1. IMPORTANT SAFETY NOTES SITUATIONS AND TO MAKE CORRECT USE OF THIS PRODUCT. Signs and symbols This is the safety alert symbol. It Whenever used, the following signs identify safety and alerts you to potential personal property damage messages and designate a level of injury hazards.
Page 3
– people with electrical implants, such as a cardiac pacemaker CAUTION CAUTION indicates a hazardous people with renal diseases – situation which, if not avoided, – women who are pregnant may result in minor or moderate patient motion during measurement –...
Page 4
• Only a physician or a trained health care profession- – the release of an arterial or venous thrombus, al who is familiar with your medical history is able which can cause a life threatening situation. • Please contact your physician about the specific to accurately interpret your blood pressure meas- urements.
Page 5
• Prior to use, you have to ensure that the blood pres- tal disorders or the like. Consult your physician for sure monitor is free of damage. If in doubt, do not alternative methods of measuring a child’s blood use the unit and contact customer service at 1-800- pressure.
Page 6
• People with disabilities, activity limitations, or who • Do not measure your blood pressure while oper- are physically frail, should be assisted by another ating a vehicle or in any situation which requires person when using this unit. your full attention. •...
Page 7
• Remove any kind of arm jewelry or the like before weak pulses. In rare cases a mark may persist for taking a measurement. This could cause bruises. a couple of days. Please contact your physician • Do not place the cuff over heavy clothing (e.g. a about these specific risks of cuff pressure in your jacket or sweater sleeve) as the blood pressure specific case.
Page 8
• Do not wash the unit in a washing machine, dish ress, except for stopping the measurement. Doing so may cause incorrect readings. washer or tumble dryer. • Observe the local regulations for material disposal. NOTICE: Dispose of the device, components and optional •...
• To conserve the batteries, the monitor switches • Clean your device and cuff carefully only with a off automatically if no buttons are pressed for one slightly moistened soft cloth and dry it immediately minute. with a soft dry cloth. Do not press. •...
Page 10
• Do not use the blood pressure monitor on newborns, time depending on your individual physiological characteristics. Because of normal physiologic chan- pregnant women or patients with pre-eclampsia. ges and the many external factors influencing blood Consult your doctor before using the blood pres- pressure, it is unusual to obtain identical blood pres- sure monitor during pregnancy.
Page 11
• Remove discharged batteries from the product and Battery Handling Safety Precautions dispose/recycle in compliance with all applicable • Use only the size and type of batteries specified. laws. • Be sure to follow the correct polarity when installing • Keep batteries away from children and pets. Bat- the batteries.
Page 12
SAFETY INSTRUCTIONS SAVE THESE INSTRUCTIONS FOR • Keep the charger in a dry place (indoor use only). FUTURE REFERENCE In order to avoid the risk of fire and/or electric If the instruction manual is damaged or if you no shock, the charger must be protected against longer have the instruction manual in your posses- high humidity and water.
2. Indication for use Direct current The upper arm blood pressure monitor is used to carry Storage Permissible storage out non-invasive measurement and monitoring of the temperature and humidity arterial blood pressure values in adults. This allows you to quickly and easily measure your blood pressure, save Operating Permissible operating the measured values and display the development and...
5. Device description Icons in the display: mmHg mmHg /min Bluetooth ® 1. Time and Date 2. Systolic Pressure 3. Diastolic Pressure 1. Arm Cuff 4. Pulse Rate 2. Air Tube 5. Irregular Heartbeat Indicator 3. Air Tube Connector 6. Battery Level Indicator 4.
System requirements for the ‘beurer Operation with the mains part You can also operate this device with a mains part. HealthCoach‘ app When doing so, there must not be any batteries in ® Bluetooth 4.0, iOS from version 8.0, Android from the battery compartment.
Page 16
Setting the hour format, date, time and 6. The hour flashes on the LCD Display. Set the hour with the +/- Buttons and press the SET Button to ® Bluetooth settings: confirm. If date and time are not set, stored measurements will 7.
7. Measuring Blood Pressure The cuff must be placed on the upper arm so that the The blood pressure monitor needs to be at room bottom edge is positioned temperature when measuring. Measurements can 0.8 - 1.2 in (2-3 cm) above be performed on either arm.
• To perform a measurement, sit comfortably with If the values between the two arms are significantly different, please consult your doctor to determine your arms and back supported. Do not cross your which arm should be used for the measurement. legs and place your feet flat on the floor.
