fi...
Sensor signal Sensor signal input Sensor signal Sensor signal input Voltage output +12VDC, max 200mA Voltage output -0VDC OpeningDoor anti-collision Opening door safety sensor input ClosingDoor anti-collision Closing door safety sensor input Access control signal Access control signal input www.nerival.fi...
Page 10
Double door synchronization/COM: Synchronization of two door operators. Both door operators operate simultaneously. When the input is active, the display shows * Use the supplied relay card if voltage used for locking is other than 12VDC. www.nerival.fi...
If the device cannot detect the correct stop position, the error message "E08" is displayed. • If the door closes in the wrong direction, see setting no. 9. • To skip the self-learning process, press the ▲ button to enter the setting mode. www.nerival.fi...
Opening direction 1: right see Adding a remote control Adding a remote 0-40 Additional controller e.g. control Nerival #33340 RCT-1224 Opening door anti- The lower the delay, the faster the 0-10 collision delay door stops in a collision Closing door anti-...
1: pois päältä Closing door anti- 1: N.O collision input method 2: N.C Mode when the door 0: the door closes is opened by force 1: the door opens 0: empty Restore factory 1: resets all settings to factory settings defaults www.nerival.fi...
4. The remote control has been added successfully. Repeat the above steps to add more remote controls. Additional controller e.g. Nerival #33340 RCT-1224 (Note Additional controller only works in remote control mode 1, see setting no. 17) Maximum quantity 40 pcs Deleting remote controls 1.
Voltage is too high Check voltage Voltage is too low Check voltage No door was detected Check the attachment of the pull and push arm Check the door, remove obstacles in front of the The door does not close door www.nerival.fi...