Index PACK CONTENTS............2 SYSTEM MANAGEMENT FROM GRAPHIC KEYPAD INSTALLATION.............. 2 INFO TASK BAR..........11 COMPLIANCE............... 2 DATE AND TIME SETTING......... 12 TECHNICAL VOCABULARY..........2 KEYPAD SETTINGS........... 12 MANUFACTURER............VOICE MESSAGE..........13 SPECIFICATIONS............3 ARM/DISARM CONTROL PANEL......14 WARRANTY..............3 ACTIVATION OF PROGRAMMED OUTPUTS..
• The backup battery used must comply with the IEC 60896-21/2 and have a V0 fireproof casing COMPLIANCE AMC Elettronica declares that its alarm control panels comply with the requirements and provisions established by directive 1999/5/CE and with the standards EN50131-1, EN50131-3, EN50131-6, EN50136-1, EN50136-2 (PSTN line , GSM, GPRS, LAN modules ATS3/SP3).
• wear of the product • lightning, floods, fire AMC Elettronica reserves the right to repair or replace the defective product within the established limit of 24 months. Any use other than that indicated in this manual will invalidate the warranty.
SYSTEM MANAGEMENT FROM DISPLAY KEYPAD To use the user menu, enter the personal code and press the ESC key within 3 seconds. Using the arrows 1 and 2 it will be possible to move within the menu. ENTER key: X key: ARM/DISARM AREAS/GROUPS With the system disarmed enter the personal code (default 111111).
Bypass with zones not ready: during the arming procedure, the keypad shows the message “zones not ready”, and proposes selecting 1 = include, 2 = inhibit, 3 = verify. When 3 is selected, the bypass menu is highlighted (see figure). [01] ZONE 01 Pressing X repeatedly allows selecting PT - - - - - - - - - - - - - - - - -...
ENABLING INSTALLER ACCESS Access to the programming menu by the installer must be enabled via the personal user code. Entering the user menu, under the item ENABLE INSTALLER ACCESS it is possible to select 1 to enable or 0 to disable the installer to access the programming menu.
ACTIVATION OF PROGRAMMED OUTPUTS In this menu it is possible to ACTIVATE / DEACTIVATE previously duly programmed OUTPUTS. Enter the menu, position on the desired output (right/ ACTIVATE left arrows) and use the UP/DOWN arrows to activate/deactivate. OUTPUTS The figure displays what is shown in the Menu. The outputs that can be managed are only those with 0 = deactivated and 1 = activated.
The control panel is equipped with a test tool to be able to verify the correct operation of the system, however AMC recommends always using a professional installer to perform the test. The tests that can be performed are on: •...
SYSTEM MANAGEMENT VIA SMS ARM/DISARM THE CONTROL PANEL VIA SMS The control panel can also be armed or disarmed by sending an SMS message as follows: UPWD:( ) ARM=T TOTAL ARMING user code UPWD:( ) ARM=1 PARTIAL ARMING 1 user code UPWD:( ) ARM=12357 ARMING OF PARTIALS 1 - 2 - 3 - 5 - 7 user code...
SYSTEM MANAGEMENT VIA VOICE GUIDANCE Only for X-XV Series The control panel is able to provide information and guide the user through a voice-guided menu. To access the voice menu it is necessary to contact the control panel by telephone: 1- Enter the telephone number of the control panel (the control panel will answer after a number of rings set by the installer during programming) and follow the voice instructions.
SYSTEM MANAGEMENT FROM GRAPHIC KEYPAD UNIKA is a touchscreen keypad with 5-inch screen and a thin ABS cover. Equipped with an intuitive graphic interface it is easy to use. With just a few taps on the coloured icons it is possible to manage all the system functions.
DATE AND TIME SETTING Tapping the CALENDAR icon on the home page, it is possible to set the date and time of the control panel. KEYPAD SETTINGS By tapping the KEYPAD SETTINGS icon on the home page and entering your code, the following screen will appear from which it is possible to set certain keypad parameters.
If the internal RFID has been previously enabled by the installer it is possible to program the proximity key. By tapping the TAG key, an animation will appear prompting the action of bringing the proximity key close to the reading area. Successful programming will be signalled by an acoustic signal and a green icon. Tapping on the bin icon, all the proximity keys linked to the user code with which the user is logged in will be deleted.
ARM/DISARM CONTROL PANEL During the programming phase, it is possible to activate the system without requiring any code (quick arm). This possibility must be set by the installer. Tapping the ARM/DISARM icon on the home screen prompts the entering of your code. Subsequently, the keypad will show 4 activation GROUPS (G1, G2, G3, G4) and the AREAS (A1, A2, A3, A4, A5, A6,...
ACTIVATION OF PROGRAMMED OUTPUTS Tapping on the COMMAND ACTIVATION icon, the list of activated (yellow) and deactivated (white) commands will appear on the home page. Tapping the relative key activates/deactivates the command. It is possible, during the system programming phase, to create commands under a specific code. If there are commands of this type, the window will show on the left the icon of a keypad through which it will be possible to enter the code to view all the associated commands.
READ EVENTS MEMORY Tapping the READ EVENTS MEMORY icon on the home page prompts the typing in of your code. The list of all the events of the control panel will appear. Holding down the READ EVENTS MEMORY icon on the home page for 2 seconds prompts the typing in of your code and icons will appear representing event type groups.
SYSTEM MANAGEMENT VIA APP AMCPlus AMCPlus+ VIDEO VERIFICATION REGISTERING THE APP 1.1 Download the App and proceed with registration 1.2 Fill in all the required fields. Set a password by tapping the appropriate “Sign Up” key. and press the “Sign Up” key. 1.3 A code will be sent via e-mail.
PAIRING THE CONTROL PANEL 2.1 Click on the key “+” 2.2 Fill in all the The required fields 2 - 3 - 4 in this to add the control panels. required fields: section must correspond to those entered during the programming phase by the installer.
Page 20
3.2 Use the appropriate 3.3 Clicking on the arrow accesses the sections where it is possible to key to arm the system in arm/disarm the GROUPS and the AREAS, to exclude/include the ZONES and activate/deactivate the OUTPUTS. total way. 3.4 Use the appropriate key to arm the individual Group.
3.7 Clicking on the individual GROUPS, AREAS, ZONES, OUTPUTS accesses a screen on which to assign an image (allow access to the camera). Clicking on the appropriate button it is possible to view the icons of the GROUPS, AREAS, ZONES, OUTPUTS on the map and act directly from this screen.
OTHER FUNCTIONS SYSTEM STATUS menu NOTIFICATIONS menu Through this menu it is possible Through this menu it is possible to receive the following default notifications: alarms and anomalies to check the status of the control panel: battery level, power supply, The installer, during the programming phase, can enable the phone line etc.
Page 24
AMC Elettronica Via Pascoli, 359 - 22040 Alzate Brianza (CO) Italy info@amcelettronica.com - www.amcelettronica.com Due to the continuous improvement of its products, AMC reserves the right to modify or replace technical specifications and information contained in this manual without prior notice.