Haier HSU-09HS03/R2DB Service Manual page 25

Domestic air conditioner
Hide thumbs Also See for HSU-09HS03/R2DB:
Table of Contents

Advertisement

Cooling
deviation to zero
Moisture removing
deviation to level G
Heating
deviation to level F
There will be no DASH operation under trial operation, emergency operation and
silent operation modes.
2.4.5 Temperature adjusting of different levels. (DASH operation conditions under
different modes)
cooling 制冷 / moisture removing 除湿 /heating 制热 /level 区 段/ cooling 制冷 /
moisture removing 除湿 /heating 制热 /Value E
mode 3 分钟待机 /compressor resta`1rt 压缩机再启动
2.4.6 Frequencies for different levels
Within different levels, the indicated frequencies are(the frequency the indoor unit
transmits to the outdoor unit) as follows ;
Under the cooling & moisture-removing mode, level A and B have the same
frequency.
Under the silent mode, levels A-E have the same frequency with level F
Indicated frequency
Heating
FQHOT [0—7]
Silent
FQSHOT [0—2]
heating
Moisture
FQDRY [0—7]
removing
Cooling
FQCOOL [0—7]
Silent
FQSCOOL [0—2]
cooling
Domestic Air Conditioner
Frequency
range
25
Model:
E 值 /<120 seconds/ 3-minute idle
Temperature
change level
A—H
F—H
B—H
B—H
F—H
HSU-12HS03/R2(DB)
HSU-09HS03/R2(DB)