Augustine Surgical HotDog U101 Instructions For Use Manual

Patient warming mattresses

Advertisement

Models U1XX, U2XX and U3XX
Manufactured by:
Augustine Temperature Management
7656 West 78
th
Street
Bloomington, MN 55439 USA
TEL: 952.465.3500
FAX: 952.465.3501
EMAIL: cs@augsurg.com
www.hotdogwarming.com
HotDog Patient
Warming Mattresses
Instructions for Use
EU Authorized Representative:
NL-AR-000000116
TEL (31) (0) 70 345-8570
FAX (31) (0) 70 346-7299
MDR Importer:
MedEnvoy Global BV
Prinses Margrietplantsoen 33 – Suite 123
2595 AM The Hague
The Netherlands
NL-IM-000000248
TEL :+31 70 326 2148
1

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the HotDog U101 and is the answer not in the manual?

Questions and answers

Summary of Contents for Augustine Surgical HotDog U101

  • Page 1 HotDog Patient Warming Mattresses Models U1XX, U2XX and U3XX Instructions for Use Manufactured by: EU Authorized Representative: MDR Importer: Augustine Temperature Management 7656 West 78 Street MedEnvoy Global BV Bloomington, MN 55439 USA Prinses Margrietplantsoen 33 – Suite 123 TEL: 952.465.3500 2595 AM The Hague NL-AR-000000116 FAX: 952.465.3501...
  • Page 2: Device Description

    User Manual: HotDog Patient Warming Mattresses Page 2 DEVICE DESCRIPTION HotDog Warming Mattresses, including OR table pad and table pad overlays (U1XX, U2XX and U3XX) (“Warming Mattresses”) are components of the HotDog Temperature Management System (“System”) and can be used with HotDog Controller Models WC5X or WC77, Warming Mattresses provide under-body patient warming at a specified and uniform temperature.
  • Page 3 Page 3 Instructions for Use: HotDog Patient Warming Mattresses WARMING MATTRESS PRECAUTIONS  Use under the direct supervision of a clinician.  Monitor the patient’s vital signs regularly during warming according to institutional protocol. If vital sign instability occurs, notify the clinician. ...
  • Page 4: Care And Maintenance

    User Manual: HotDog Patient Warming Mattresses Page 4 4. Place a thin barrier over the entire surface of Warming Mattress. Note: For U300 in Trendelenburg positioning, the A30X WaffleGrip accessory functions as the thin barrier. Note: For U220 (Pediatric Warming Mattress) users. - U220 are intended for use with patients <...
  • Page 5: Cleaning - General

    Page 5 Instructions for Use: HotDog Patient Warming Mattresses  Do not spray cleaning solutions into the electrical connector.  Do not use cleaning or disinfection methods different from those recommended in the User Manual without first checking with an authorized service representative to ensure that the proposed methods will not damage the equipment.
  • Page 6: Definition Of Symbols

    User Manual: HotDog Patient Warming Mattresses Page 6 ALARMS All alarm conditions in the Controller are classified as Medium Priority Technical Alarms. If an alarm occurs, unplug the device to reset the Controller. Check the Warming Mattress and attempt to resolve the alarm. If Alarm Lights illuminate after a reset is performed, discontinue use and refer the system to Biomedical Engineering.