• Always switch off the power before installation or maintenance and make sure that power is disconnected. Read the manual carefully before installing the product. Improper installation can be fatal. The manufacturer or distributor is not responsible for the consequences of incorrect installation or use. www.nerival.fi...
580mm x 80mm x 90mm Approvals EU Directive Test Standard(s) EU Directive Test Standard(s) EN 62321-1:2013 EN IEC 61000-6-1:2019 EN 62321-2:2014 2014/30/EU EN 61000-6-3:2007/A1:2011 EN 62321-3-1:2014 (EMC) /AC:2012 EN 62321-4:2014+A1:2017 2011/65/EU EN 62321-5:2014 (RoHs) EN 62321-6:2015 EN 62321-7-1:2015 EN 62321-7-2:2017 EN 62321-8:2017 www.nerival.fi...
Outward opening door: Installation with push arm (door operator inside) Loosen the screws to set the push arm at a 90-degree angle to the door. www.nerival.fi...
Electric lock output +12VDC* Electric lock output -12VDC* Voltage output -12VDC Voltage output +12VDC, max 500mA Voltage signal 12VDC Door open signal Door close signal Closing door safety sensor input Opening door safety sensor input Synchronization of two door operators www.nerival.fi...
Page 10
P4/GND: Safety sensor for opening door. When the sensor detects, the door stops. P5/GND: Synchronization of two door operators. Both door operators operate simultaneously. * Use the included relay card if voltage used for locking is other than 12VDC. www.nerival.fi...
If the device cannot detect the correct stop position, the error message "E08" is displayed. • If the door closes in the wrong direction, see setting no. 9. • To skip the self-learning process, press the ▲ button to enter the setting mode. www.nerival.fi...
The lower the delay, the faster the 0-30 collision delay door stops in a collision Closing speed after 0-20 Closing speed after reset reset Standard voltage signal input *P1+ signal mode Lock signal ends P1 Automatic switch *P1, P2 Port function P2 Forced off www.nerival.fi...
Asetuksen Toiminto Asetusalue Lisätiedot numero 0: normal Encoder direction 1: reverse 0: power on: locked Type of electric lock 1: power off: locked 0: off Windproof mode 1: windproof 0: Lock release Protected mode 1: Access control 2: Autoreset www.nerival.fi...
[33340] RCT-1224 Wireless transmitter, 433Mhz (only automatic mode/open function) Maximum quantity 40 pcs Deleting remote controls 1. Got to setting no. 22 2. Set value to 10 3. Press the Save button 4. All the remote controls have been successfully deleted. www.nerival.fi...
Too high AC voltage Check voltage Too low AC voltage Check voltage Check the attachment of the pull and push No door was detected Check the door, remove obstacles in front of The door does not close the door www.nerival.fi...