Heat Outdoors UMBRA Tulip Safety Instructions And Operation Manual

Mgo gas fire pit

Advertisement

Quick Links

UMBRA Tulip
MgO Gas Fire Pit
Safety Instructions and Operation Manual
901683
Heat Outdoors
Unit 9, Stort Valley Industrial Estate
Stansted Road, Bishop's Stortford
Hertfordshire, United Kingdom
CM23 2TU
www.heat-outdoors.co.uk
01279 466500
info@heat-outdoors.co.uk

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the UMBRA Tulip and is the answer not in the manual?

Questions and answers

Subscribe to Our Youtube Channel

Summary of Contents for Heat Outdoors UMBRA Tulip

  • Page 1 UMBRA Tulip MgO Gas Fire Pit Safety Instructions and Operation Manual 901683 Heat Outdoors www.heat-outdoors.co.uk Unit 9, Stort Valley Industrial Estate 01279 466500 Stansted Road, Bishop’s Stortford info@heat-outdoors.co.uk Hertfordshire, United Kingdom CM23 2TU...
  • Page 2: Table Of Contents

    Contents Warning . . . . . . . . . . . . . . . . . . . . . 3 Leakage Test .
  • Page 3: Warning

    Check the hose from the gas bottle to the unit has no splits - this can be done with soapy water to identify splits in the hose . If odour persist contact Heat Outdoors or a gas supplier . Warning...
  • Page 4: Leakage Test

    Leakage Test Gas connections on the appliance are leak tested prior to shipment . Possible mishandling of the appliance during shipment can damage the integrity of some parts . A complete gas leakage test must be performed again at the installation site . Please follow the procedure below for leakage test .
  • Page 5: Safety Precautions

    Safety Precautions • Performance and safety service of this heater should be performed annually by a qualified gas engineer. • Do not use the heater in a combustable atmosphere . • Do not store or use petrol or other flammable liquids in the heater unit. •...
  • Page 6: Installation

    Installation Important safety requirements: THIS APPLIANCE IS FOR OUTDOOR USE ONLY It is not recommended for this heater to be installed or used indoors, garages or any other enclosed area . DO NOT place articles on or against this appliance . DO NOT use or store flammable materials near this appliance.
  • Page 7: Technical Specifications

    Technical Specifications UMBRA Tulip MgO Gas Fire Pit 901683 ATTENTION: This appliance is fitted with a flexible gas rubber pipe and clamps that must be used; never use a different kind of either and always use according to the national regulations in force of the country of destination . These components should be periodically replaced, according to the date reported on the body of each of them, or according to the national regulations in force of the country of destination .
  • Page 8: Assembly Instructions

    Assembly Instructions Parts supplied: • Fire Pit (1pcs) • Lava Rocks (3kg) Assembly Instructions...
  • Page 9 This gas fire pit must be installed on a flat, stable surface away from combustable materials . Step 1 1. Remove fire pit and cylinder from the packaging. Place on a flat stable surface. Step 2 2. Place 3kg of lava rocks on and around the burner evenly .
  • Page 10: Connecting The Lpg Gas Cylinder

    Connecting the LPG Gas Cylinder Before assembly, make sure all packing material has been removed . Flexible gas rubber pipe (EN 1763-1) and clamps are supplied with this appliance and must be used. You need to acquire an LPG gas cylinder. We recommend using the Umbra Tank Cover with a 5kg gas bottle, however, any bottle size up to 13kg is suitable .
  • Page 11: Operation

    Operation Before igniting the appliance, perform the “Leakage Testing” in a well ventilated area (outdoors). On first use and after every LPG cylinder change, the appliance gas circuit must be purged of air before igniting! To do this, turn the control knob counter-clockwise to the ignition position and push and hold for 1 minute before attempting ignition .
  • Page 12: Replacing The Gas Cylinder

    To turn OFF the heater Turn appliance control knob clockwise up to “OFF” position. Turn the LPG cylinder valve to the “OFF” position. Allow the appliance to cool before moving it (at least 30 minutes) Re-lighting Turn control knob to “OFF” position. Wait at least 5 minutes, to let gas dissipate, before attempting re-light burner .
  • Page 13 Cleaning & maintenance To enjoy outstanding performance of your heater for years make sure you perform the following maintenance activities on a regular basis: • Keep exterior surfaces clean . • Use warm soapy water for cleaning. Never use flammable, corrosive or abrasive cleaners .
  • Page 14: Troubleshooting

    Troubleshooting Troubleshooting...
  • Page 15: Storage

    Storage Between uses: • Turn the control knob to “OFF” position. • Turn LPG cylinder to “OFF” position. • Store heater upright in an area sheltered away from weather conditions (such as rain, sleet, hail, snow). • If desired, cover heater to protect exterior surfaces and to help prevent dust and debris collecting in air passages .