Page 19
2. As a measurement concludes, air pressure in ® Bluetooth data transfer the Cuff will release. The pulse symbol will ® If the Bluetooth function is activated on the unit, display, along with systolic and diastolic measurement data is transferred to your paired mo- pressure.
8. Evaluating Results treatment based solely on the test results may be dan- gerous. It is vital to follow your doctor‘s instructions Irregular Heartbeat: Blood Pressure Classifications This device can detect irregular heartbeat patterns Measurements can be classified and assessed by the during measurement and will indicate them by table below.
9. Displaying and Deleting Meas- Blood pres- Systole Diastole sure value Action urements (in mmHg) (in mmHg) category regular mon- User Memory: 130 – 139 85 – 89 High normal itoring by doc- Every successful measurement is stored along with its date and time.
Copying Stored Measurements using • Press the M button a third time. ’ ’ ® Bluetooth flashes on the display. The average val- ue of the evening measurements for the 1. Download and install the HealthCoach’ app last seven days is displayed (evening: from your device’s app store.
12. Specifications • Never immerse the device in water or other liquids. • When storing the device, make sure no heavy ob- Model MD3600 /MD3610 (Mains Part) jects are placed on top of it. Remove the batteries. Measurement Oscillometric, non-invasive Ensure the Air Tube does not have any sharp kinks.
Page 24
Measurement Max. permissible standard Battery Life Approx. 200 measurements inaccuracy deviation according to clinical (depending on levels of blood testing: Systolic 8 mmHg / pressure and pump pressure/ ® Diastolic 8 mmHg Bluetooth transfer) Memory 4 x 30 memory spaces Accessories Instructions for use, 4 x 1.5V AA batteries, storage pouch...
13. Mains part with regard to electromagnetic compatibility. Please note that portable and mobile HF communication Model no. LXCP12-006060BEH systems may interfere with this unit. More details can 100 – 240V, 50 – 60 Hz Input be requested from the stated Customer Services ad- Output 6V DC, 600 mA dress or found at the end of the instructions for use.
– Increase the separation between the equipment and 14. FCC Statement receiver. Changes or modifications to the product not express- – Connect the equipment into an outlet on a circuit dif- ly approved by the party responsible for compliance ferent from that to which the receiver is connected. could void the user’s authority to operate the equip- –...
Page 27
IC Regulations/Réglementations de l’IC : This device contains licence-exempt transmitter(s)/receiver(s) that comply with Innovation, Science and Economic Development Canada’s licence-exempt RSS(s). Operation is subject to the following two conditions: 1 This device may not cause interference. This device must accept any interference, including interference that may cause undesired operation of the device.
Page 28
Appendix I The Sphygmomanometer (MD3600/ MD3610) is intended for use in the electromagnetic environment specified below. The customer or the user of the Sphygmomanometer (MD3600/ MD3610) should assure that it is used in such an environment. Conducted and Compliance Electromagnetic environment - guidance...
Page 29
The Sphygmomanometer (MD3600/ MD3610) is intended for use in the electromagnetic environment specified below. The customer of the user of Sphygmomanometer (MD3600/ MD3610) should assure that it is used in such an environment. Floors should be wood, concrete or Electrostatic discharge ceramic tile.
Page 30
Appendix II The Sphygmomanometer (MD3600/ MD3610) is intended for use in the electromagnetic environment specified below. The customer of the user of Sphygmomanometer (MD3600/ MD3610) should assure that it is used in such an environment. IEC 60601 Immunity test Compliance level...
Page 31
NOTE These guidelines may not apply in all situations. Electromagnetic propagation is affected by absorption and reflection from structures, objects and people. r.m.s., before modulation is applied. The ISM (industrial, scientific and medical) bands between 0,15 MHz and 80 MHz are 6,765 MHz to 6,795 MHz;...
Page 32
Appendix III Recommended separation distances between portable and mobile RF communications equipment and the Sphygmomanometer (MD3600/ MD3610) 3600/ 3610 The Sphygmomanometer (MD ) is intended for use in an electromagnetic environment in which radiated RF 3600/ MD3610 disturbances are controlled. The customer or the user of the Sphygmomanometer (MD...
Page 33
Symbol for the marking of electrical and electronics devices according to Directive 2002/96/EC. The device, accessories and the packaging have to be disposed of waste correctly at the end of the usage. Please follow Local Ordinances or Regulations for disposal. Grandway Technology (Shenzhen) Limited No. 5, the Second Industrial Zone, Zhukeng Community, Longtian Street, Pingshan District, Shenzhen, 518118 The People’s Republic of China...
Need help?
Do you have a question about the MD3600 and is the answer not in the manual?
Questions and answers